Records from 2016 to 2026. Most recent: inspection, 20 January 2026.
Inspection history · 7
20 January 2026
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8290906
13 February 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7860262
2 March 2021
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7148365
28 February 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144131
23 February 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144730
20 September 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6270837
12 January 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5793307
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 28 February 2021
Resolved
Bulk carriers of 150 in length and upwards shall be fitted with a loading instrument capable of providing information on hull girder, shear forces and bending moments taking into account the recommendations adopted by the organization. PSCO noted no certificate of approval for loading software currently being used.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2021
Resolution: Satisfactory Class Report Received.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 February 2021
Resolved
In close proximity to the helideck the following fire fighting appliances shall be privded and stored near the means of access to that helideck; in addition to the requirements of regulation 10.10, two sets of fire-fighting outfits. PSCO noted 01 fire fighting outfit had multiple tears on jacket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2021
Resolution: Witnessed approve fire suit placed into service
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 20 September 2017
Resolved
CODE:0610 CITE:74SOLAS(14)III/20.2 ACTION:17ac BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. STERN LAUNCHED LIFEBOAT HAS EXCESSIVE STEERING FLUID LEAK FROM THE STEERING HYDRAULIC LINES MAKING PRIMARY STEERING INOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2017
Resolution: Class report recieved. New hose was fabricated and successfully tested. Steering fully functional on life boat.
Documentation › Logs/Records › Required Logbook Entries (Annex VI-Related)
Issued 20 September 2017
Resolved
CODE:2410 CITE:MARPOL VI/14.6 ACTION:10c THE DATE, TIME, AND POSITION OF THE SHIP WHEN ANY OIL CHANGEOVER OPERATION IS COMPLETED PRIOR TO ENTRY INTO ECA SHALL BE RECORDED IN SUCH LOGBOOK AS PRESCRIBED BY THE ADMIN. VESSEL DID NOT LOG DATE, TIME, OR POSITION AT COMPLETION OF THEIR CHANGEOVER.
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 20 September 2017
Resolution: VESSEL CORRECTED LOGBOOK PROCEDURE IN ORDER TO COINCIDE WITH SMS PROCEDURES AND CITED REGULATION. VESSEL ALSO EMAILED THE COMPANY TO BROADCAST RECTIFIED DEFICIENCY TO FLEET TO PREVENT FURTHER NONCOMPLIANCE. SEE ATTACHED DOCUMENTS.