MAURY USCG vessel records
← All vessels

GATOR BAIT

GATOR BAIT is a 2014 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in March 2026, along with 11 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 25 March 2026.

Built
2014
Last inspected
25 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1277859
Flag
UNITED STATES
Maury page id
psix-1277859

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

25 March 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8332251
24 March 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8098905
8 August 2024 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7977033
3 June 2024 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7926416
7 September 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7787253
11 April 2023 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7767752
9 August 2022 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7529214
9 March 2022 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7408786
10 September 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7323976
2 August 2021 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7275910
9 September 2020 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7044534
10 June 2019 COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6703110
5 September 2018 DAPI Audit · Examination of Repairs · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6545157
1 May 2018 Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6411377
9 April 2018 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6389638
21 September 2017 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6270987
14 August 2017 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6271009
23 May 2016 Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5908182
4 April 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5847467

Deficiency record · 11

02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 September 2020 Resolved
The scope of an annual inspection is the same as the inspection for certification required by 46 CFR 176.402. Fractured weldments noted IWO port & starboard gunwales @ bow/fwd seating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 31 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2020 Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Fractured wire mesh for seating support noted IWO aft row seating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 31 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2020 Resolved
Vessel required to be equipped with operable navigational lights. Existing all around white light was extinguished at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 31 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2020 Resolved
Vessel required to be equipped with ground tackle properly sized for vessel/route. Vessel is not equipped with any type of ground tackle (anchor, anchor chain, anchor line).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 31 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2019 Resolved
Protective guards are required to protect against an exposed hazard such as gears or rotating machinery as per 46 CFR 177.960. The wire mesh that surrounds the "cage" assembly or the main engine/propellor assembly was detached (isolated) from frame assembly. Temporary repairs are authorized through the 2019 operating season. Repairs shall be completed NLT 31DEC2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 31 March 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 September 2018 Resolved
Attending Inspector(s) identified fractured weldments IWO starboard (bow) gunwale decking. The affected area has been repaired previously.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 4 April 2019
Resolution: Attending Inspector verified repairs made IWO starboard gunwale decking @ bow.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 September 2018 Resolved
Crop/Renew fractured transom plating IWO starboard quarter @ waterline. Temporary repairs have been effected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 4 April 2019
Resolution: Attending Inspector verified repairs made IWO transom plating @ side shell (stbd).
Construction/Loadline › Hull › Hull Plating
Issued 1 May 2018 Resolved
Fractured weldment/plating noted IWO starboard quarter side shell/transom.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 May 2018
Resolution: Attending Inspector verified (via photos) repairs made IWO starboard side shell/transom weldments.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 September 2017 Resolved
Emergency instructions were not posted/carried on board.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified posting of emergency escape markings.
Lifesaving › Lifebuoys › Serviceable
Issued 21 September 2017 Resolved
Ring life buoy required replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified renewal of ring life buoy.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 September 2017 Resolved
Installed lifeline was improper (non-floating).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified carriage of proper type/lenght of water line.