Records from 2021 to 2023. Most recent: inspection, 18 October 2023.
Inspection history · 5
18 October 2023
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7810386
4 October 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7803532
7 February 2021
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7137047
27 January 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7131558
27 January 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7131576
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 18 October 2023
No resolution recorded
08108- An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position. PSCO observed 07 alarm faults on the UMS extension panel in engine control room and nav bridge.
SOLAS (2020) II-1/51.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2023 — due date passed with no resolution recorded
Resolution: Received Class(LR)stating that a condition of class was issued until 17 December 2023.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 18 October 2023
Resolved
08103-Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed 02 faults in fire panel.
SOLAS (2020) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2023
Resolved 19 October 2023
Resolution: Received class report (LR) stating that fault were due to disconnected in the emergency escape trunk.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 October 2023
Resolved
07126-Means shall be provided to control leaks of flammable liquids. PSCO observed running oil in purifier space 3rd deck, portside behind purifier in ceiling.
SOLAS (2020) II-2/4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2023
Resolved 19 October 2023
Resolution: Received class report (LR) stating that oil stains were clean, related piping examined and no leaks were found.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 18 October 2023
No resolution recorded
10101-All arrangements used for pilot transfer shall efficiently fulfil their purpose of enabling pilots to embark and disembark safely. PSCO observed small cracks in the corners of several steps, both port and starboard emarkation ladders. [name withheld] stated ladders are in defect list and awaiting repairs.
SOLAS (2020)V/23.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2023 — due date passed with no resolution recorded
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 18 October 2023
No resolution recorded
CG006-The Master or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods: Install and operate a Ballast Water Management System that has been approved by the Coast Guard. It was reported to the PSCO that the BWTS was inoperable.
33CFR151.2025 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 October 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 October 2023
Resolved
09210-Hydraulic power operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. PSCO observed approx. 100L of hydraulic oil in tank which is below the required 400L of hydraulic oil.
SOLAS (2020) II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 October 2023
Resolved 18 October 2023
Resolution: PSCO verified that hydraulic oil tank was filled to the appropiate level.