Inspection history · 19
16 May 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8137301
23 September 2024
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8023541
18 July 2024
Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7961011
30 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7816242
19 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7692476
9 December 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7620544
21 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7537499
15 July 2022
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7506949
21 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7317391
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110386
19 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7098090
31 August 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7047045
4 September 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6802764
31 October 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6571692
24 September 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6547405
7 November 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6302176
17 November 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6042872
19 September 2016
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6004565
13 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5853730
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 September 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Inspection of EPIRB found corrosion on circuit board at antenna connection. Vessel to have an authorized facility repair or replace. EPIRB tested satisfactory. 46 CFR 176.808 (b).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 23 September 2024
Resolution: Epirb was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024
Resolved
A vessel with a power driven main steering gear must be provided with a limit switch to stop the steering gear before it reaches the rudder stops. Rudder stop limit switches were installed but failed to stop steering gear before making contact with rudder stops. 46 CFR 182.610(f)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 17 October 2024
Resolution: Received video of steering system operation not making contact with rudder stops.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2020
Resolved
Ring life buoys shall be of first class workmanship and free from any defects materially affecting their appearance or serviceability; the plug on the ring life buoy was wasted. The ring life buoy was replaced prior to departure.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
Resolution: Replacement provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 September 2019
Resolved
Obtain navigation ball day shape.
Nav rules
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 19 September 2019
Resolution: VSL rep sent a photo of a new ball day shape on the VSL
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 September 2019
Resolved
Obtain two First-Aid kits. Have expired items.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 19 September 2019
Resolution: VSL rep sent a photo of new first aid kits on the VSL
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 September 2019
Resolved
Two ring life buoys need maintenance. One needs retroreflective tape and one needs white plug.
46 CFR 180.70/ 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 19 September 2019
Resolution: VSL rep sent photos of the new lifering buoys.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 October 2018
Resolved
Three emergency lights were burnt out in passenger accomodation spaces.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 October 2018
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2018
Resolved
Lifebuoys were discovered without proper vessel name markings.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 October 2018
Resolution: Lifebuoys were marked properly prior to the completion of the inspection.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 31 October 2018
Resolved
O.W.S. content meter calibration certificate on board was older than 5 year requirement. Obtain new calibration or replace the content meter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 October 2018
Resolution: Vessel representative replaced the content meter on board with a new content meter.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 31 October 2018
Resolved
Overboard discharge piping was discovered with a potential for bypassing the O.W.S. equipment on board. Install a check valve or three way valve to allow for testing but protect against bypassing the O.W.S.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 31 October 2018
Resolution: Vessel representative installed a check valve to protect against bypassing the O.W.S.