MAURY USCG vessel records Sign in
← All vessels

CHEMICAL DISTRIBUTOR

CHEMICAL DISTRIBUTOR is a 1999 tank ship. The Coast Guard has recorded 19 inspections since 2002, most recently in August 2016, along with 3 deficiencies and 9 operational controls.

Records from 2002 to 2016. Most recent: inspection, 11 August 2016.

Built
1999
Last inspected
11 August 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9209996 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MALTA
—
Maury page id
psix-1278

Inspections, by type

…with no type recorded11
Years with a record 5 calendar years (2002–2016)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3979 - Simplified, Net Ton
3979 - Convention (Subpart B), Net Ton
7228 - Simplified, Gross Ton
7228 - Convention (Subpart B), Gross Ton
122876 - Dead Weight, Ton
161069 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

11 August 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5969064
5 February 2010 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676070
5 February 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676343
5 February 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676650
10 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3449897
4 April 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3446103
4 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3448301
21 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3397455
6 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3387783
6 January 2009 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex II Examination · COC-CHEM Renew · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3387785
6 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3389683
5 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3389228
30 January 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2864077
17 January 2007 ISPS II Exam · Ballast Water Examination · MARPOL Annex II Examination · COC-CHEM Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2853478
16 January 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2853420
25 December 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1867518
19 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1677703
18 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1677575
29 August 2002 Tank Vessel Examination · Ballast Water Examination · Certificate of Compliance
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1668159

Deficiency record · 3

Engineering › Compressed Air System (control) › Valve
Issued 5 February 2010 Resolved
Air supply to timing piston was not sufficient to actuate combustion in cylinders 1 and 4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2010
Resolution: Received class report stating that the crew cleaned the pneumatic control system, dismantled and cleaned the air reducer for M/E control and air cylinders for reversing gear. Received CG2692.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 10 April 2009 Resolved
Vessel granted inbound deviation for inoperable speed and distance indicator.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2009
Resolved 10 April 2009
Resolution: Received class report giving them permission to operate without the above listed def until 30JUN09
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 6 January 2009 Resolved
Vessel has an INOP speed log.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2009
Resolved 7 January 2009
Resolution: Recieved class report giving 3 month exemption for inoperative speed log.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.