ARDMORE ENGINEER

ARDMORE ENGINEER is a 2014 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in September 2025, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 13 September 2025.

Built
2014
Last inspected
13 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9654787
1278307
Flag
MARSHALL ISLANDS
Maury page id
psix-1278307

Documentation record

Tonnage as PSIX records it30069 - Convention (Subpart B), Gross Ton
13738 - Convention (Subpart B), Net Ton
44999 - Dead Weight, Metric Ton
60563 - Displacement, Metric Ton
29993 - Regulatory (Subpart C or D), Gross Ton
13738 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

13 September 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8229353
16 July 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7958902
3 April 2023 COC-CHEM & TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7660522
13 April 2021 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7171947
3 April 2020 Administrative Inspection · COC-TVE Renew
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934029
19 January 2019 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6612514
24 December 2018 ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6601686
4 November 2018 COE-Dockside · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6573807
23 October 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6566739
16 July 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6481597
26 May 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6411957
3 February 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5805602

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 July 2024 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to this acceptable to the organization (IEC 60092-5021999). Three cable containment pipes, starboard side just forward of house, found without bonding straps, drain plugs removed. The cable pipe/junction boxes and house have an open means to allow cargo vapors to enter the pipe. 74SOLAS(20) II-1/45.11 60AC and prior to cargo ops
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 July 2024
Resolved 17 July 2024
Resolution: Resolved by satisfactory class report. See documents tab for more report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 July 2024 Resolved
Where the atmosphere in double-hull spaces cannot be reliably measures using flexible gas sampling lines/hose, such spaces shall be fitted with permanent gas sampling lines. Found 5P ballast tank fixed gas sampling line disconnected, a flexible hose is installed: the flow rate and vacuum capabilities are in question. 74SOLAS(20) II-2/4.5.7.2.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2024
Resolved 2 August 2024
Resolution: Received class report with misidentified line on vessel.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 16 July 2018 Resolved
Any ship of 10,000 GT and above shall be fitted with oil filtering equipment (which) will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. In addition, it shall be provided with alarm arrangements to indicated when this level cannot be maintained. The system shall also be provided with arrangement to ensure that any discharge of oily mixture is automatically stopped when the oil content of the effluent exceeds 15 ppm. Vessel self-reported that the onboard oily water separator is inoperable. MARPOL I/14.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 2 August 2018
Resolution: Vessel submitted Class [name withheld] stating that the OWS was tested in the presence of an attending surveyor with satisfactory results.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.