← All vessels
EL COQUI
Freight Ship · Ro-Ro Cargo Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named EL COQUI
EL COQUI is a 2018 freight ship. The Coast Guard has recorded 64 inspections since 2014, most recently in July 2026, along with 31 deficiencies — 2 with no resolution recorded —, 7 operational controls and 9 casualty investigations between 2018 and 2025.
Records from 2014 to 2026. Most recent: inspection, 16 July 2026.
- Built
- 2018
- Last inspected
- 16 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 31 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 9 investigations · 2018–2025
Identity
1272288
9721968 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDJ4838
1278328
Flag
UNITED STATES
367781630
Maury page id
psix-1278328
Inspections, by type
…with no type recorded16
…past their stated due date2
Years with a record
12 calendar years (2014–2026)
The 64 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Registered dimensions (L × B × D)689.6 ft × 105.8 ft × 59.1 ft
Registered tonnagegross 37,462 / net 11,339
ITC dimensions (L × B × D)689.6 ft × 105.8 ft × 59.1 ft
ITC tonnagegross 37,462 / net 11,339
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2018
Hull materialSteel
PropulsionCombination Types
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37462 - Convention (Subpart B), Gross Ton
11339 - Convention (Subpart B), Net Ton
11339 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ4838MMSI 367781630 · active · compulsorily equipped · granted 8 April 2017, expires 8 April 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 64
16 July 2026
ACP COI Oversight · Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8439385
29 April 2026
In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8358090
6 January 2026
In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8291164
8 November 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8265926
8 November 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8266213
24 October 2025
Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8258096
11 September 2025
MTSA/ISPS Verification · Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8231562
1 August 2025
Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8200012
25 April 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8120140
26 August 2024
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7989675
29 May 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7923186
31 January 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7862209
18 January 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7851312
15 January 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7849447
12 January 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7848826
9 January 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7846952
6 January 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7845874
6 January 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7845898
3 January 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7844686
2 January 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7844025
30 December 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7843631
28 November 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7831021
25 August 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7776743
10 July 2023
COI Inspection · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7726661
26 June 2023
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7726581
23 December 2022
Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7613372
6 November 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7594859
17 October 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7575650
2 October 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7570714
20 August 2021
Annual Inspection · ACP Annual Oversight · Underwater Inspection in lieu of Drydock
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7278905
7 July 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7254084
18 June 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7311994
12 January 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7124084
13 November 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7096478
21 August 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7039281
20 August 2020
ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7024940
10 August 2020
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7029989
6 July 2020
Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7017306
13 March 2020
Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6926099
19 November 2019
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6994350
15 November 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6870869
10 October 2019
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6831936
23 July 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6759558
19 July 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6755355
26 April 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6665136
20 February 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6631827
3 December 2018
ACP Additional Oversight – Risk Assessment · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6591448
3 December 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6604226
19 October 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6564492
5 October 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6555625
21 September 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6545648
7 September 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6534679
31 August 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6531502
27 August 2018
Administrative Inspection · MTSA/ISPS Verification · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6528195
24 August 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6521782
16 August 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6513616
16 August 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6513746
10 August 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6510810
3 August 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6502301
24 July 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6489627
23 July 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6488896
4 October 2017
Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281429
1 October 2015
Welding Related Inspections Qualification Testing · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5737931
10 March 2014
Initial Construction-Excluding Oversight · Construction Oversight · Initial Certification · ACP Handover Survey · Welding Related Inspections Qualification Testing · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4813603
Deficiency record · 31
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2025
Resolved
While inbound on the ST. Johns River, vsl had a cooling water line rupture on the MDE causing a loss of propulsion.
Vsl is require to make repairs/replace as need to the MDE cooling water system to the satisfaction of the attending marine inspector/ surveyor
Vsl will also be require to have tug assist out bound and the deficiency will be cleared once the vsl has proven operation to it's next port of call.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 August 2024
Resolved
An audible and visual alarm system to give a warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position.
Multiple airlocks audible and visual alarm were either inoperable or adjusted with a time delay.
"IGF CODE"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2024
Resolved
The maintenance manual should include maintenance procedures for all technical gas-related installations and should comply with the recommendations of the suppliers of the equipment.
Gas Maintenance Area; Gas Detector (6332) calibration sticker was expired and the wire was pulled from the gland.
"IGF CODE"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2024
Resolved
The maintenance manual should include maintenance procedures for all technical gas-related installations and should comply with the recommendations of the suppliers of the equipment.
Gas Maintenance Area; the two gas detectors in the M/E silencers A/B were in fault.
"IGF CODE"
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024
Resolved
The inspection and maintenance of electrical installations in explosion hazardous spaces should be performed in accordance with a recognized standard.
Electrical cable bands in the HP Pump room are missing on cable runs.
"IGF CODE"
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 January 2024
Resolved
Vessel failed to report echo depth sounder was non-operational. 33 CFR 160.206 and 164.53 (a)(b).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 November 2023
Resolved
Vessel failed to meet NOA submission time requirements upon entering the Port of Jacksonville, FL as per 33 CFR 160.212(a)(4).
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 July 2023
No resolution recorded
All automatically or remotely controlled or monitored vital systems musted be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. A number of the vessels Periodic Safety Test Procedures needs to be amended and/or removed; i.e. LNG Vent Mast & Hydrocarbon Gas Detectors, Local ESD Location (CCR vs ECR), etc. Once updated/removed, submitted to Class and USCG for approval.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 July 2023
Resolved
The arrangement for gas fuel storage and distribution and use should be such that the number and extent of hazardous areas is kept to a minimum. Tank connection #1 and #3 piping/valve insulation covering needs to be properly secured/installed.
CG-521 Policy No. 01-12, and MSC,285(86) 2.3.1
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 10 July 2023
No resolution recorded
Vessel Ballast Water Alternate Management System does not function as per design and needs to be repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 March 2023
Resolved
For container and general cargo spaces, the International Code for Fire Safety System (FSS Code) regarding the fixed CO2 system requires three control arrangements: one third, two thirds, and entire discharge. The vessels current arrangement/installation is full discharge only and must comply with the FSS Code that entry into force 01 July 2014.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2022
Resolved
GAS DETECTION FOR GAS PIPE DUCTS AND MACHINERY SPACES CONTAINING GAS-FUELLED ENGINES SHOULD BE CONTINUOUS WITHOUT DELAY. MI FOUND GAS DETECTOR IN MDE SILENCER IN FAULT AND CANNOT BE CLEARED. VESSEL PORHIBITED FROM OPERATING LNG ON MDE UNTIL FAULTS ARE RECTIFIED BY ATTENDING USCG MARINE INSPECTOR.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022
Resolved
ANY PERSONNEL THAT SHOULD CARRY OUT INSPECTIONS AND MAINTENANCE OF ELECTRICAL INSTALLATIONS AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN EXPLOSION HAZARDOUS SPACES SHOULD BE QUALIFIED PURSUANT TO IEC 60079-17, ITEM 4.2. MI NOTED NUMEROUS LOOSE FITTINGS IN HAZARDOUS AREAS ON ELECTRICAL EQUIPMENT THAT NEEDS TO BE RECTIFIED.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 12 January 2021
Resolved
The condition of the ship and it's equipment shall be maintained and conform with the provision of the present Covention. Received notification the the Oil Filtering Equipment (Oily Water Separator- OWS)was altered by installing a "Booster/Lift Pump (Capacity of 0 - 18m3)to assist with delivery of supply water from the Bilge Holding tank to the approved OWS (Capacity of 5m3) without prior approval. Vessel is prohibited from the use of "Booster/Lift Pump" installed with theapproved OWS in operation until plans are submitted, reviewed, and approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2020
Resolved
The gas piping system should be installed w/ sufficient flexibility. Arrangement for provision of the nessary flexibility should be demonstrated to maintain the integrity of the piping system in all foreseen service situations. #2LNG "C" type storage tank safety relief valve (Y5601) pilot
gas pipe fitting failed/cracked, causing the relief valve to open and release mathane to the atmosphere.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2020
Resolved
Ships shall be designed, constructed and maintained in compliance with the requirements of a classification society which is recognized by the Administration. It was reported by the vessel manager that the bow thruster has been taken out of service due to a cooling water leak, as well the vessel was experiencing an intermittent soft start problem, and that repair efforts are currently underway.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 August 2020
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural requirements of a classification society which is recognized by the Administration. A 9” fore/aft crack between FR82 and 83 has been reported in the MGO storage tank. Impacted tanks are MGO Storage Tank 415P and Ballast Tank 412P. Submit repair proposal for review and approval prior to repair work.
SOLAS 14 CONS. II-1/3-1 - a/c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2020
Resolved
No. 1 LNG High pressure pump bearing failed causing the the unit to be inoperable. Additional, a detailed repair proposal and timeline/s was required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2019
Resolved
Three VFD Controller for the aft deck winches are damage and needs to be repaired/replaced. (Conditon of Class)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2019
Resolved
W-1 mooring winch starboard side controller found not in order (directional switch) is to be repaired and tested/verified in working order.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2019
Resolved
#2 Fire/Bilge Pump Controller VFD damaged and needs to be repaired.replaceed, and tested. Currently Mfgr has allowed the use of a soft start controller (constant speed) until the VFD is re-installed.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 July 2019
Resolved
#1 Ballast water treatment system sustained electrical damage inside the control cabinet, is out of order, and locked/tagged out.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 30 August 2018
Resolved
09234- Vessel is required to stand a 3-watch section and was only standing a 2-man watch section within the engineering department.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 August 2018
Resolved
04114- When the EDG battery bank selector switch is shifted between banks it cause (07) breakers on the emergency SWBD to trip off-line.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 August 2018
Resolved
06199- All the permanently installed gas detectors fitted in the LNG vent piping for the tank room, compressor room, and all gas spaces are in continuous faults.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 August 2018
Resolved
06199- The #2 DFDG gas detector to the GVU needs to be replaced or calibrated.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 30 August 2018
Resolved
14104- The OWS was unable to prove proper operation.
02 - Structural Conditions › N/A - No Subsystem › Water level detectors on single hold cargo ships
Issued 30 August 2018
Resolved
02132- The two bilge level sensors under the propulsion shaft are in constant alarm state.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 August 2018
Resolved
07124- The fixed fire suppression system in the EDG space has wasted/cracked flexible hose connection on the CO2 cylinders.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2018
Resolved
09209- The cable leading to the j-box on the STBD/FWD side of the EDG space needs to be properly secured within the junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 August 2018
Resolved
13102- The #2 DFDG was unable to prove operation on the duel fuel LNG.
Casualty record · 9
16 August 2018Routine · role: Involved in a Marine Casualty · activity 6513616
16 August 2018Routine · role: Involved in a Marine Casualty · activity 6513746
3 December 2018Routine · role: Involved in a Marine Casualty · activity 6604226
20 February 2019Routine · role: Involved in a Marine Casualty · activity 6631827
23 July 2019Routine · role: Involved in a Marine Casualty · activity 6759558
21 August 2020Routine · role: Involved in a Marine Casualty · activity 7039281
2 October 2022Routine · role: Involved in a Marine Casualty · activity 7570714
6 November 2022Routine · role: Involved in a Marine Casualty · activity 7594859
8 November 2025Routine · role: Involved in a Marine Casualty · activity 8266213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.