MAURY USCG vessel records
← All vessels

EL COQUI

EL COQUI is a 2018 freight ship. The Coast Guard has recorded 62 inspections since 2017, most recently in July 2026, along with 31 deficiencies — 2 with no resolution recorded —, 7 operational controls and 9 casualty investigations between 2018 and 2025.

Records from 2017 to 2026. Most recent: inspection, 16 July 2026.

Built
2018
Last inspected
16 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9721968
WDJ4838
1278328
Flag
UNITED STATES
Maury page id
psix-1278328

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded16
…past their stated due date2
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)689.6 ft × 105.8 ft × 59.1 ft
Registered tonnagegross 37,462 / net 11,339
ITC dimensions (L × B × D)689.6 ft × 105.8 ft × 59.1 ft
ITC tonnagegross 37,462 / net 11,339
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2018
Hull materialSteel
PropulsionCombination Types
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37462 - Convention (Subpart B), Gross Ton
11339 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 62

16 July 2026 ACP COI Oversight · Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8439385
29 April 2026 In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8358090
6 January 2026 In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8291164
8 November 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8265926
8 November 2025 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8266213
24 October 2025 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8258096
11 September 2025 MTSA/ISPS Verification · Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8231562
1 August 2025 Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8200012
25 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8120140
26 August 2024 Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7989675
29 May 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7923186
31 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7862209
18 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7851312
15 January 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7849447
12 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7848826
9 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7846952
6 January 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7845874
6 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7845898
3 January 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7844686
2 January 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7844025
30 December 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7843631
28 November 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7831021
25 August 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7776743
10 July 2023 COI Inspection · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7726661
26 June 2023 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7726581
23 December 2022 Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7613372
6 November 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7594859
17 October 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7575650
2 October 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7570714
20 August 2021 Annual Inspection · ACP Annual Oversight · Underwater Inspection in lieu of Drydock
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7278905
7 July 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7254084
18 June 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7311994
12 January 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7124084
13 November 2020 Damage Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7096478
21 August 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7039281
20 August 2020 ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7024940
10 August 2020 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7029989
6 July 2020 Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7017306
13 March 2020 Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6926099
19 November 2019 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6994350
15 November 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6870869
10 October 2019 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6831936
23 July 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6759558
19 July 2019 Damage Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6755355
26 April 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6665136
20 February 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6631827
3 December 2018 ACP Additional Oversight – Risk Assessment · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6591448
3 December 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6604226
19 October 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6564492
5 October 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6555625
21 September 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6545648
7 September 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6534679
31 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6531502
27 August 2018 Administrative Inspection · MTSA/ISPS Verification · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6528195
24 August 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6521782
16 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6513616
16 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6513746
10 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6510810
3 August 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6502301
24 July 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6489627
23 July 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6488896
4 October 2017 Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281429

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2025 Resolved
While inbound on the ST. Johns River, vsl had a cooling water line rupture on the MDE causing a loss of propulsion. Vsl is require to make repairs/replace as need to the MDE cooling water system to the satisfaction of the attending marine inspector/ surveyor Vsl will also be require to have tug assist out bound and the deficiency will be cleared once the vsl has proven operation to it's next port of call.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 November 2025
Resolution: Vsl replace both mde cooling water/jacket water expansion joint (supply and return)and complete underway op test.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 August 2024 Resolved
An audible and visual alarm system to give a warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position. Multiple airlocks audible and visual alarm were either inoperable or adjusted with a time delay. "IGF CODE"
Action required: 705 - Other - as specified
Resolved 30 August 2024
Resolution: Verified proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2024 Resolved
The maintenance manual should include maintenance procedures for all technical gas-related installations and should comply with the recommendations of the suppliers of the equipment. Gas Maintenance Area; Gas Detector (6332) calibration sticker was expired and the wire was pulled from the gland. "IGF CODE"
Action required: 705 - Other - as specified
Resolved 30 August 2024
Resolution: Verified proper operation and calibration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2024 Resolved
The maintenance manual should include maintenance procedures for all technical gas-related installations and should comply with the recommendations of the suppliers of the equipment. Gas Maintenance Area; the two gas detectors in the M/E silencers A/B were in fault. "IGF CODE"
Action required: 705 - Other - as specified
Resolved 30 August 2024
Resolution: Verified proper operation of gas detectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024 Resolved
The inspection and maintenance of electrical installations in explosion hazardous spaces should be performed in accordance with a recognized standard. Electrical cable bands in the HP Pump room are missing on cable runs. "IGF CODE"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 August 2024
Resolution: Verfified proper cable retention devices installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 January 2024 Resolved
Vessel failed to report echo depth sounder was non-operational. 33 CFR 160.206 and 164.53 (a)(b).
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 3 June 2024
Resolution: Submitted DNV Survey
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 November 2023 Resolved
Vessel failed to meet NOA submission time requirements upon entering the Port of Jacksonville, FL as per 33 CFR 160.212(a)(4).
Action required: 705 - Other - as specified
Due 28 November 2023
Resolved 28 November 2023
Resolution: Enforcement action
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 July 2023 No resolution recorded
All automatically or remotely controlled or monitored vital systems musted be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. A number of the vessels Periodic Safety Test Procedures needs to be amended and/or removed; i.e. LNG Vent Mast & Hydrocarbon Gas Detectors, Local ESD Location (CCR vs ECR), etc. Once updated/removed, submitted to Class and USCG for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 July 2023 Resolved
The arrangement for gas fuel storage and distribution and use should be such that the number and extent of hazardous areas is kept to a minimum. Tank connection #1 and #3 piping/valve insulation covering needs to be properly secured/installed. CG-521 Policy No. 01-12, and MSC,285(86) 2.3.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2023
Resolved 25 August 2023
Resolution: DF Cleared.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 10 July 2023 No resolution recorded
Vessel Ballast Water Alternate Management System does not function as per design and needs to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 March 2023 Resolved
For container and general cargo spaces, the International Code for Fire Safety System (FSS Code) regarding the fixed CO2 system requires three control arrangements: one third, two thirds, and entire discharge. The vessels current arrangement/installation is full discharge only and must comply with the FSS Code that entry into force 01 July 2014.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2023
Resolved 30 March 2023
Resolution: Received DNV Survey Statement (CA) with a due date of 29 Jun 2023.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2022 Resolved
GAS DETECTION FOR GAS PIPE DUCTS AND MACHINERY SPACES CONTAINING GAS-FUELLED ENGINES SHOULD BE CONTINUOUS WITHOUT DELAY. MI FOUND GAS DETECTOR IN MDE SILENCER IN FAULT AND CANNOT BE CLEARED. VESSEL PORHIBITED FROM OPERATING LNG ON MDE UNTIL FAULTS ARE RECTIFIED BY ATTENDING USCG MARINE INSPECTOR.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 October 2022
Resolution: Gas detector renewed, calibrated, and demostrated satisfactory testing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022 Resolved
ANY PERSONNEL THAT SHOULD CARRY OUT INSPECTIONS AND MAINTENANCE OF ELECTRICAL INSTALLATIONS AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN EXPLOSION HAZARDOUS SPACES SHOULD BE QUALIFIED PURSUANT TO IEC 60079-17, ITEM 4.2. MI NOTED NUMEROUS LOOSE FITTINGS IN HAZARDOUS AREAS ON ELECTRICAL EQUIPMENT THAT NEEDS TO BE RECTIFIED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 7 November 2022
Resolution: A service report and Class survey report was provided to show items were repaired.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 12 January 2021 Resolved
The condition of the ship and it's equipment shall be maintained and conform with the provision of the present Covention. Received notification the the Oil Filtering Equipment (Oily Water Separator- OWS)was altered by installing a "Booster/Lift Pump (Capacity of 0 - 18m3)to assist with delivery of supply water from the Bilge Holding tank to the approved OWS (Capacity of 5m3) without prior approval. Vessel is prohibited from the use of "Booster/Lift Pump" installed with theapproved OWS in operation until plans are submitted, reviewed, and approved.
Action required: 705 - Other - as specified
Resolved 5 February 2021
Resolution: Received Condition of class as documentary proof
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2020 Resolved
The gas piping system should be installed w/ sufficient flexibility. Arrangement for provision of the nessary flexibility should be demonstrated to maintain the integrity of the piping system in all foreseen service situations. #2LNG "C" type storage tank safety relief valve (Y5601) pilot gas pipe fitting failed/cracked, causing the relief valve to open and release mathane to the atmosphere.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 16 November 2020
Resolved 16 November 2020
Resolution: Received notification that the issue was due a cracked fitting not the pipe as previous stated. Fitting was repaired, system tested and back in normal operation. DNV-GL and USCG accepts the statement of repair and photos as documentary proof to clear the
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2020 Resolved
Ships shall be designed, constructed and maintained in compliance with the requirements of a classification society which is recognized by the Administration. It was reported by the vessel manager that the bow thruster has been taken out of service due to a cooling water leak, as well the vessel was experiencing an intermittent soft start problem, and that repair efforts are currently underway.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 20 August 2020
Resolution: Refer to DNV-GL classification survey (Job Id: 1486768).
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 August 2020 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural requirements of a classification society which is recognized by the Administration. A 9” fore/aft crack between FR82 and 83 has been reported in the MGO storage tank. Impacted tanks are MGO Storage Tank 415P and Ballast Tank 412P. Submit repair proposal for review and approval prior to repair work. SOLAS 14 CONS. II-1/3-1 - a/c
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2020
Resolved 20 August 2020
Resolution: Refer to DNV-GL classification survey (Job Id: 1486768).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2020 Resolved
No. 1 LNG High pressure pump bearing failed causing the the unit to be inoperable. Additional, a detailed repair proposal and timeline/s was required.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 2 November 2020
Resolution: O/O provided objective evidence that the pump has been installed and is operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2019 Resolved
Three VFD Controller for the aft deck winches are damage and needs to be repaired/replaced. (Conditon of Class)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 2 August 2019
Resolution: Condition of Class
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2019 Resolved
W-1 mooring winch starboard side controller found not in order (directional switch) is to be repaired and tested/verified in working order.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 2 August 2019
Resolution: Condition of Class
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2019 Resolved
#2 Fire/Bilge Pump Controller VFD damaged and needs to be repaired.replaceed, and tested. Currently Mfgr has allowed the use of a soft start controller (constant speed) until the VFD is re-installed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 2 August 2019
Resolution: Condition of Class
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 July 2019 Resolved
#1 Ballast water treatment system sustained electrical damage inside the control cabinet, is out of order, and locked/tagged out.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 2 August 2019
Resolved 2 August 2019
Resolution: Condition of Class
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 30 August 2018 Resolved
09234- Vessel is required to stand a 3-watch section and was only standing a 2-man watch section within the engineering department.
Action required: 10 - Deficiency Rectified
Due 30 August 2018
Resolved 30 August 2018
Resolution: Master and [name withheld] corrected on the spot. Engineers are standing a 3-watch section.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 August 2018 Resolved
04114- When the EDG battery bank selector switch is shifted between banks it cause (07) breakers on the emergency SWBD to trip off-line.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 September 2018
Resolved 4 October 2018
Resolution: Received DNV-GL Class Survey Statement Job Id:1203616 attesting to the repair. USCG tested the system; ALL SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 August 2018 Resolved
06199- All the permanently installed gas detectors fitted in the LNG vent piping for the tank room, compressor room, and all gas spaces are in continuous faults.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2018
Resolved 2 May 2019
Resolution: Received DNV-GL Class Survey Statement Job ID: 1299638.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 August 2018 Resolved
06199- The #2 DFDG gas detector to the GVU needs to be replaced or calibrated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 4 October 2018
Resolution: Received DNV-GL Class Survey Statement Job Id:1203616 attesting to the repair.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 30 August 2018 Resolved
14104- The OWS was unable to prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 25 September 2018
Resolution: Received DNV-GL Class Survey Statement Job Id:1203616 attesting to the repair.
02 - Structural Conditions › N/A - No Subsystem › Water level detectors on single hold cargo ships
Issued 30 August 2018 Resolved
02132- The two bilge level sensors under the propulsion shaft are in constant alarm state.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 25 September 2018
Resolution: Received DNV-GL Class Survey Statement Job Id:1203616 attesting to the repair.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 August 2018 Resolved
07124- The fixed fire suppression system in the EDG space has wasted/cracked flexible hose connection on the CO2 cylinders.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 4 October 2018
Resolution: Received DNV-GL Class Survey Statement Job Id:1203616 attesting to the repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2018 Resolved
09209- The cable leading to the j-box on the STBD/FWD side of the EDG space needs to be properly secured within the junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 25 September 2018
Resolution: Received DNV-GL Class Survey Statement Job Id:1203616 attesting to the repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 August 2018 Resolved
13102- The #2 DFDG was unable to prove operation on the duel fuel LNG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 4 October 2018
Resolution: Received DNV-GL Class Survey Statement Job ID: 1203616.

Casualty record · 9

16 August 2018Routine · role: Involved in a Marine Casualty · activity 6513616
16 August 2018Routine · role: Involved in a Marine Casualty · activity 6513746
3 December 2018Routine · role: Involved in a Marine Casualty · activity 6604226
20 February 2019Routine · role: Involved in a Marine Casualty · activity 6631827
23 July 2019Routine · role: Involved in a Marine Casualty · activity 6759558
21 August 2020Routine · role: Involved in a Marine Casualty · activity 7039281
2 October 2022Routine · role: Involved in a Marine Casualty · activity 7570714
6 November 2022Routine · role: Involved in a Marine Casualty · activity 7594859
8 November 2025Routine · role: Involved in a Marine Casualty · activity 8266213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.