← All vessels
TAINO
Freight Ship · Ro-Ro Cargo Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named TAINO
TAINO is a 2018 freight ship. The Coast Guard has recorded 41 inspections since 2014, most recently in August 2025, along with 18 deficiencies — 3 with no resolution recorded —, 3 operational controls and 5 casualty investigations between 2019 and 2020.
Records from 2014 to 2025. Most recent: inspection, 19 August 2025.
- Built
- 2018
- Last inspected
- 19 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 3 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2019–2020
Identity
1272242
9721970 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDJ6598
1278329
Flag
UNITED STATES
367799380
Maury page id
psix-1278329
Inspections, by type
…with no type recorded7
…past their stated due date2
Years with a record
10 calendar years (2014–2025)
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Registered dimensions (L × B × D)689.6 ft × 105.8 ft × 59.1 ft
Registered tonnagegross 37,462 / net 11,339
ITC dimensions (L × B × D)689.6 ft × 105.8 ft × 59.1 ft
ITC tonnagegross 37,462 / net 11,339
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2018
Hull materialSteel
PropulsionDual Fuel (Diesel & Liquefied
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11339 - Convention (Subpart B), Net Ton
37462 - Convention (Subpart B), Gross Ton
37462 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ6598MMSI 367799380 · active · compulsorily equipped · granted 12 July 2017, expires 12 July 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 41
19 August 2025
Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8213137
12 August 2025
Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8208012
5 August 2025
Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8202779
29 July 2025
Packaged Hazmat Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8197289
2 July 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8173552
8 April 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8109574
17 March 2025
ACP COI Oversight · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8094743
29 May 2024
Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7923074
28 November 2023
COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7830412
16 March 2023
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7651405
13 January 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7621121
15 August 2022
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7534510
13 August 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7532237
3 May 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7444375
13 December 2021
Underwater Inspection in lieu of Drydock · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7364599
13 December 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7366026
2 March 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7148890
22 January 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7128956
12 January 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7124078
15 December 2020
ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7108831
7 December 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7107769
6 December 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7107404
24 November 2020
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7101309
24 November 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7104332
23 November 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7103774
16 November 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7098759
4 September 2020
ACP Additional Oversight – Risk Assessment
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7050127
4 September 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7050191
4 March 2020
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6920429
18 February 2020
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6913264
21 January 2020
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6885993
8 January 2020
Examination of Repairs · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6887076
26 November 2019
Construction Oversight · Administrative Inspection · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6862642
4 September 2019
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6805607
16 April 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6665133
27 February 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6633500
25 February 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6631642
7 January 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606544
22 October 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6570574
16 March 2016
In-Service Inspection · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5835089
10 March 2014
Examination of Repairs · Administrative Inspection · Initial Construction-Excluding Oversight · MTSA/ISPS Verification · ACP Handover Survey · Damage Survey · Construction Oversight · Welding Related Inspections Qualification Testing
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4813605
Deficiency record · 18
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2024
No resolution recorded
The storage tank used for liquefied gas should be an independent tank designed in accordance with the IGC code, Chapter 4.23.
The vessel Port Engineer notified the USCG of the presence of Methane in the annular space of the #1 LNG tank (15%-20% by volume).
Provide detailed repair proposal to USCG and Class for review.
Vessel is approved for bunkering into the #2 and #3 LNG tanks if conditions below are met.
1. Maintain LNG tank #1 isolation, as per approved plan.
2. Provide daily trend analysis of temperature, pressure and vacuum of LNG tank #1 to USCG Sector Jacksonville.
***Report any abnormal changes of tank conditions to local OCMI and/or Sector Jacksonville OCMI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2024
Resolved
The storage tank used for liquefied gas should be an independent tank designed IAW the IGC code chapter 4.23. USCG received notification that the present of Methane was detected in the annular space of the #1 LNG tank (15% - 20% by volume). Per the proposal received, #1 LNG tank must be gas freed (gas freed plan must be submitted) and a detailed troubleshooting method plan be submitted to USCG and class for review and approval. Additionally, #2 & #3 LNG tank annular spaces must be checked for the present of Methane.Vessel is prohibited from bunkering ops until this issue is resolved and/or prior approval from the OCMI.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 August 2024
Resolved
Gas piping should be protected against mechanical damage and capable of assimilating thermal expansion without developing substantial tension. Fracture ID'd ON 1/2" High High alarm piping of #1 LNG Tank Connection Space. Vessel is prohibited from LNG bunkering and the LNG tank must be gas-freed per Marine Chemist report. Additionally, a repair plan must be submitted and approved prior to commencement of any work or operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2024
No resolution recorded
Demonstrate proper installation/operation of the BOG conversion to include all safeties, proper labeling controllers/breakers, and satisfying all comments on Marine Safety Center letter dated 23 Jan 2024.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
Resolved
Gas pipes should be colour marked based on the recognized standard. Properly label all LNG piping throughout the system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
Resolved
Re-new and/or reinstall LNG piping and valve insulation coverings throughout the LNG system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
No resolution recorded
Update the PSTP tasks and steps for the BOG conversion and Gas Detector that were removed, etc.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
Resolved
Demonstrate proper operations of the LNG high pressure pumps and the newly installed oil sump motors to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
Resolved
Replace broken bracket for the CCTV at the port LNG bunkering station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
Resolved
Tank Connection Spaces (TCS) must maintain there Hazardous Area classification when the system is in operation. i.e. TCS door must be properly secured.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 March 2023
Resolved
For container and general cargo spaces, the International Code for Fire Safety System (FSS Code) regarding the fixed CO2 system requires three control arrangements: one third, two thirds, and entire discharge. The vessels current arrangement/installation is full discharge only and must comply with the FSS Code that entry into force 01 July 2014.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pollution report-MARPOL Annex I
Issued 12 January 2021
Resolved
Each operation shall be fully recorded in Oil Record Book Part I, so that all entries in the book appropriate to the operation are correct. A number of number of entries in the Oil Record Book are questionable for the OWS discharge overboard and training shall be provided on obtaining accurate tank sounding/entries.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 December 2020
Resolved
THE MASTER SHALL BE PROVIDED WITH APPROPRIATE INFORMATION ON THE CARGO SUFFICIENTLY IN ADVANCE OF LOADING TO ENABLE THE PRECAUTIONS WHICH MAY BE NECESSARY FOR PROPER STOWAGE AND SAFE CARRIAGE OF CARGO TO BE PUT INTO EFFECT. SUCH INFORMATION SHALL BE CONFIRMED IN WRITING OR ELECTRONIC DATA TECHNIQUES PRIOR TO LOADING THE CARGO ON THE SHIP. THE COMPANY DOES NOT PROVIDE THE CARGO WATCH OFFICER WITH A PREDETERMINED LOADING OR DISCHARGE PLAN CONFIRMED BY ALL INVOLVED PARTIES PRIOR TO THE TRANSFER OF CARGO. THIS IS A DIRECT CONTRIDICTION TO THE REQUIREMENTS SET FORTH WITHIN THE VESSELS SHIPBOARD SAFETY MANAGEMENT SYSTEM.
74SOLAS (14) VI/2.1
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 24 November 2020
Resolved
The accommodation provided for officers and crew on all vesseld must be securely constructed, ventilated and isulated from undue noise, heat and odors. USCG Marine Inspector received notification of a potential hazardous (CH4, H2S, CO, HS, etc.) condition existing in the following spaces (intermittently): Accommodation, Bridge, and Engine Control Room while U/W. The above mentioned odors are being emitted through the vesses vessel intakes (intermittently). Vessel/Company to provide a corrective action plan to resolve this issue.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 28 March 2019
Resolved
PRECAUTIONS SHALL BE TAKEN TO PROTECT HIGH TEMPERATURE SURFACES AND HIGH PRESSURE CONNECTIONS FROM BECOMING AN IGNITION SOURCE. MI IDENTIFIED NUMEROUS OIL SOAKED PIPE FLANGE PROTECTION LAGGING AROUND THE MAIN ENGINE.
14 SOLAS II/2/4.2.2.6.2
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 28 March 2019
Resolved
MAIN STEERING GEAR CIRCUIT PROTECTION MUST INCLUDE A THREE-PHASE SUPPLY. ALARM THAT WILL INDIICATE FAILURE OF ANY ONE OF THE SUPPLY PHASES. [name withheld] THAT THE #1 STEERING GEAR PUMP HAD AN INTERMITENT POWER FAILURE ALARM.
14 SOLAS II-1/30.3
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 March 2019
Resolved
REASONABLE MEASURES SHALL BE TAKEN TO LIMIT THE ENTRY AND SPREAD OF WATER THROUGH BULKHEAD MOUNTED VENTILATORS. [name withheld] THAT THE EMERGENCY GENERATOR VENTILATOR/LOUVER IS ALLOWING WATER INGRESS FROM THE ABOVE DECK WATER RUN-OFF WHEN FULLY CLOSED. 14 SOLAS II-1/16-1.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 March 2019
Resolved
MEASURES SHALL BE TAKEN TO ENSURE THAT EQUIPMENT IS FUNCTIONING AND MADE READY FOR REGULAR INSPECTIONS TO ENSURE RELIABLE OPERATION. MI IDENTIFIED THAT THE EMERGENCY FIRE PUMP DOES NOT OPERATE AS DESIGNED. ONCE STARTED THE HEATER CIRCUIT DOES NOT DE-ENERGIZE AND THE CONTROL PANEL DOES NOT DISPLAY PUMP HAS BEEN ENERGIZED. 14 SOLAS II-1/46.2
Casualty record · 5
25 February 2019Routine · role: Involved in a Marine Casualty · activity 6631642
23 November 2020Routine · role: Involved in a Marine Casualty · activity 7103774
24 November 2020Routine · role: Involved in a Marine Casualty · activity 7104332
6 December 2020Routine · role: Involved in a Marine Casualty · activity 7107404
7 December 2020Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7107769
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.