Records from 2016 to 2026. Most recent: inspection, 14 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2014
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portPINELAND, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 19 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
14 January 2026
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8290395
9 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8228682
25 April 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7896949
9 January 2024
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7846616
21 August 2023
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7771290
13 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576877
24 May 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7457068
21 January 2022
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7385439
29 July 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7270693
11 January 2021
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7122503
5 January 2021
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7119920
23 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6983838
16 January 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6888894
9 May 2019
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6680225
17 July 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6477552
9 January 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6332928
24 August 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6243481
14 September 2016
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5995095
19 January 2016
Hull Examination · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5791866
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 September 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
The vessel's EPRIB is still functional, and tested satisfactory. However, the EPIRB battery is expired.
Replace EPRIB battery or Replace EPIRB module and provide updated EPIRB NOAA Registration Confirmation Certificate to USCG Marine Inspector.
46CFR180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2025
Resolution: Verified installation of new EPIRB module and hydrostatic release. Tested EPIRB IAW MFR instructions. Received updated EPIRB NOAA Registration Confirmation Certificate, added new beacon ID to MISLE: 2DDAA F9FE3 3FDFF, expiration date 16SEP2027.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 August 2023
Resolved
The sound signal device (portable fog horn) is heavily
corroded. Replace sound signal device.
33CFR83.33
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 6 September 2023
Resolution: The sound signal device was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2023
Resolved
Fuel shutoff valves, installed so as to close against
the fuel flow, must be fitted in the fuel supply lines.
Port and starboard fuel shutoff valves are hard to shut,
and are missing handle securing hardware. The starboard
fuel shutoff valve handle is stripped. Replace both port
and starboard fuel shutoff valves.
46CFR182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2023
Resolved 6 September 2023
Resolution: Port and starboard fuel shutoff valves were replaced.
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2018
Resolved
Repair gel coat damage, port/starboard hulls.
Action required: 705 - Other - as specified
Resolved 29 January 2018
Resolution: Received emailed photos from vessel representative of completed repairs.
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2018
Resolved
Repair gel coat blisters, port/starboard hulls, and hull bottoms.
Action required: 705 - Other - as specified
Resolved 29 January 2018
Resolution: Received emailed photos from vessel representative of completed repairs.
Construction/Loadline › Structures › Deck Plating
Issued 9 January 2018
Resolved
Investigate extent of deck rot, starboard side, in way of stanchion housing speaker wire. Repair/replace.
Action required: 705 - Other - as specified
Resolved 29 January 2018
Resolution: Received emailed photos from vessel representative of completed repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2018
Resolved
Repair/replace torn canvas dodgers in way of port/starboard bemini ladders.
Action required: 705 - Other - as specified
Resolved 29 January 2018
Resolution: Received emailed photos from vessel representative of completed repairs.
Engineering › Gasoline (Outboard) › General
Issued 9 January 2018
Resolved
Port engine replaced in kind, conduct engine trial prior to dry dock credit being granted.
Action required: 705 - Other - as specified
Resolved 29 January 2018
Resolution: Engine trial of port engine witnessed by Coast Guard marine inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 September 2016
Resolved
Bilge high level does not provide audible or visual alarm, fix alarm at helm, DO not carry passengers until fixed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: Fixed alarm, power was not working.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 September 2016
Resolved
Hydrostatic release is expired, replace hydro.
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 28 September 2016
Resolution: Replaced hydro.
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2016
Resolved
Both port and stbd hulls have blisters between gelcoat and 1st layer of fiberglass and some spots into the 1st layer of laminate. Repair all spots identified during inspection, prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 8 February 2016