MAURY USCG vessel records
← All vessels

BOW TRAJECTORY

BOW TRAJECTORY is a 2014 tank ship. The Coast Guard has recorded 23 inspections since 2016, most recently in June 2026, along with 4 deficiencies and 8 operational controls.

Records from 2016 to 2026. Most recent: inspection, 25 June 2026.

Built
2014
Last inspected
25 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9669873
1278603
Flag
NORWAY
Maury page id
psix-1278603

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it61745 - Displacement, Metric Ton
49622 - Dead Weight, Metric Ton
30521 - Convention (Subpart B), Gross Ton
13352 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PHAETHON Tank Ship · MISLE 1047194 · 31 July 2017 · activity 6266569PORT ESTRELA Freight Ship · MISLE 1432124 · 31 July 2017 · activity 6266569

Inspection history · 23

25 June 2026 PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8413583
23 June 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8160047
16 June 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8160092
21 January 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8067046
10 January 2025 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8060854
19 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8037274
16 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8036398
19 September 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8005414
19 September 2024 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8005526
12 June 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7930275
21 April 2023 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7672810
22 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7435914
4 March 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405222
1 March 2022 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7403640
1 October 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7069317
20 September 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7060034
10 September 2019 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6799206
3 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6803591
29 October 2018 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6570203
10 August 2018 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6507320
31 July 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6266569
28 July 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6222544
19 July 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5943637

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 April 2023 Resolved
MEANS SHALL BE PROVIDED TO LIMIT THE ACCUMULATION OF FLAMMABLE VAPORS. IN NITROGEN GENERATOR SPACE, PSCO OBSERVED OXYGEN READINGINS ABOVE 22.5% AND CO2 READING EXCEEDING 75PPM. OXYGEN LEVELS CONTINUED TO INCREASE WHILE PLANT WAS IN OPERATION. 74 SOLAS (2020) II-2/4.1.2
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2023
Resolved 23 April 2023
Resolution: Marine Chemist certified space as safe for entry.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 21 April 2023 Resolved
OIL TANKERS...SHALL BE PROVIDED WITH A FIXED HYDROCARBON GAS DETECTION SYSTEM COMPLYING WITH THE F.S.S. CODE. HYDROCARBON GAS DETECTION SYSTEM WAS FOUND INOPERABLE SINCE APRIL 11, 2023. 74 SOLAS (2020) II-2/5.7.3.1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2023
Resolved 23 April 2023
Resolution: Vessel will test spaces weekly until parts are provided for repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2020 Resolved
13108 - Operation of machinery - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel reported that the #1 MDE start air compressor is inoperable. 74 SOLAS (14Cons) II-1/26.1 60 a/c
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2020
Resolution: Received attestation from master and pictures as objective evidence of rectification.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 28 July 2017 Resolved
A second source of energy shall be provided for an additional three starts within 30 minutes for each emergency generating set. On 27Jul17 ship's crew reported the #1 battery set failed upon testing the E-Gen. -SOLAS 74 am II-1/44 -17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2017
Resolved 30 July 2017
Resolution: 30JUL17: Received, reviewed and accepted class report from DNV-GL satisfying outstanding requirements related to the restriction.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.