MAURY USCG vessel records
← All vessels

HAFNIA TIGER

HAFNIA TIGER is a 2014 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in January 2026, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: operational control imposed, 2 January 2026.

Built
2014
Last inspected
2 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 January 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9635846
9V2554
1278920
Flag
SINGAPORE
Maury page id
psix-1278920

Documentation record

Tonnage as PSIX records it44999 - Dead Weight, Metric Ton
55812 - Displacement, Metric Ton
29752 - Convention (Subpart B), Gross Ton
11840 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

2 January 2026 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8289464
23 June 2025 COC-CHEM & TVE Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8160968
22 June 2025 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8163410
10 May 2025 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8132116
9 June 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7930171
4 June 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7927038
1 November 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7586961
5 July 2021 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7240265
21 June 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6981804
20 June 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6175790
13 June 2016 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5898387

Deficiency record · 2

Electrical › Electric Supply System (service) › Transformer
Issued 13 June 2016 Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards shall be ensured. There is unapprvoaed electrical installations supplying exercise equipment in the AC room. 74SOLAS(09 Cons)II-1/40.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 15 June 2016
Resolution: All exercise equipment (treadmill and stationary bike) were removed and sent to Gymnasium and all electrical connection including step-down transformer were removed. The areas now found satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 June 2016 Resolved
The fire resistance of doors shall be equivalent to division in which they are fitted. Fire resistant gaskets on upper deck stairwell and engine control room doors does not fit properly. 74SOLAS(04 Cons)II-2/9.4.2.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 15 June 2016
Resolution: Fire resistant gaskets were removed and re-fitted properly. Fire doors were tested and completely closing without any signs of leaks. The fire door sealing now found satisfactory.

Ownership record