MAURY USCG vessel records
← All vessels

NORTH OCEAN 102

NORTH OCEAN 102 is a 2009 offshore supply vessel. The Coast Guard has recorded 15 inspections since 2016, most recently in December 2023, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 21 December 2023.

Built
2009
Last inspected
21 December 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 December 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9382229
1279008
Flag
MALTA
Maury page id
psix-1279008

Documentation record

Tonnage as PSIX records it9055 - Dead Weight, Metric Ton
10000 - Displacement, Metric Ton
11680 - Convention (Subpart B), Gross Ton
3505 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

21 December 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841400
24 October 2023 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7808049
23 March 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7411654
15 March 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412083
4 November 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6847095
25 October 2019 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6842067
25 October 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6843576
11 January 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6607715
29 October 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6565974
25 October 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6567868
9 September 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6005250
8 September 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5992622
6 September 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5993223
10 June 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5903100
26 February 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5824965

Deficiency record · 6

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 November 2019 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended and shall be installed to reduce to a minimum any danger to persons on board. The vessel's starboard side azimuth thruster is inoperable. 74SOLAS(14)II-1/26.1 - 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2019
Resolved 8 November 2019
Resolution: Received classification report attesting to the repairs of the port thruster unit.
14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 4 November 2019 Resolved
The Garbage Record Book, whether as a part of the ship's official logbook or otherwise, shall be in the form specified in the appendix to this annex. Each completed page of the garbage record book shall be signed by the master. PSC Examiner witnessed multiple completed pages in the Garbage Record Book not signed by the master. MARPOL Annex V 10.3.1 - 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
Resolution: Deficiency cleared on site.
14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 4 November 2019 Resolved
The entry for each discharge to a port reception facility or another ship shall include the estimated amount discharged for each category in cubic meters. PSC examiners observed amounts discharged were not entered as cubic meters. MARPO Annex V 13.3.4 - 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
Resolution: Decficiency rectfied on site.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2018 Resolved
The fitting of fire detection as required by regulation 7.5.5.2 for the detection and extinction of fire in all spaces in which a fire might be expected to originate, generally with no restrictions on the type of internal divisional bulkheads. 74SOLAS(09)II-2/9.2.3.1.1.2. PSCO observed a smoke detection starboard side deck foreman office but not in the Port Side office. Both of these spaces contain space heaters (installed). Action taken 40ac.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 January 2019
Resolution: Verified that a new Smoke Detector was installed in the Portside Office. Tested the Smoke detector with artificial smoke to verify that it was in fact interlinked with the Alarm system. Verified that the Fire Control Plan was updated.
Navigation › Piloting/Steering › Notices to Navigation
Issued 8 September 2016 Resolved
1699/40ac: EVERY SHIP SHALL BE PROVIDED WITH A RECEIVER CAPABLE OF RECEIVING INTERNATIONAL NAVTEX SERVICE BROADCASTS. WHILE CONDUCTING AN EXAMINATION OF THE SHIP'S COMMUNICATION EQUIPMENT, THE CREW WAS UNABLE TO PROVE TO USCG PERSONNEL THAT NAVTEX IS OPERATIONAL.SOLAS(14)IV/7.1.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2018
Resolution: PSCO verified that the NAVTEX was operational as per SOLAS(14)IV/7.1.4.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 September 2016 Resolved
0696/40ac: MAINTENANCE, TESTING, AND INSPECTIONS OF LIFE-SAVING APPLIANCES SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION. VESSEL'S CREW HAS FAILED TO CONDUCT ROUTINE MAINTENANCE OF THEIR LIFE-SAVING APPLIANCES IN ACCORDANCE WITH THEIR APPROVED MAINTENANCE PLAN.SOLAS(14)III/20.3.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2018
Resolution: PSCO noted that the vessel's crew has conducted routine maintenance of life-saving appliances in accordance with approved maintenance plan. SOLAS(14)III/20.3.1.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.