01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 June 2022
No resolution recorded
M/V SEGAULA's annual inspection was due by June 23,2022. Vessel must satisfactorily complete an annual inspection prior to carrying passengers. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 March 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List. Light list, tide table and Coast Pilot needs to be updated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 10 May 2021
Resolution: Windows replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 24 March 2021
Resolved
Each deck where survival craft or rescue boats are stowed or boarded must be kept clear of obstructions that would interfere with the boarding of the survival craft. PS and STBD passenger hatches cannot be opened and secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 14 April 2021
Resolution: Hatch latch repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 March 2021
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 10 May 2021
Resolution: COI posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Sewage valve found inoperable. Exercise all thru hull valves.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2021
Resolved 10 May 2021
Resolution: valves serviced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 June 2020
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles must have on board a FCC Type Accepted Cat I, 406 MHz EPIRB. EBIRB battery expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 September 2020
Resolution: New EPIRB installed on vessel and info updated in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2020
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. Life jacket lights need batteries replaced.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: batteries installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 June 2020
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). STBD electric bilge pump not opertional.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: pump repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Nozzle missing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 September 2020
Resolution: nozzle installed.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 22 June 2020
Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Replace STBD operating station window.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020
Resolved 10 May 2021
Resolution: window replaced
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 June 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List. Light list and Coast Pilot needs to be updated.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: Light list and Coast Pilot installed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 June 2020
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast placard missing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: placard installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2020
Resolved
Sound device. Vessels horn not working. COLREG.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: horn repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2020
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: lifeline attached.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 22 June 2020
Resolved
Each deck where survival craft or rescue boats are stowed or boarded must be kept clear of obstructions that would interfere with the boarding of the survival craft. PS and STBD passenger hatches cannot be opened and secured.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2020
Resolution: hatches repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2020
No resolution recorded
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: vitial systems, interior lights, communications systems, navigation lights. The ship service generator is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2019
Resolved
All 3 B-II portable fire extinguishers needed to be serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: All portable fire extinguishers properly serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 April 2019
Resolved
Missing 6 hand red flares and 6 smoke flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: Vessel has provided appropriate number of approved flares required
Documentation › Logs/Records › Logbook (official)
Issued 23 March 2018
Resolved
Drills must be conducted each month and recorded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 25 July 2018
Resolution: Drills are being conducted and recorded.
Communications › Audible Communications › Horn/Whistle
Issued 23 March 2018
Resolved
Horn not working
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 25 July 2018
Resolution: Hormn properly working
Lifesaving › Lifebuoys › Serviceable
Issued 23 March 2018
Resolved
Life buoys are worn
Condition: Improper/Lack of Maintenance
Due 23 April 2018
Resolved 25 July 2018
Resolution: Life buoys replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 February 2018
Resolved
Vessel failed to conduct annual COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2018
Resolved 23 March 2018
Resolution: COI inspection conducted.
Engineering › Fuel Oil Service System › Pump
Issued 19 June 2017
Resolved
Prove proper operation of outboard engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 10 November 2017
Resolution: Repaired starboard outboard engine. Witness proper operation of engine.
Communications › Radio Communications › EPIRB
Issued 25 November 2016
Resolved
Provide current EPRIB registartion.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2016
Resolved 2 December 2016
Resolution: Vessel provided updated registyrtion for EPIRB.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 September 2016
Resolved
Provide a current certificate of documentation
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2016
Resolved 2 December 2016
Resolution: Provided current COD.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 September 2016
Resolved
Provide current servicing certificate.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2016
Resolved 6 January 2017
Resolution: Provided certificate.
Communications › Radio Communications › EPIRB
Issued 2 September 2016
Resolved
Provide current hydrostatic release for EPIRB.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2016
Resolved 6 January 2017
Resolution: Provided current hydrostatic release.
Fire Fighting › Nozzles › Number
Issued 2 September 2016
Resolved
Provide a proper nozzle for the fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2016
Resolved 6 January 2017
Resolution: Provided proper fire nozzle.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 September 2016
Resolved
Recharge/replace one BII fire extingisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2016
Resolved 6 January 2017
Resolution: Installed good ext.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 September 2016
Resolved
Replace lanyard on lifering bouy on upper deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 6 January 2017
Resolution: Replaced lanyard on life ring buoy.
Electrical › Electric Generation Source (service) › Generator
Issued 2 September 2016
Resolved
Repair generator automatic voltage regulator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 25 July 2018
Resolution: Took generator out of service and installed battery bank.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 August 2016
Resolved
Complete Hull Exam for credit dry dock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2016
Resolved 4 August 2016
Resolution: Hull exam complete. Outstanding work list items have been turned into CG-835's.
Stability › Freeing Ports › General
Issued 26 July 2016
Resolved
Vessel must repair the STBD FWD freeing port coverplate as original.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 November 2016
Resolution: Freeing port was rewelded.
Construction/Loadline › Hull › Weld
Issued 26 July 2016
Resolved
Repair stern rail / outboard protector as original / must call inspector to see fit-up.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 November 2016
Resolution: Repaired rails.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 26 July 2016
Resolved
Repair as original both Port and STBD Aft cleet.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 November 2016
Resolution: Cleats were replaced.
Stability › Watertight Integrity › General
Issued 26 July 2016
Resolved
replace in kind, overboard flapper
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 November 2016
Resolution: Overboard flapper was replaced.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 July 2016
Resolved
Attach safety lanyard to STBD FWD freeman hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Vessel attached lanyard to hatch.
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2016
Resolved
Remove sandbags from STBD side bilge. (sandbags blocking the flow to pump)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 4 August 2016
Resolution: Vessel removed sand bags.
Electrical › Electric Generation Source (service) › Generator
Issued 26 July 2016
Resolved
Clean oil and salt water from under generator, and repair saltwater pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Vessel cleaned under genset, but could not replace seal. Issued new deficiency for seal.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 July 2016
Resolved
repair sewage system as original.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 November 2016
Resolution: Sewage system was repaired.
Engineering › Bilge Water Management System › Valve
Issued 26 July 2016
Resolved
Make ready for inspection all seavalves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Inspected all sea vales, all sat.
Engineering › Sea-water System (primary cooling) › Pump
Issued 21 July 2016
Resolved
Replace saltwater pump seal as orginal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 November 2016
Resolution: Replaced saltwater pump.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 February 2016
Resolved
SPV Decal not posted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 February 2016
Resolved
Life raft (IBA) servicing certificates unavailable for review.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 February 2016
Resolved
Fire-servicing certificates unavailable for review.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Personnel › Certificates/Documents/Licenses › License, Master
Issued 4 February 2016
Resolved
Retain copies of Operator License onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 February 2016
Resolved
Retain copy of crew and passenger list onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Communications › Audible Communications › Horn/Whistle
Issued 4 February 2016
Resolved
Repair ship's whistle/horn.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 11 March 2016
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 4 February 2016
Resolved
Post no-smoking signs near gas stowage area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 11 March 2016
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 4 February 2016
Resolved
Post lifesaving placards near embarkation stations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 February 2016
Resolved
Must have 01 portable hand pump of 38 LPM (10GPM).
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 11 March 2016
Operations/Management › Drills/Instruction › Abandon Ship
Issued 4 February 2016
Resolved
Master must simulate broadcasting a mayday on VHF and provide vessel position, number of POB, and distress type.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2016
Resolved 26 April 2016
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 4 February 2016
Resolved
Repair clogged fuel intake to gas engines.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2016
Resolved 11 March 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 February 2016
Resolved
Conduct training with crewmembers on MOB recovery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2016
Resolved 26 April 2016
Operations/Management › Drills/Instruction › Fire
Issued 4 February 2016
Resolved
Conduct training with crewmembers on firefighting.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2016
Resolved 26 April 2016
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 3 February 2016
Resolved
Replace batteries in portable lights/flashlights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 February 2016
Resolved
Fire Extinguishers need to be serviced yearly IAW NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Fire Fighting › Fire Hoses › Length
Issued 3 February 2016
Resolved
Garden hose must be >25ft but <50ft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 January 2016
Resolved
Vessel must carry an adequate and up to date Coast Pilot to make navigation possible for the intended voyage.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 3 February 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 January 2016
Resolved
Vessel must carry adequate and up to date tide tables to make navigation possible for the intended voyage.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 3 February 2016
Navigation › Piloting/Steering › Marine Charts
Issued 19 January 2016
Resolved
Vessel must carry adequate and up to date charts to make navigation possible for the intended voyage.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 25 November 2016
Resolution: Vessel had charts.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 January 2016
Resolved
Vessel must carry an adequate and up to date light list to make navigation possible for the intended voyage.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 3 February 2016
Documentation › Logs/Records › Logbook (official)
Issued 19 January 2016
Resolved
The master does not maintain a logbook for recording abandon ship drills, fire drills, or man overboard drills. Provide a logbook with the drills required to be logged in accordance with 46CFR185.520 and 46CFR185.524.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 3 February 2016
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 January 2016
Resolved
Each crewmember, upon first being employed, shall be trained by either the owner or master to perform in an emergency situation including but not limited to the emergency instructions required by 185.510 and the duties listed in the station bill required by 185.514. Drills have not been conducted since 2014. New crewmembers shall be appropriately trained.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2016
Resolved 26 April 2016
Communications › Radio Communications › EPIRB
Issued 19 January 2016
Resolved
Each EPIRB must be tested monthly and each test must be logged. The monthly test on the EPIRB has never been conducted or logged.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 3 February 2016
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 January 2016
Resolved
The manufacturer's instructions for onboard maintenance of liferafts must be readily available. The owner shall make sure that monthly maintenance is carried out in accordance with the manufacturer instructions and the maintenance is logged or documented for the Coast Guard upon request. Manufacturer's instructions were not readily available and maintenance on the liferaft has not been conducted.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 25 November 2016
Resolution: Vessel implimented a maintainance log.
Engineering › Fuel Oil Service System › Hose
Issued 19 January 2016
Resolved
Gasoline engine delivery line flexible hose designed for use with hose clamps shall be installed with two clamps at both ends of the hose. Hose clamps on fuel delivery lines after the fuel filter were found without two hose clamps.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Engineering › Bilge Water Management System › Piping
Issued 19 January 2016
Resolved
Bilge pump overboard piping in the starboard forward space is severed next to the overboard valve and in need of repair. Repair the overboard bilge piping and install two hose clamps to secure.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016
Engineering › Fuel Oil Service System › Piping
Issued 19 January 2016
Resolved
Inspector witnessed corroded piping on the generator fuel/oil delivery lines. The cooling water line for the generator is leaking saltwater on the generator creating a corrosive environment. Repair generator delivery lines and saltwater delivery lines on generator.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 April 2016