← All vessels
MPC 924
MPC 924 is a 2014 tank barge. The Coast Guard has recorded 11 inspections since 2014, most recently in January 2024.
Records from 2014 to 2024. Most recent: inspection, 10 January 2024.
- Built
- 2014
- Last inspected
- 10 January 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 0 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1280033
Flag
UNITED STATES
—
Maury page id
psix-1280033
Inspections, by type
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
986 - Displacement, Net Ton
1619 - Simplified, Net Ton
986 - Displacement, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
10 January 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam · MTSA Verification · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7847540
7 September 2022
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7553420
20 August 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7038551
18 July 2019
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6754515
3 May 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6410385
7 July 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6201002
10 May 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5874304
29 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5865468
1 June 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5142297
24 March 2015
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5089445
15 April 2014
Hull Examination · Administrative Inspection · MTSA Verification · Drydock Exam · Internal Structural Exam · Cargo Tank Internal · Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4836525
Deficiency record · 0
No deficiencies recorded against this vessel. This means none were written in the records covered — it is not a statement about the vessel's condition. What a recorded resolution is.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.