Records from 2016 to 2025. Most recent: operational control imposed, 12 May 2025.
Inspection history · 25
12 May 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8132839
7 May 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8130274
30 April 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8124063
29 April 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8123260
27 January 2025
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069636
25 January 2025
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069802
16 May 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7912462
8 October 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7576283
7 October 2022
PSC C
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7573111
5 October 2020
Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7067035
3 October 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7070728
29 September 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7067756
18 January 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6611905
3 March 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6365160
2 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6364515
28 February 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6363665
8 February 2018
Administrative Inspection · In-Service Inspection · NPV Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6351710
5 February 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6349797
24 January 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6348563
14 July 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6201219
3 July 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6195579
15 December 2016
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6052112
27 May 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5885172
27 May 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5888519
26 May 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5887229
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 January 2019
Resolved
A fixed fire detection and fire detection and fire alarm system and a sample extraction smoke detection system required in this regulation and other regulations in this part shall be of an approved type and comply with the Fire Safety Systems code.
Flame detectors shall be tested according to standards EN 54-10:2001 and IEC 60092-504. Alternate testing standards may be used as determined by the administration. Vessel does not have appropriate means for testing the flame detectos onboard.
Action required: 15 - Rectify deficiencies by next port
Resolved 5 October 2020
Resolution: Completed satisfactory operational check of flame detectors with flame simulating light provided by vessel.
Lifesaving › Liferaft Equipment › Instructions (survival)
Issued 8 February 2018
Resolved
0620-Inflatable life raft-Cargo ships where the horizontal distance from the end of the stem or stern of the ship to the nearest end of the closest survival craft is more than 100m shall carry a life raft stowed as far forward or aft, as is reasonable and practicable. Due to marine casualty with a parting of mooring lines the six man life raft on the bow was destroyed and must be replaced. 74 SOLAS (14) III/31.1.4 60 a/c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2018
Resolution: A new liferaft was placed onboard.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 8 February 2018
Resolved
1320-Anchoring device-Prior to proceeding to sea, the master shall ensure that the intended voyage has been planned using the appropriate nautical charts and nautical publications for the area concerned taking into account the guidelines and recommendations developed by the organization. Due to line parting the STBD windlass electronic junction box is not operable and anchor could not be retrieved if dropped. 74 SOLAS (14) V/34 60 a/c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2018
Resolution: Anchor windlass was repaired.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 24 January 2018
Resolved
Vessels speed log is non operational, was granted an outbound LOD. 74 SOLAS (14) CH.V/Reg.19.2.2.3.4
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 27 May 2016
Resolved
Means of control shall be provided for opening and closure of openings in tunnels which normally allow exhaust ventilation and closure of ventilator dampers. The dampers on the port side of the EDG space would not close. SOLAS 2014 II-2 reg 5.2.2.1 (40BC)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 May 2016
Resolved 15 December 2016
Resolution: Means of securing dampners was installed. Def Check act#6052112 Sector Corpus Christi
Lifesaving › Lifeboat › Markings
Issued 27 May 2016
Resolved
Each lifeboat shall be fitted with a permanently affixed approval plate, endorse by the administration. The freefall lifeboat did not have a data plate. SOLAS 2014 III 34 / LSA 4.4.1.2 (40BC)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 May 2016
Resolved 15 December 2016
Resolution: Approval plate was on the inside of the life boat. Def check act# 6052112 Sector Corpus Christi