APL SOUTHAMPTON

APL SOUTHAMPTON is a freight ship. The Coast Guard has recorded 14 inspections since 2017, most recently in July 2025, along with 6 deficiencies and 3 operational controls.

Records from 2017 to 2025. Most recent: inspection, 29 July 2025.

Built
Not recorded
Last inspected
29 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9462017
9V9399
1280610
Flag
SINGAPORE
Maury page id
psix-1280610

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (2017–2025)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it174774 - Displacement, Metric Ton
135693 - Dead Weight, Metric Ton
128929 - Convention (Subpart B), Gross Ton
72397 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 14

29 July 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192840
3 December 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7832779
24 January 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7626144
17 September 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7314696
12 April 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173641
8 April 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7172019
25 March 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7163071
9 November 2020 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7092245
3 October 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070680
3 October 2020 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7075831
18 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7009403
16 May 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6954249
9 January 2019 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6605241
8 October 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6280710

Deficiency record · 6

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 April 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the number and nature of the deficiencies found during the PSC exam, there are clear grounds for believing that the SMS is not being implemented properly, is not covering essential equipment installed on ship, and is resulting in substandard conditions. PSCO identified numerous deficiencies in SMS relating to M/E cylinder pressure indicating cock installed on M/E, the procedures for cleaning and inspecting auxiliary boiler. ISM audit recommended. 74 SOLAS (20) IX/3.1 , ISM Code A/10.1 50bc
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 25 April 2021
Resolution: Master sent copy of ISM Audit and Notification of Noncomformity for vessel. Deficiency req'ts completed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 April 2021 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection. PSCO observed damaged fire insulation in vicinity of auxiliary boiler. 74 SOLAS (20) II-2/14.2.1.1.1 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2021
Resolution: Deficiency rectified to the satisfaction of class. See attached report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2021 Resolved
The condition of the ship and its associated equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noticed excessive leaking from jacket water cooling piping in engine room. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2021
Resolution: Deficiency rectified to the satisfaction of class. See attached report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 12 April 2021 Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirements: procedures to prepare for and respond to emergency situations. PSCO observed objective evidence that Master declared Chief Engineer (C/E) to be injured with "third degree" burns after an accident with the auxiliary boiler. Master sent detailed pictures to company medical representative regarding C/E injuries; burns to body and head. Master asked company if an expedited medical evacuation was necessary, company medical representative stated that the problem was not urgent. Later, the company determined that the C/E's injuries were severe enough that he would be unfit for duties while at sea; however, company did not expedite C/E's evacuation off of vessel. Company response does not align w/ severity of C/E's injuries, and demonstrates lack of effectiveness of implementation of ISM Code. Recommend external ISM audit for company, in addition to the previously recommended ISM audit of APL SOUTHAMPTON. 74SOLAS(20)IX/3.1 , ISM PART A/1.4.5 , 50bc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 10 May 2021
Resolution: Master sent copy of ISM Audit and Notification of Noncomformity for vessel. Deficiency req'ts completed.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 25 March 2021 Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into U.S. Waters.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 April 2021
Resolution: RECIEVED TECH REPORT ATTESTING TO THE REPAIR OF THE BALLAST WATER SYSTEM.
Engineering › Steering Gear System › Hand Pump
Issued 8 October 2017 Resolved
The steering gear is not operational on the bridge in hand steering mode nor at the steering gear in local mode
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2017
Resolved 9 October 2017
Resolution: Received satisfactory survey report from DNV GL attesting to operational status of steering gear.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.