Records from 2014 to 2025. Most recent: inspection, 13 September 2025.
Inspection history · 14
13 September 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8233597
18 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7537257
16 February 2022
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7397452
30 November 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7393014
17 November 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7353076
29 March 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7164521
6 January 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7120565
27 January 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6896641
7 July 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6729439
9 November 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6578339
29 April 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6396184
21 December 2016
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6060816
4 October 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6016033
19 June 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4881282
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 17 November 2021
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into U.S. Waters.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2022
Resolution: Received Tech report for BWTS repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2021
Resolved
BWM RELATED-BWMS system onboard was found to be inoperable.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2022
Resolution: Received Tech report for BWTS repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2018
Resolved
46CFR 151.2025 (a) (1) After installation of a ballast water management system, the vessel Master, owner, operator, agent or person in charge must properly maintain the system in accordance with all manufacturer specifications. The vessel is past their required BWMS compliance date and reported a failure of their approved ballast water management system.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2018
Resolution: Technician report received as requested by the Coast Guard attesting the BWMS is again working. Case closed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 October 2016
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use; and fire protection systems and fire fighting appliances shall be properly tested and inspected after servicing. CO2 bottles #11-20 discharge hoses were were not properly secured to the bottles. deficiency corrected on the spot to the satisfaction of the coast guard. -74SOLAS(2014)II-2 14.1
Condition: Improper Installation
Due 5 October 2016
Resolved 5 October 2016
Resolution: [name withheld] THE HOSES COMING FROM THE BOTTLES. CORRECTED ON THE SPOT