MAURY USCG vessel records Sign in
← All vessels

KYPROS SEA

KYPROS SEA is a 2014 freight ship. The Coast Guard has recorded 7 inspections since 2014, most recently in August 2024, along with 4 deficiencies.

Records from 2014 to 2024. Most recent: inspection, 26 August 2024.

Built
2014
Last inspected
26 August 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9675602 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1280729
Flag
CYPRUS
—
Maury page id
psix-1280729

Inspections, by type

Years with a record 6 calendar years (2014–2024)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it40872 - Convention (Subpart B), Gross Ton
77128 - Dead Weight, Metric Ton
89516 - Displacement, Metric Ton
26092 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

26 August 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7975262
25 October 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7573657
18 October 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7592825
20 October 2020 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7077530
21 July 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6479996
9 March 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6094885
19 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4860279

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 October 2022 Resolved
When the pump is delivering the quantiy of water required by paragraph 2.2.1.1, The pressure at any hydrants shall not be less than the minimum pressure required by chapter II-2. PSCO observed insufficient volume and pressure from two fire hoses. Hoses produced stream of water measuring two feet. SOLAS 74(am), II-2/10.2.2.3.1.2, FSS Code CH: 12.2.2.1.2. 10c
Action required: 10 - Deficiency Rectified
Due 25 October 2022
Resolved 25 October 2022
Resolution: Vessel was able to energize emergency fire pump and test was conducted IAW normal procedures
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2022 Resolved
All steering gear componenets and the rudder stock shall be of sound and reliable constriction to the satisfaction of the administration. PSCO observed several hydraulic leaks on both steering pumps. SOLAS 74(am), II-1/29.2.1
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2022
Resolved 26 October 2022
Resolution: Received satisfactory class report confirming suspected connections were opened, examined, cleaned, and reconnected for a satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 October 2022 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed a steady water leak on the general service (port side) pump. SOLAS 74(am), II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2022
Resolved 26 October 2022
Resolution: Received LR class report confirming packing gland was renewed and tightened accordingly. The GS pump was tested satisfactorily.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 19 May 2014 Resolved
0735-On all ships, within the machinery spaces, emergency escape breathing devices shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of fire. Vessel's EEBD's are not primed and ready for immediate use. 74SOLAS(09) II-2/14.4.3.1 (17c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 20 May 2014
Resolution: Received satisfactory Technician Report #17488 from GLOBAL FIRE & SAFETY attesting to inspection and priming of 09 EEBD''s onboard and ready for immediate use.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.