HAFNIA JAGUAR is a 2014 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in July 2025, along with 5 deficiencies and 6 operational controls, 1 with no removal date recorded.
Records from 2016 to 2025. Most recent: inspection, 10 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13740 - Convention (Subpart B), Net Ton 55754 - Displacement, Metric Ton 49999 - Dead Weight, Metric Ton 29737 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
74 SOLAS (2014) II-1/29.1
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Adminstration. The main steering gear and the auxiliary steering gear shall be so arrnaged that the failure of one of them will not render the other one inoperative. When conducting steering test with only the #1 steering pump online, the #1 steering pump breaker tripped on multiple tests.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 July 2019
Resolution: Class report received attesting to satisfactory repairs.
74 SOLAS (2014) II-1/29.1
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Adminstration. The main steering gear and the auxiliary steering gear shall be so arrnaged that the failure of one of them will not render the other one inoperative. When testing the low-low hydraulic level alarm on the #1 steering pump, the #1 steering pump does not shut down and the #2 steering pump does not automatically start.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 July 2019
Resolution: Class report received attesting to satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 July 2019Resolved
74 SOLAS (2014) I/11(b)
After any survey of the ship under regulations 7,8,9,or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The port side lifeboat does not have documentation from classification society approving patch repair on the starboard quarter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2019
Resolution: Class report received attesting to satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 15 July 2019Resolved
74 SOLAS (2014) II-2/5.5.1.1
FSS Code 15.2.2.1.3
For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. The systems shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume in the inert gas supply main to the cargo tanks at any required rate of flow. Crew was unable to calibrate O2 analyzer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2019
Resolution: Class report received attesting to satisfactory repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 July 2019Resolved
33 CFR 39.2001(j)
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7mm diameter and is at least 25.4mm long. The stud was able to be removed by hand.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2019
Resolution: Class report received attesting to satisfactory repairs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.