Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it41748 - Displacement, Ton 32352 - Dead Weight, Ton 20969 - Convention (Subpart B), Gross Ton 11795 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
0750-Fire Prevention-Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leakage from #1 & #3 auxiliary engins IWO turbo charger oil lubricated bearing supply flanges, and pooling on engine body and in catchment. SOLAS 74 (14) a II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 March 2018
Resolution: Received class report from LR stating all outstanding deficiency has been rectified. The class report stated: Crew changed damaged gaskets and thoroughly cleaned to the satisfaction of Surveyor.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 10 March 2018Resolved
0750-Fire Prevention-Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leakage from sludge tank (for incinerator) delivery pump mechanical seal failure, and non-approved containment that was full of FO. SOLAS 74 (14) a II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 March 2018
Resolution: Received class report from LR stating all outstanding deficiency has been rectified. The class report stated: Crew changed repaired mechanical seal and thoroughly cleaned to the satisfaction of Surveyor.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.