MAURY USCG vessel records
← All vessels

GOOD HEART

GOOD HEART is a freight ship. The Coast Guard has recorded 7 inspections since 2017, most recently in April 2023, along with 16 deficiencies and 2 operational controls.

Records from 2017 to 2023. Most recent: operational control imposed, 1 May 2023.

Built
Not recorded
Last inspected
29 April 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9669380
1281816
Flag
LIBERIA
Maury page id
psix-1281816

Documentation record

Tonnage as PSIX records it62996 - Dead Weight, Metric Ton
75094 - Displacement, Metric Ton
36354 - Convention (Subpart B), Gross Ton
21286 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

29 April 2023 MARPOL Annex I Examination · Deficiency Check · In-Service Inspection · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7677816
29 April 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7678707
11 July 2022 COE-Dockside · PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7491835
10 July 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7491788
1 July 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7492619
24 October 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6834858
23 January 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6070710

Deficiency record · 16

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 April 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO observed the following Safety Management System violations: Vessel engineering crew could not provide tank sounding logs readily upon request. Vessel crew could not provide a log for vessel security seals for valves and piping. Vessel engineering crew could not provide a satisfactory answer to the accumulation of oily water in the keel duct. Vessel engineering crew removed lockouts and seals on BGV-13 Bilge Water Overboard Valve. Ballast Water remote valves were completely removed from the piping system and makeshift means were installed for manual operation; the valves were unable to be operated via remote means. Vessel could not provide satisfactory logs or records of fire, smoke and bilge alarms since 20 March 2023. An external audit into the vessel's safety management system will be required. 74 SOLAS (20) IX ISM 10.1
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 27 May 2023
Resolution: Completed ISM Audit and satisfactory repairs/maintencance/housekeeping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 29 April 2023 Resolved
In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapours. PSCO observed oil dripping from STBD side lowest level overhead in engine room. Lagging around the piping was also found to be soaked in oil. - 74 SOLAS (20)II-2/4.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: oil soaked lagging renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 April 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed rescue boat would start but would not remain running. Additionally, the starboard deck ring life buoy was found to have an unattached and inoperable light. Cleared on 29APR2023
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2023
Resolution: Crew repaired Rescue Boat Engine and replaced Ring Bouy Light
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 29 April 2023 Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such a way that the accummulation of liquids is detected at normal angles of trim and heel. PSCO tested all four high water level bilge alarms in the engine room, and all were found to be inoperable. 74 SOLAS (20) II-1/48.1
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 27 May 2023
Resolution: bilge alarms repaired and tested sat by class and USCG.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 April 2023 Resolved
Means shall be provided to detect and give alarms at an early state in case of fires. PSCO observed a smoke detector above the diesel purifier to be covered with a rag, after testing multiple smoke and flame detectors, the entire system could not be acknowledged or reset from the main engine control room control panel. Each individual smoke and flame detectors needed to be removed from their respective mounts in order to be reset. Vessel engineering crew could not provide satisfactory instruction nor procedures for the current operational state of the fire alarm system. 74 SOLAS (20) II-1/47.1
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 27 May 2023
Resolution: crew removed rag from detector and conducted detector testing training; tested sat for Fire Protection Services Inc, class, and USCG.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 29 April 2023 Resolved
In the circumstances given in paragraph 1 of this regulation, the Party shall take such steps as will ensure that the ship shall not sail until the situation has been brought to order in accordance with the requirements of this Annex. PSCO observed excessive accumulation of oily water in the keel duct measuring approximately 39.5 centimeters. MARPOL ANNEX I REG.11.2
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 27 May 2023
Resolution: Pipe Tunnel was pumped of oily wastes, cleaned, and oil and water leaks repaired.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 29 April 2023 Resolved
An engineer's alarm shall be provided to be operated from the engine control room or at the maneuvering platform as appropriate, and shall be clearly audible in the engineers accommodation. Engineer's alarm system is malfunctioning and consistently producing all alarms without audible means since 20 March 2023. 74 SOLAS (20) II-1/28
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 27 May 2023
Resolution: Technicians replaced 6 PLCs; system tested sat for class and USCG.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 29 April 2023 Resolved
Install and operate a ballast water management system that has been approved by the Coast Guard. PSCO observed inoperable flow meter after ballast water filters. Vessel crew could not provide satisfactory operation of the ballast water treatment system. 33 CFR 151.2025(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: Crew cleaned #2 filter; tech rep attended and tested system sat at 50% flow rate. Flow meter needs to be replaced but system works in ballast and de-ballast modes at 50% flow rate. New flowmeter on order.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 April 2023 Resolved
Means shall be provided to limit the accumulation of flammable vapours. PSCO observed multiple locations throughout the engine room that had makeshift catch pans that were accumulating fuel oil. #1 generator was found with a rag blocking the fuel drain line; buckets were found under the fuel accumulation tank from the vessel's three generator's drain lines. All three generators have rags in the fuel filter drip trays. Bilge wells have excessive dirty oil accumulation. 74 SOLAS (20) II-2/4.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: oil accumulation cleaned.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 April 2023 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel leaks coming from the #1 and #2 generator valve cover area, Fuel purifier for Diesel fuel, and the main engine. Additionally, there was an excessive oil leak near the engine control room rear entrance. 74 SOLAS (20) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: leaks repaired and oil/fuel cleaned
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2023 Resolved
Cylinders must always be secured, and when not in use, they must be stowed in a rack in an upright position, with valve protection cap in place. PSCO observed all oxy-acetylene bottles tied in place. Proper brackets were nearby and not utilized. 46 CFR 147.60(b)(1) Cleared on 30APR2023
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2023
Resolution: Crew replaced with proper mounts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2023 Resolved
Except as permitted by the Administration in exceptional circumstances, all metal sheaths and armor of cables shall be electrically continuous and all be earthed. PSCO observed multiple electrical bonding cables missing for electrical conduits. - 74 SOLAS (20)II-1/45.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: bonding cables renewed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2023 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed multiple grounding cables missing for deck junction boxes and crew control panels for deck equipment. - 74 SOLAS (20)II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: grounding cables renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2023 Resolved
In cargo ships, the failure of such gauges or overfilling of tank shall not permit release of fuel into the space. PSCO observed MGO day tank/service tank sight glass with a steady drip and large accumulation of fuel beneath the sight glass. - 74 SOLAS (20)II-2/4.2.2.3.5.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: sight glass O rings replaced; all sat
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 29 April 2023 Resolved
The connection shall be kept aboard the ship together with a gasket with any material suitable for 1 N/mm2 services, together with four bolts of 16mm diameter and 50mm in length, four 16mm nuts and eight washers. PSCO observed starboard side international shore connection missing eight washers. -74 SOLAS (20) II-2/10.2.1.7.1 / FSS 2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: washers replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 29 April 2023 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed ballast Water remote valves were completely removed from the piping system, means were installed for manual operation; A socket wire tired to the valve stem welded to a breaker bar held one of the two valves close/open by a screwdriver wedged into another valve and the other wire tired to another pipe. The valves were unable to be operated via remote means. - 74 SOLAS (20)I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2023
Resolution: ROVs repaired and tested sat for class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.