CLARICE is a 2014 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in April 2025, along with 3 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 23 April 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25926 - Dead Weight, Metric Ton 32787 - Displacement, Metric Ton 14750 - Convention (Subpart B), Gross Ton 7993 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
23 April 2025Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8117857
5 March 2025PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8084855
26 February 2025Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8085130
14 November 2023COC-CHEM Renew · Administrative Inspection · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7821334
26 June 2018Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6456941
13 June 2018COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6438001
8 June 2018Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6484484
18 July 2017Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code. Cargo tanks shall be fitted with a visual and audible high-level alarm. No 6(s) cargo tanks high level alarm did not function in CCR or cargo deck area. This must be rectified prior to loading cargo that requires the alarm.
74 SOLAS VII/10.1
IBC 15.19.6 CODE:
ac
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 May 2025
Resolved 25 March 2025
Resolution: PSC NOLA received a class report documentation from NKK satisfying the requirement.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2025Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code. A tank over-flow control system shall give a visual and audible tank over-flow alarm. No 6(s) cargo tank over-flow alarm did not function on the cargo deck area.
74 SOLAS VII/10.1
IBC 15.19.7.2
CODE: 10c
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 5 May 2025
Resolved 5 March 2025
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 14 November 2023Resolved
SHIP SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTUAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. BALLAST WATER TREATMENT SYSTEM INOPERABLE.
74SOLAS(14) CH II-1 REG 3-1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2023
Resolved 26 February 2025
Resolution: PSC NOLA received a CLASS REPORT from Nippon Kaiji Kyokai satisfying the requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.