Records from 2005 to 2026. Most recent: inspection, 15 April 2026.
Inspection history · 42
15 April 2026
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8340376
6 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264871
9 May 2025
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8131588
22 July 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7965142
21 August 2023
Internal Structural Exam · Drydock Exam · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7773090
18 August 2023
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7771160
6 July 2023
Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7734986
31 May 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7464080
25 May 2022
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7452005
23 March 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7416644
12 November 2021
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7349594
22 April 2021
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7171265
14 October 2020
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7077977
13 October 2020
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7078207
20 July 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007802
6 January 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7011266
1 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6825657
1 August 2019
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6769302
23 July 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6719838
2 July 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6464130
17 January 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339355
12 July 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5944577
25 April 2016
Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5862143
6 April 2016
Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5848407
17 December 2015
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5782323
8 October 2015
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5738694
26 September 2015
Damage Survey · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5746176
29 July 2011
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4098562
24 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3654940
28 July 2009
Administrative Inspection · Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3548169
2 April 2009
Excursion Permit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3444808
27 October 2008
Damage Survey · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3352166
23 October 2008
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3419102
22 May 2008
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3213400
18 September 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3062389
22 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2936962
14 May 2007
Simplified Stability Test · Administrative Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2929996
22 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2784743
1 May 2006
Initial Certification · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2635563
20 October 2005
Plan Review "T" Boat · Initial Certification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2518567
22 September 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2498427
2 September 2005
Simplified Stability Test
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2485064
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2024
Resolved
Each nozzle must be corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. The nozzle on board does not change into a spray pattern.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: New nozzle, all sat
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2024
Resolved
At each inspection, bilges are examined to see that there is no excessive accumulation of oil. The engine room bilges has an accumulation of oil and oily pads.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 19 August 2024
Resolution: Operator submitted photos of cleaned e/r bilges
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2024
Resolved
Shutoff valves must be fitted in the fuel supply lines to stop the flow of fuel. There were zip ties on the reach rod of the aft fuel shutoff. Remove zip ties and ensure shutoff valve is still operable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: zip ties were removed and replaced with metal wire
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 July 2024
Resolved
Each lifefloat and buoyant apparatus must have a waterlight approved under 46 CFR 161.010. The water light for one of the lifefloats is not working and both waterlights for the lifefloats are expired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: Waterlight batteries were replaced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 July 2024
Resolved
Each overnight accommodation space on a vessel must be fitted with an independent modular smoke detector. The smoke detector in the overnight accommodation space needs a battery replacement.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: Battery was replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 August 2023
Resolved
crop and renew wasted bilge pipes in tank space. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 3 October 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 August 2023
Resolved
The vessel needs to be dry dock to see the extent of the damage that occurred after grounding. The entire hull, shafts, props, rudder, and struts need to be examine for further damage. Submit a repair proposal to the CG for approval. Make repairs after approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2023
Resolution: Sector NY open their own def. They are conducting Hull/ISE and has issued more items to address.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 July 2023
Resolved
The generator exhaust stbd side laz, has a crack in the weld. Issued requirement to fix crack.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Cracked weld was fixed with a doubler and welded both ends and seem.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 25 May 2022
Resolved
Provide position information for DSC capable radio.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: Radio is providing position information.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 March 2022
Resolved
Crop and renew cracked and holes side shell plating on the stbd quarter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Holes in sideshell repaired and approved by attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 March 2022
Resolved
Crop and renew cracked and holes side shell plating on the stbd quarter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Holes in sideshell repaired and approved by attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 March 2022
Resolved
Renew overboard discharge pipe for sink. Pipe is holes in way of the check valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Overboard discharge pipe repaired and approved by attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 March 2022
Resolved
Make penetrations in E/R blkd gas tight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2022
Resolved 25 May 2022
Resolution: Penetrations in E/R were repaired and approved by attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 March 2022
Resolved
Tighten rear engine mounts for ship service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Rear engine mounts for ship service generator repaired and approved by attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 April 2021
Resolved
The hatch exposed to the weather must be watertight. The E/R and steering space hatches are not watertight. Repair to work as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: installed new gasket and verified watertight integrity.
Installed new gaskets and verified watertight integrity.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 April 2021
Resolved
Lifelines and pendants are tangled between LF. LF should be free of any obstruction in event of emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: All lifelines and pendants are separated and stored to avoid entanglement.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 April 2021
Resolved
The float light on both LF is not wrapped around the body.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Float lights are secured arounf the body of LF.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 April 2021
Resolved
Each LF must have a retro tape. The retro tape is deteriorated and needs renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: LF have new retro tape installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2021
Resolved
Remote Fuel Valves shutoff station must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction or operation. Fuel shutoff valve not marked. Label fuel shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Remote fuel valves are label correctly and with operation direction.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2021
Resolved
Vessel doesnt have required first aid with all contents to meet approval series 160.41. Fit vessel with first aid kit meeting requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Required first aid kit onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2021
Resolved
None of the crew accomdation spaces rack lighting are operable. Repair to function as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Crew accommodation space lighting is in good working order.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 22 April 2021
Resolved
The man overboard recovery device had a seized ratchet crank. Replace and prove proper operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Provided evidence that the equipment does work for recovering MOB.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 October 2019
Resolved
Provide propper operation of E-lights
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: Tested e-lights satisfactorily
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019
Resolved
Replace mattresses with mattresse that comply with current fire rating
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: 8 Mattresses replaced that adhere to 46 CFR 1632 standard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 October 2019
Resolved
Replace smoke alarm located in passenger berthing area
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: replaced with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019
Resolved
Re-crimp possitve terminal cable on starboard engine to the battery.
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 July 2019
Resolved
Properly install electrical light in shower
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2019
Resolved 16 August 2019
Resolution: O/O provided pictures of new fixture.
Communications › Audible Communications › Horn/Whistle
Issued 29 April 2016
Resolved
Repair vessel's horn.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Horn repaired.
Lifesaving › Lifefloat › Markings
Issued 29 April 2016
Resolved
Re-stencil life floats.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Life floats re-stenciled.
Lifesaving › Lifefloat › Paddle
Issued 29 April 2016
Resolved
Stencil lifeflaot paddles with vessel name.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Paddles stenciled.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 April 2016
Resolved
Repair compass light.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Light repaired.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 April 2016
Resolved
Repair emergency light in lower passenger compartment.
Due 29 May 2016
Resolved 1 June 2016
Resolution: Lighting repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2016
Resolved
Renew expired medications in first aid kit.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Meds updated.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 April 2016
Resolved
Remove dead ended cable under pilothouse console.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Cable removed.
Construction/Loadline › Structures › Scuttle
Issued 29 April 2016
Resolved
Renew gaskets on engine room hatches.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Gaskets replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 September 2015
Resolved
Demonstrate proper operation of port MDE. Engine will not start.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2015
Resolution: Vessel's electrical system switched to 24 v. Vessel's MDEs tested satisfactory. [name withheld]
Stability › Watertight Integrity › Coaming
Issued 28 July 2009
Resolved
Provide and install during the dry dock dated 8/15/09 a six inch coaming on the aft weather deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 August 2009
Resolved 18 August 2009
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 May 2008
Resolved
Replace old battery on accommodation space smoke detector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Resolution: Corrected date of exam.
Stability › Intact Righting Energy › General
Issued 13 December 2007
Resolved
Conduct a satisfactory simplified stability test for exposed waters. Until the test is completed and a new stability letter issued this vessel shall not operate beyond partially protected waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 14 May 2008
Resolution: Witnessed a SST & filed a completed CG-4006. New stability ltr developed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 May 2007
Resolved
Repair exhaust leek on Stbd. MDE.
Due 30 May 2007
Resolved 23 May 2007
Resolution: Repaired exhaust leak on stbd MDE.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 22 May 2007
Resolved
Repace worn hose on stbd Jabsco pump
Due 30 May 2007
Resolved 23 May 2007
Resolution: Repaced worn hose on stbd Jabsco pump
Lifesaving › Lifebuoys › Serviceable
Issued 22 May 2007
Resolved
Replace one worn lifering prior to sail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 23 May 2007
Resolution: Replaced worn lifering with new one.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 1 May 2006
Resolved
Provide medium frequency radio. Vsl limited to <20 from shore. Provide new safety radio cert.
Due 19 May 2006
Resolved 28 August 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 1 May 2006
Resolved
Provide flame screens fro all fuel and MSD tank vents.
Due 19 May 2006
Resolved 9 May 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 May 2006
Resolved
Provide dead cover for all distribution boxes.
Due 19 May 2006
Resolved 9 May 2006
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 1 May 2006
Resolved
Provide and post emg. instruction list.
Due 19 May 2006
Resolved 9 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 1 May 2006
Resolved
Remove dead end wire stbd side bulkhead in fuel compartment.
Due 19 May 2006
Resolved 9 May 2006
Lifesaving › Lifefloat › Float-free Link
Issued 1 May 2006
Resolved
Perminately connect LF's with line or provide another weak link for other LF.
Due 19 May 2006
Resolved 9 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 1 May 2006
Resolved
Provide ligths for all life jackets. Vsl limited to <20 miles from shore.
Due 19 May 2006
Resolved 9 May 2006
Deck/Cargo › Mooring/Anchoring › Winch
Issued 1 May 2006
Resolved
Prove proper operation of Windlass.
Due 19 May 2006
Resolved 22 September 2006
Resolution: Per fax ltr fm o/o, ltr scanned into documents for this activity.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 22 September 2005
Resolved
Provide copy of valid FCC Safety Radiotelephony Certificate.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Resolution: Need a new cert including SSB/MF
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 September 2005
Resolved
Install bonding wire from fuel fill to tank.
Condition: Improper Installation
Due 28 October 2005
Resolved 1 May 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 September 2005
Resolved
Seal hole in Lazz forward bulkhead stbd side of fuel fill.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 September 2005
Resolved
Grind/reweld #1 deck long. port forward lazz. as marked.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Construction/Loadline › Hull › Bracket
Issued 22 September 2005
Resolved
Grind/reweld platform supports in lazz port/stbd sides iwo #1 vdwfs and at forward stbd corner.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Engineering › Bilge Water Management System › Hose
Issued 22 September 2005
Resolved
Reapir lazz. bilge suction line (crimped hose).
Condition: Improper Installation
Due 28 October 2005
Resolved 1 May 2006
Engineering › Steering Gear System › Piping
Issued 22 September 2005
Resolved
Repair wasted steering system pipe unions as needed in lazz.
Condition: Improper/Lack of Maintenance
Due 28 October 2005
Resolved 1 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2005
Resolved
Replace globe on light fixture in lazz.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Electrical › Lighting (service) › Conductor
Issued 22 September 2005
Resolved
Remove dead-ended electrcal wiring throughout vessel (lazz, e/r vent trunks, e/r to aft throttle station).
Condition: Improper/Lack of Maintenance
Due 28 October 2005
Resolved 1 May 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 22 September 2005
Resolved
Prove watertightness of engineroom deck hatches.
Condition: Improper/Lack of Maintenance
Due 28 October 2005
Resolved 1 May 2006
Construction/Loadline › Hull › Transverse Frame
Issued 22 September 2005
Resolved
Weld all vdwfs at top to deck in engine room.
Condition: Improper Installation
Due 28 October 2005
Resolved 1 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 September 2005
Resolved
Repair MDE exhaust insulation as needed.
Condition: Improper/Lack of Maintenance
Due 28 October 2005
Resolved 1 May 2006
Engineering › Bilge Water Management System › Not Operational
Issued 22 September 2005
Resolved
Remove oil and clean engineroom bilges.
Condition: Improper/Lack of Maintenance
Due 28 October 2005
Resolved 1 May 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 22 September 2005
Resolved
Seal holes in stbd E/R vent trunk.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 22 September 2005
Resolved
Replace missing connection box cover to hot water heater.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 September 2005
Resolved
Seal holes in mid machinery space aft bulkhead and seal pipe penetrations to E/R.
Condition: Unknown
Due 28 October 2005
Resolved 1 May 2006