JOEL W MILLER is a 1974 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in April 2026, along with 35 deficiencies and 4 casualty investigations between 2008 and 2020.

Records from 2008 to 2026. Most recent: inspection, 15 April 2026.

Built
1974
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB3245
128405
Flag
UNITED STATES
Maury page id
psix-128405

Documentation record

Registered dimensions (L × B × D)60.2 ft × 16.6 ft × 7.8 ft
Registered tonnagegross 52 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT JEFFERSON, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANTARCTICA Tank Ship · MISLE 957025 · 13 October 2020 · activity 7078207

Inspection history · 24

15 April 2026 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8340376
6 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264871
9 May 2025 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8131588
22 July 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7965142
21 August 2023 Internal Structural Exam · Drydock Exam · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7773090
18 August 2023 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7771160
6 July 2023 Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7734986
31 May 2022 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7464080
25 May 2022 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7452005
23 March 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7416644
12 November 2021 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7349594
22 April 2021 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7171265
14 October 2020 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7077977
13 October 2020 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7078207
20 July 2020 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007802
6 January 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7011266
1 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6825657
1 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6769302
23 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6719838
2 July 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6464130
17 January 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339355
12 July 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5944577
25 April 2016 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5862143
6 April 2016 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5848407

Deficiency record · 35

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2024 Resolved
Each nozzle must be corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. The nozzle on board does not change into a spray pattern.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: New nozzle, all sat
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2024 Resolved
At each inspection, bilges are examined to see that there is no excessive accumulation of oil. The engine room bilges has an accumulation of oil and oily pads.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 19 August 2024
Resolution: Operator submitted photos of cleaned e/r bilges
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2024 Resolved
Shutoff valves must be fitted in the fuel supply lines to stop the flow of fuel. There were zip ties on the reach rod of the aft fuel shutoff. Remove zip ties and ensure shutoff valve is still operable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: zip ties were removed and replaced with metal wire
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 July 2024 Resolved
Each lifefloat and buoyant apparatus must have a waterlight approved under 46 CFR 161.010. The water light for one of the lifefloats is not working and both waterlights for the lifefloats are expired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: Waterlight batteries were replaced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 July 2024 Resolved
Each overnight accommodation space on a vessel must be fitted with an independent modular smoke detector. The smoke detector in the overnight accommodation space needs a battery replacement.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 8 August 2024
Resolution: Battery was replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 August 2023 Resolved
crop and renew wasted bilge pipes in tank space. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 3 October 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 August 2023 Resolved
The vessel needs to be dry dock to see the extent of the damage that occurred after grounding. The entire hull, shafts, props, rudder, and struts need to be examine for further damage. Submit a repair proposal to the CG for approval. Make repairs after approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2023
Resolution: Sector NY open their own def. They are conducting Hull/ISE and has issued more items to address.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 July 2023 Resolved
The generator exhaust stbd side laz, has a crack in the weld. Issued requirement to fix crack.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 10 July 2023
Resolution: Cracked weld was fixed with a doubler and welded both ends and seem.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 25 May 2022 Resolved
Provide position information for DSC capable radio.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: Radio is providing position information.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 March 2022 Resolved
Crop and renew cracked and holes side shell plating on the stbd quarter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Holes in sideshell repaired and approved by attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 March 2022 Resolved
Crop and renew cracked and holes side shell plating on the stbd quarter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Holes in sideshell repaired and approved by attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 March 2022 Resolved
Renew overboard discharge pipe for sink. Pipe is holes in way of the check valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Overboard discharge pipe repaired and approved by attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 March 2022 Resolved
Make penetrations in E/R blkd gas tight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2022
Resolved 25 May 2022
Resolution: Penetrations in E/R were repaired and approved by attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 March 2022 Resolved
Tighten rear engine mounts for ship service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: Rear engine mounts for ship service generator repaired and approved by attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 April 2021 Resolved
The hatch exposed to the weather must be watertight. The E/R and steering space hatches are not watertight. Repair to work as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: installed new gasket and verified watertight integrity. Installed new gaskets and verified watertight integrity.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 April 2021 Resolved
Lifelines and pendants are tangled between LF. LF should be free of any obstruction in event of emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: All lifelines and pendants are separated and stored to avoid entanglement.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 April 2021 Resolved
The float light on both LF is not wrapped around the body.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Float lights are secured arounf the body of LF.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 April 2021 Resolved
Each LF must have a retro tape. The retro tape is deteriorated and needs renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: LF have new retro tape installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2021 Resolved
Remote Fuel Valves shutoff station must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction or operation. Fuel shutoff valve not marked. Label fuel shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Remote fuel valves are label correctly and with operation direction.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2021 Resolved
Vessel doesnt have required first aid with all contents to meet approval series 160.41. Fit vessel with first aid kit meeting requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Required first aid kit onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2021 Resolved
None of the crew accomdation spaces rack lighting are operable. Repair to function as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 6 May 2021
Resolution: Crew accommodation space lighting is in good working order.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 22 April 2021 Resolved
The man overboard recovery device had a seized ratchet crank. Replace and prove proper operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Provided evidence that the equipment does work for recovering MOB.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 October 2019 Resolved
Provide propper operation of E-lights
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: Tested e-lights satisfactorily
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019 Resolved
Replace mattresses with mattresse that comply with current fire rating
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: 8 Mattresses replaced that adhere to 46 CFR 1632 standard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 October 2019 Resolved
Replace smoke alarm located in passenger berthing area
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: replaced with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
Re-crimp possitve terminal cable on starboard engine to the battery.
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 July 2019 Resolved
Properly install electrical light in shower
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2019
Resolved 16 August 2019
Resolution: O/O provided pictures of new fixture.
Communications › Audible Communications › Horn/Whistle
Issued 29 April 2016 Resolved
Repair vessel's horn.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Horn repaired.
Lifesaving › Lifefloat › Markings
Issued 29 April 2016 Resolved
Re-stencil life floats.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Life floats re-stenciled.
Lifesaving › Lifefloat › Paddle
Issued 29 April 2016 Resolved
Stencil lifeflaot paddles with vessel name.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Paddles stenciled.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 April 2016 Resolved
Repair compass light.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Light repaired.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 April 2016 Resolved
Repair emergency light in lower passenger compartment.
Due 29 May 2016
Resolved 1 June 2016
Resolution: Lighting repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2016 Resolved
Renew expired medications in first aid kit.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Meds updated.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 April 2016 Resolved
Remove dead ended cable under pilothouse console.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Cable removed.
Construction/Loadline › Structures › Scuttle
Issued 29 April 2016 Resolved
Renew gaskets on engine room hatches.
Due 29 May 2016
Resolved 12 May 2016
Resolution: Gaskets replaced.

Casualty record · 4

23 October 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3419102
8 October 2015Routine · role: Involved in a Marine Casualty · activity 5738694
12 July 2016Routine · role: Involved in a Marine Casualty · activity 5944577
13 October 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7078207
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.