SILVER ESTHER is a 2014 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in August 2026, along with 5 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 5 August 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13632 - Convention (Subpart B), Net Ton 49765 - Dead Weight, Metric Ton 60305 - Displacement, Metric Ton 29460 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
5 August 2026COC-CHEM & TVE Annual · Administrative Inspection
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 March 2021Resolved
The inert gas system shall be capable of inerting, purging, and gas freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. The inert gas generator onboard was inoperable and unable to inert cargo tanks.
SOLAS (14)II-2 5.5.3.1
17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2021
Resolved 19 March 2021
Resolution: Vessel submitted class and service report attesting to the satisfactory repairs of the Inert gas system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 March 2021Resolved
The company and ship shall comply with the requirements of the international safety code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules. In meeting these requirements, the company should ensure that 1) any nonconformity is reported 2)records of these activities are maintained.
PSCO observed an inoperable Inert Gas System. Crew reported that system had been inoperable since 13Mar21, however, PSCO observed objective evidences that system had been inoperable as early as 11Mar21. No formal report was made to the company. In addition, PSCO observed maintence log for EEBD's in engine room prefilled or missing indicating that the records were falsified. An internal ISM audits is required of the vessel's reporting and record keeping procedures to be completed within 3 months of this report.
SOLAS (14) IX-3.1
705ac
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 June 2021
Resolved 4 August 2025
Resolution: Deficiency cleared by PSC team
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 29 January 2020Resolved
06105- In addition to the requirements in paragraphs 5.7.1 and 5.7.2, oil tankers of 20,000 tonnes deadweight and above, constructed on or after 01 January 2012, shall be provided with a fixed hydrocarbon gas detection system complying with the Fire Systems Code. PSCO observed multiple sampling ports displaying a flow fault. Complete needed repairs prior to loading cargos requiring a gas detection system. SOLAS 74(a)2014(cons) II-2/4.5.7.3.1 A
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 February 2020
Resolution: PSC NOLA RECIEVED A CLASS REPORT FROM LR SATISFYING THE REQUIREMENT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2020Resolved
99901- A vessel owner or operator required by 155.1035, 155.1040 or 155.5035 to have a response plan shall conduct exercise as necessary to ensure that the plan will function in an emergency. Qualified Individual notification exercises which must be conducted quarterly. Ship did not conduct QI notificaion exercise. 33 CFR 155.1060(a)(1) 10C
Action required: 10 - Deficiency Rectified
Resolved 29 January 2020
Resolution: Master conducted a QI notification excersise.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 18 May 2016Resolved
2510: Vessel must maintain a Ballast Water Management and Bio-Fouling plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow. The vessel currently does not follow the Ballast Water Mangement Plan and the Bio-Fouling Management Plan is incomplete and does not meet requirement under 33CFR2050(g), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Spoke with the Captain, Chief Mate and Chief Engineer about what was needed
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.