LEROY A. MENDONCA

LEROY A. MENDONCA is a 2001 freight ship. The Coast Guard has recorded 57 inspections since 2016, most recently in March 2026, along with 81 deficiencies, 3 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2023 and 2024.

Records from 2016 to 2026. Most recent: inspection, 10 March 2026.

Built
2001
Last inspected
10 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 March 2026
…with no type recorded10
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9147320
Flag
UNITED STATES
Maury page id
psix-1285

Documentation record

Registered dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
Registered tonnagegross 69,365 / net 20,809
ITC dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
ITC tonnagegross 69,365 / net 20,809
BuilderNORTHROP GRUMMAN SHIP SYSTEMS · AVONDALE, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20809 - Convention (Subpart B), Net Ton
69365 - Convention (Subpart B), Gross Ton
33681 - Dead Weight, Ton
62833 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

57 inspections, each with its date, unit and type; 81 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 57

10 March 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8323720
8 October 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8249289
28 May 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8139834
9 May 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8131770
13 August 2024 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7976132
1 August 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7972530
4 April 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7895276
1 April 2024 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7888053
14 March 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7878872
12 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7864527
12 February 2024 ACP Additional Oversight – Risk Assessment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7864582
5 February 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7863617
16 August 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7770771
16 March 2023 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7652182
16 February 2023 Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 7638115
15 February 2023 Type not recorded
No type recorded · Activities Europe · Activity 7650569
20 December 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7611763
30 November 2022 Deficiency Check · MTSA/ISPS Verification · ISM Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7600558
27 July 2022 Type not recorded
No type recorded · Activities Europe · Activity 7521873
4 July 2022 Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7496664
13 June 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7480492
20 March 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7595359
8 March 2022 Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7407991
11 August 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7283715
22 June 2021 Annual Inspection · ACP COI Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7222295
10 March 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7154108
22 February 2021 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7144213
7 August 2020 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7028841
17 July 2020 Permit to Proceed · ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7008789
19 May 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6953432
27 January 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6896853
15 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6860264
31 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6846559
28 October 2019 ACP Additional Oversight – Risk Assessment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6837507
23 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6843443
20 September 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6816912
19 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6816065
13 September 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6811397
10 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6709583
10 April 2019 Annual Inspection · ACP Annual Oversight · ACP Periodic Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6659214
4 December 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6592099
29 November 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6589800
29 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6570056
20 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6564896
15 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6561314
26 February 2018 ACP Annual Oversight · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6349731
13 January 2018 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7505814
6 January 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6334363
12 December 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6323951
22 November 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6311385
2 September 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6259786
5 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6183274
17 February 2017 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6091656
10 January 2017 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6068355
12 April 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6040509
11 April 2016 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5853441
22 February 2016 ACP COI Oversight
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5819612

Deficiency record · 81

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in these divisions. Cargo deck ventilation damper 6-48-1 in way of fan SS-123 does not fully close. 74 SOLAS(20) II-2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 June 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Door 3-72-0 on B deck leading into SOPEP locker was damaged and unable to close. 74 SOLAS(20) I-I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 28 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI observed significant water leak from overhead aft stbd corner of helo deck hatch leaking into B deck. 74 SOLAS(20) I-I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fixed low-pressure CO2 Tank Shut Off Valve was observed in the closed position restricting activation of system. 74 SOLAS(20) II-2/ 14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 28 May 2025
Resolution: Chief Mate opened the valve
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2025 Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Life ring on stbd side near Fire Station 11-4 had a fully disintegrated plug exposing inside foam. 74 SOLAS (20) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 28 May 2025
Resolution: Chief Mate replaced the lifering
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The 480 VAC BUS ground detection was showing a ground on the “C” phase on the emergency switchboard. 74 SOLAS(20) I-I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 28 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2025 Resolved
Electrical installations shall be such that the safety of the crew and the ship from electrical hazards will be ensured. A fan was wired into the spare breaker (9-406 EP) in the distribution panel near the emergency switchboard in the EDG space. The front of the distribution panel was removed and hanging from two screws to all the cable to be sandwiched between the door and the back of the panel. 74 SOLAS(20) II-I/ 40.1.3
Action required: 10 - Deficiency Rectified
Resolved 28 May 2025
01 - Certificates & Documentation › 013 - Documents › STS Operation Plan and Records of STS Operations
Issued 28 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Records for dates of completion of the ABS approved Periodic Safety Test Procedures were incomplete. 74 SOLAS(20) I-I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 May 2025 Resolved
No vessel subject to inspection and certification shall be operated without a valid certificate of inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for COI annual inspection. 36 CFR 91.01-2 46 CFR 91.27-1 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 August 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Fire vent damper 02-101-3 in the EDG space is stuck in the open position. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 August 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The EDG space fixed CO2 fire-fighting branch line piping is broken at the pipe to discharge nozzle horn connection. 74SOLAS (20) II-2/14.2.1.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 August 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Found the following three engine room supply vent dampers will not fully close: 2-85-2/SS138, 2-89-1/SS136, 2-88-1/SS135. Found engine room supply vent damper 2-89-2/SS140 is not connected to its associated motor, and vessel was unable to demonstrate damper operation. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 13 August 2024 Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulations II-1/42 or II-1/43, as appropriate. Embarkation lighting for aft liferafts found inoperable. 74SOLAS(97) III/15.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 August 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Found overhead access panel for the remote operator ventilation fire damper 1-98-2, AC-05 will not fully open due to being blocked by a refrigeration unit, rendering the remote operator inaccessible. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 20 August 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found lifted wire leads behind Main Control Console panels #1 and #3. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 20 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions to the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. When witnessing the engine order telegraph (EOT) test, MI observed the STBD indicator was not moving as designed. 74SOLAS(97)I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2024
Resolved 20 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Emergency equipment for 2-way comm.
Issued 13 August 2024 Resolved
At least three two-way VHF radiotelephone apparatus shall be provided on every cargo ship of 500 gross tons and upwards. Such apparatus shall conform to performance standards not inferior to those adopted by the Organization. Vessel had two out of the three emergency two-way VHF radios on the bridge did not have the tamper proof seal. 74SOLAS(97) III/6.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2024
Resolved 20 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 August 2024 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Port and STBD bridge wing lifebuoy with attached smoke was not in compliance with manufacturer's instructions. The line attaching the smoke float to the body of the lifebuoy was not at proper length requirement. 74SOLAS(20) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 13 August 2024
Resolution: Vessel spliced line with proper length and attached smoke float to body of lifebouy.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 August 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions to the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While witnessing the watertight doors test, MI observed the visual indicator for 5-99-2 not responding correcting to the movement of the door.
Action required: 10 - Deficiency Rectified
Resolved 13 August 2024
Resolution: Vessel was able to fix error with watertight door panel and retest doors satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 1 August 2024 Resolved
Vessel must undergo an annual inspection within the 3 months before or 3 months after each anniversary date. Vessel did not complete an annual exam within the window of inspection based on the COI anniversary date 31 Jan. 46 CFR 91.27-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 August 2024
Resolution: Conducted CG ACP Annual
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 April 2024 Resolved
The safety-management system shall be maintained in accordance with the provisions of the International Safety Management Code. 10.1 - The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. 10.2 In meeting these requirements the Company should ensure that: .1 inspections are held at appropriate intervals; .2 any non-conformity is reported with its possible cause, if known; .3 appropriate corrective action is taken Objective evidence shows that engine hours were not transfered to the NSE maintenance system, and hour based maintenance is not being properly tracked. No non-conformity was reported per the code. Company is to conduct an investigation to determine the root cause, develop and implement any corrective action into the SMS to prevent future occurrences. Require additional SMC verification be conducted focusing on maintenance tracking and promulgation.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2024
Resolved 13 August 2024
Resolution: ABS conducted SMC verification focusing on the maintenence tracking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 August 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The #3 lifeboat door is cracked and the engine was unable to be started. 74 SOLAS (20) III/20.2, 17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 August 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The #1 lifeboat was missing motor mount, fuse box cover, and engine cover. 74 SOLAS (20) III/20.2, 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 August 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. No liferafts were present onboard the vessel. 74 SOLAS (20) III/20.2, 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .1 structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Whether actuated remotely and/or manually, many randomly tested fire dampers on the cargo deck failed to close fully. 74 SOLAS (97) II-2/44.1, 701a
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .1 structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Of the ventilation shafts that were available for inspection on the lowest deck, many of the ventilation shafts (including the shafts associated with fire dampers 7-75-2 and 7-80-2) were wasted through with holes visible. 74 SOLAS (97) II-2/44.1, 701a
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 August 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The required running lights on the rescue boat were inoperable. 74 SOLAS (20) III/20.2, 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2023
Resolved 24 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations to ensure that the ship in all respect will remain safe to proceed to sea without danger to the ship or persons onboard. Exhaust lagging on all four SSDGs IWO turbos was falling off exhaust piping and covered with exhaust soot. 74 SOLAS (20) I/11(a), 17a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2023
Resolved 24 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .1 structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. The following fire doors failed to self-close as designed: 01-97-3, 02-97-3, 02-91-8, 03-97-7, and 03-87-9. 74 SOLAS (20) II-2/14.2.1.1.1, 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2023
Resolved 24 August 2023
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with provision of the present regulations to ensure that the ship in all respect will remain safe to proceed to sea without danger to the ship or persons onboard. Excessive scale and steel wastage was discovered on the deck IWO fire damper 2-21-1. 74 SOLAS (20) I/11(a), 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2023
Resolved 24 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .1 structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Bulkhead penetrations in the following spaces are not arranged so as to ensure required minimum fire division integrity: fan room IWO 03-97-1, gyro room IWO 03-89-0, fan room IWO 04-85-1, electrical equipment room IWO 03-8-6, and the space located directly under the pilothouse. 74 SOLAS (97) II-2/44.1, 50a
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2023
Resolved 24 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .1 structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. The rolling shutter door that constituted the fire boundary between the galley and the surrounding spaces failed to close fully. Corrected on the spot. 74 SOLAS (97) II-2/44.1, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 August 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 August 2023 Resolved
Fire-fighting appliances shall be kept in good working order and readily available for immediate use. Portable fire extinguishers stowed in lifeboats were not properly mounted and/or tied off with line, rendering them unready for immediate use. Corrected on the spot. 74 SOLAS (20) II-2/14.2.1.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 16 August 2023
Resolution: Corrected on the spot
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Pinhole leak discovered on inlet water piping between skin valve and sea chest at welded junction from 22" pipe from sea chest to 5" pipe to saltwater evap #1. Temp repairs made to reduce water ingress. Vessel shall immediately return to Rota, Spain at safe speed to complete permanent repairs prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2023
Resolution: Temp welding repairs completed/approved by ABS. Condition to stay open until pipe section is replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 July 2022 Resolved
Each watertight subdivision bulkhead, whether transverse or longitudinal shall be constructed in such a manner that it shall be capable of supporting with proper margin of resistance, the pressure due to max head of water which it might have to sustain in the event of damage to the ship. While loading the port side vehicle access door at 5-71-2 was struck and damaged. Repairs shall be approved and tested by the attending marine surveyor from (RO) American Bureau of Shipping. 74 Solas (04) II-1/14
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 July 2022
Resolution: Vessel provided ABS class report attesting to the satisfactory repair and testing of the damaged watertight door.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 4 July 2022 Resolved
All ships of 500GT shall have a gyro compass heading or other means to determine and display their heading by shipborne non magnetic means. The gyro repeater at the helm is not working. Make repairs to system by replacing fried card for helm gyro repeater. All other gyro repeaters are working. Repairs made to the satisfaction of ABS. 74 Solas (20) V/19.2.5.1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2022
Resolution: Vessel provided ABS class report attesting to the satisfactory repair and testing the affected gyro repeater.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 March 2022 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs, this includes the fire detection and fire alarm systems. Vessel’s fire detection panel is showing 5 faults in the cargo holds, that the vessel is unable to clear.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 25 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel’s sliding watertight door #571-1 located on the D4 cargo deck will not lock in place. Crew is able to manually manipulate the solenoid to close and lock the watertight door. Vessel is to keep door closed and locked while underway until repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 March 2022 Resolved
Machinery spaces of category A containing internal combustion machinery shall be provided with one of the fire-extinguishing systems required by paragraph 1.1. (Paragraph 1.1.1) a gas system complying with the provisions of regulation 5. (Regulation 5.1.4) Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. Emergency Generator room contains an opening in overhead allowing for engine exhaust pipping exit with no means of closure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping, systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being to paid to moving parts, hot surfaces, and other hazards. Auxiliary boilers safety valve handles have springs wrapped around them preventing proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to see without danger to the ship or persons onboard. Multiple hydraulic leaks and deteriorated hoses in steering gear room on the steering system and hydraulic power unit (HPU) system for stern ramp door and below normal hydraulic level in both HPUs with active low hydraulic level alarm on panel for the stern ramp door system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 June 2021 Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. The fixed CO2 system for the EDG compartment had a broken distribution line. 74SOLAS(20)II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship is fit to proceed to sea without danger to the ship or persons on board. The workshop water tight door was not able to be opened locally using the manual pump/control. 74SOLAS(20)I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 22 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure the ship is fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. Ship’s crew was not able to operate and test the OWS in the presence of CG Marine Inspector. MARPOL(17)Annex I/6.4.1
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 June 2021 Resolved
After survey of the ship, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Steering flat had a space heater hard wired into a motor controller for a capstan. 74SOLAS(20)I/11(b)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 June 2021 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in the divisions shall be kept in good order so as to ensure their required performance if a fire occurs. There were 20 holes discovered in the B-0 forward bulkhead and overhead between the navigation bridge and the radio room and chart room. 74SOLAS(20)II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 June 2021 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in the divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Fire dampers 4-27-1 (C1), 3-50-3 (B3), and 3-57-1 (B3) did not close properly and need to be adjusted. Vessel may not carry cargo in spaces C1 and B3 prior to adjustment. 74SOLAS(20)II-2/14.2.1.1.1
Action required: 705 - Other - as specified
Resolved 6 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 June 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Both lines attaching the bridge wing smoke floats to the ring buoys were too short. 74SOLAS(20)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 22 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the regulations to ensure the ship will remain fit to proceed to sea. The green "closed" light on the bridge watertight door panel for DR. NO. 5-99-2 was extinguished. 74SOLAS(20)I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 22 June 2021 Resolved
Simple operating instructions with a block diagram showing the change-over procedures for remote steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge and in the steering compartment. The steering compartment was missing operating instructions. 74SOLAS(20)V/26.3.1
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 22 June 2021 Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. Conduct fire and abandon ship drills, to include lowering a lifeboat, in the presence of the attending Coast Guard Marine Inspector prior to activation. 74SOLAS(20)III/19.3.1
Action required: 705 - Other - as specified
Resolved 11 August 2021
Resolution: Witnessed launching and maneuvering of the No. 2 lifeboat. Witnessed satisfactory fire and abandon ship drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 22 June 2021 Resolved
Upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed in accordance with the COI manning to the satisfaction of the attending Coast Guard Marine Inspector. 46CFR15.401
Action required: 705 - Other - as specified
Resolved 11 August 2021
Resolution: Inspected all MMCs and verified minimum safe manning.
11 - Life Saving Appliances › N/A - No Subsystem › Thermal Protective Aids
Issued 22 June 2021 Resolved
Lifesaving appliances and arrangements required by this chapter, shall be approved by the Administration. Lifeboat thermal protective aids are not CG approved. 74SOLAS(97)III/4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 March 2021 Resolved
Cargo ships of 1,000 GT and upwards shall be provided with at least 2 independently driven fire pumps. Vessels #2 Fire Pump is inoperable. 74SOLAS (97) II-2/4.3.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2021
Resolved 17 May 2021
Resolution: Received letter from class clearing def.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 July 2020 Resolved
During an On-board Condition Inspection Enhanced and Dock Trial (OCI-E, DT) 02-06 March 2020. It was discovered a) That the ship did not have adequate LP CO2 fire suppression agent b) The cargo WTD 4-71-1 [cargo hold C4] and WTD 7-71-2 [cargo hold F3] failed to latch. -- As per the ship's Safety Management System these items CO2 Plant and Watertight Doors are considered Critical Equipment (ISM Code 10) -- Whenever an a defect is discovered which affects the safety of the ship the master or owner of the ship shall report at the earliest opportunity to the recognized organization responsible for issuing the relevant certificate. Provide Proof that the Authorized Classification Society was notified of these major findings
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2020
Resolved 28 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 May 2020 Resolved
Lifeboat ladders attachment points were severly wasted, gauge to sat of Class or replace to same.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2020
Resolved 28 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 May 2020 Resolved
Recue boat did not start and the battery needed to be charged before it would even turn over.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 May 2020
Resolution: started once charged
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2019 Resolved
Vessel self-reported degraded AIS on board vessel. AIS must be maintained in effective operating condition. Repair AIS to the satisfaction of class prior to departure. (74 SOLAS (2014) V/19.2.2.4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2019
Resolution: Cleared per ABS Report # NN3646088
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 10 June 2019 Resolved
74 SOLAS (14) V/20.2 To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be a S-VDR in the case of cargo ships 20,000 GT and upwards constructed before 1 July 2002. Vessel reported S-VDR circuit board is faulty and requires replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2019
Resolution: Received notification from ABS. ABS Report # NN3661443
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2019 Resolved
Main steering gear and rudder stock shall be capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. The steering gear will not achieve 35 degrees using bridge controls. SOLAS (97) II-1/29.3.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 22 April 2019
Resolution: ABS Report # NN3661443
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 April 2019 Resolved
Structural fire protection penetrations shall be kept in good order to ensure the required performance if a fire occurs. DC Wifcom system penetrates A-60 boundaries in superstructure and cargo stairtowers using non-approved penetration systems. Repair in the presence of ABS Surveyor. SOLAS (14) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 28 May 2019
Resolution: ABS Report # NN3661443
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 April 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Embarkation lighting swing arms are severely wasted. Crop and renew to the satisfaction of Class. SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 10 May 2019
Resolution: ABS Report # NN3661443
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 April 2019 Resolved
Posters or signs shall be provided on or in the vicinity of the survival craft. Liferaft launching instructions at the main liferaft stations are not visible from the launching station. SOLAS (14) III/9.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 22 April 2019
Resolution: ABS Report # NN3661443
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 10 April 2019 Resolved
A person may not employ or engage an individual and an individual may not serve in a position in which an individual is required by law or regulations to hold license,MMC and TWIC unless the individual holds all credentials required. Upon activation from ROS status, provide crew's credentials to attending CG Marine Inspector
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Crew documents inspected during ROS Activiation to the satisfaction of the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 April 2019 Resolved
Vessel does not maintain up-to-date charts and pubs while in ROS status. Provide up-to-date charts and pubs upon activation to the attending CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Charts and pubs provided during ROS Activation to the satisfaction of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 April 2019 Resolved
Every crewmember shall participate in at least one abandon ship drill and one fire derill every month. When new crew is engaged, drills shall be held before sailing. Upon activation, conduct drills in the prescence of the attending CG marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Crew conducted fire drill and abandon ship muster to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 April 2019 Resolved
Each lifeboat shall be launched and maneuvered in the water by its assigned operating crew at least once every three months. Provide log showing that all boats have been launched as required or launch all lifeboats upon activation in the presences of the attending CG Marine Inspector
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2019
Resolution: Vessel successfully launched, maneuvered, and recovered LB #2 during the previoous annual. Deficiency was issued in error.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 November 2018 Resolved
74SOLAS 81 Amend II-I/44 Each emergency generating set arranged to be automatically started shall be equipped with starting devices appreved by the administration with a stored energy capability of at least three consecutive starts. Vessel start air is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 4 December 2018
Resolution: Recieved report class attended and cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 20 October 2018 Resolved
Vessel is unable to access 02 fuel tanks due to faulty motorized valves. Vessel shall repair and demonstrate satisfactory operation to the satisfaction of the attending ABS Surveyor prior to departure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2018
Resolved 7 November 2018
Resolution: Administratively cleared base on ABS Safenet Report No. NN3558980
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 28 February 2018 Resolved
Enclosed spaces that are specially suitable for vehicles must be fitted with a fire detection and alarm system. Fire detection system has (9) faults.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2018
Resolution: Cleared by ABS
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 February 2018 Resolved
Each watertight door in a required subdivision bulkhead must have an indicator light installed in the pilothouse and each other vessel operating station from which the door is not visible. Several watertight door indicating lights installed in the pilothouse are not functioning to show whether the doors are opened and closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2018
Resolution: Cleared by COrpus Christi Inspections
Documentation › Logs/Records › Logbook (official)
Issued 28 February 2018 Resolved
When fire drills are held, official logbook entries must include identification of crewmembers participating in drills. Vessel crew failed to identify crewmembers participating in fire drills in the official logbook.
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 20 March 2018
Construction/Loadline › Structures › Door
Issued 28 February 2018 Resolved
The integrity of a stairtower shall be maintained by "A" class doors at every level. The doors shall be of self closing type. There are 17 doors not closing properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2018
Resolution: Cleared by ABS
Operations/Management › Drills/Instruction › Fire
Issued 26 February 2018 Resolved
Drills must as far as practicable, be conducted as if there were an actual emergency. Vessels crew failed to adequately demonstrate proficiency in the use of fire fighting equipment and recognition or initial actions necessary, while conducting 2 fire drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2018
Resolution: Cleared by Corpus Christi Inspections
Engineering › Bilge Water Management System › Pump
Issued 12 January 2017 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery or equipment shall be made without the knowledge of OCMI. As per 46CFR56.50-55a, 2 power driven pumps are required. Currently installed diaphragm pump does not meet standards as a bilge pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 16 May 2017
Resolution: Original pump re-installed to the satisfaction of the attending ABS principal surveyor.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 12 January 2017 Resolved
Each lifeboat must be launched with its assigned operating crew aboard and maneuvered in water once every 3 months.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 20 January 2017
Resolution: Received notification/pictures of lifeboats being lowered into water and operationally tested.
Construction/Loadline › Structures › Scuttle
Issued 10 March 2016 Resolved
Replace or Repair scuttle between D and E deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 6 April 2016
Resolution: Replaced scuttle
Stability › Watertight Integrity › General
Issued 10 March 2016 Resolved
Audible and Visual alarms on Watertight door panel inoperable on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 6 April 2016
Resolution: Proved proper operation of audible and visual alarms
Fire Fighting › Fire Hoses › Condition
Issued 10 March 2016 Resolved
Replace 3 50' fire hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 6 April 2016
Resolution: Replaced 3 50' fire hoses.
Fire Fighting › Fire Main › Pressure
Issued 10 March 2016 Resolved
Verify fire main design pressure and verify system componets.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 6 April 2016
Resolution: Verified system design and pressure to satisfaction of attending classification society surveyor.
Operations/Management › Drills/Instruction › Fire
Issued 10 March 2016 Resolved
Conduct firefighting and abandonship drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2017
Resolved 11 April 2016
Resolution: Drills Completed.

Casualty record · 2

15 February 2023Routine · role: Involved in a Marine Casualty · activity 7650569
4 April 2024Routine · role: Involved in a Marine Casualty · activity 7895276
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.