Records from 2014 to 2026. Most recent: inspection, 10 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
10 June 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8397368
16 September 2025
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8237372
10 November 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8042269
27 March 2024
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7885993
31 January 2024
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7858720
3 September 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7643394
9 November 2021
COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7351054
29 June 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7258151
24 November 2020
ISPS Exam · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7102042
24 October 2019
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6839943
3 April 2018
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6427880
11 July 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6249296
5 July 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6218919
18 April 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6127165
5 January 2017
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6065030
15 May 2014
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4859623
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 24 October 2019
Resolved
The Oil Record Book, Whether as a part of the ship's official log-book or otherwise, shall be i the from specified in appendix III to Annex I of MARPOL. The ORB has multiple unclear entires what do not add up properly in order to track oil tranfers and levels in 3.1 sludge tanks. Entries must be made IAW ORB entry instructions listed in the front of the book.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 November 2019
Resolution: DNV/GL taking for action as a condition of class. Follow up with Ed Rivenback.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 24 October 2019
Resolved
Load lines should be assiged to surface units as calculated under the terms of the 1988 LL Protocol and should be subject to all the conditions of assignment of that Protocol. Loadline cannot be seen from helicopter and is not in contrasting color
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 22 November 2019
Resolution: DNV follow up documentation satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 24 October 2019
Resolved
All Lifeboats should be fire-protected in accordance with the LSA Code. Lifeboat airbottles are not pressurized in accordance with OEM recommendations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 22 November 2019
Resolution: Letter by Master.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019
Resolved
The Operator of each manned OCS facility shall develop an emergency evacuation plan for the facility which addresses all of the tiems listed 33 CFR 146.140. EEP was submitted only two days before COC Exam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 7 November 2019
Resolution: Letter from Meagan Reg Spec w/approval letter.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Recruitment and placement service
Issued 24 October 2019
Resolved
Each employee must empoloy U.S. citizens as regular compliment of crew. 31 foreign workers are scheduled to stay in excess of 21 days at the time of the COC issuance. Reconcile with OCMI prior to drilling.
Action required: 66 - Prior to drilling or production operations
Resolved 29 October 2019
Resolution: Statement from Master and Attorney about removal of personnel complete.
Lifesaving › Lifeboat Equipment › Painter
Issued 15 May 2014
Resolved
Consideration should be given to the location and orientation of the survival craft with reference to MODU design such that clearance of the unit is achieved in an efficient and safe manner. Lifeboat gripes getting stuck on davit arms while launching. Replace gripes with originally designed gripes. Remove peg modification on davit arms to originally intended design.
Due 14 July 2014
Resolved 22 June 2014
Engineering › Fuel Oil Service System › Filter
Issued 15 May 2014
Resolved
All machinery and piping systems should be of a design and construction adequate for the intended purpose. Leaking fuel/oil strainer valve in STBD purifier room. Repair/replace to original condition.
Due 28 June 2014
Resolved 16 June 2014
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 15 May 2014
Resolved
Fire safety systems should be in accordance with the fire safety systems code. Multiple faults discovered on fire/gas control panel. Determine source of faults and correct.
Due 21 June 2014
Resolved 11 July 2014
Resolution: Fire Control panel has been properly serviced and is working properly
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 15 May 2014
Resolved
The area of water into which survival craft are to be launched should be adequately illuminated by emergency lighting. Multiple launch lights throughout vessel were not illuminated. Replace/repair to original condition.
Due 28 June 2014
Resolved 11 July 2014
Resolution: All lightbulbs have been installed properly.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 15 May 2014
Resolved
Eyewash equipment providing emergency relief must be immediately available near where eye injury may occur eyewash stations need to be installed in the following locations: mud pump room & mud pit room.
Due 28 June 2014
Resolved 22 June 2014