MAURY USCG vessel records
← All vessels

KOOL CRYSTAL

KOOL CRYSTAL is a 2014 tank ship. The Coast Guard has recorded 19 inspections since 2017, most recently in October 2025, along with 4 deficiencies and 6 operational controls.

Records from 2017 to 2025. Most recent: inspection, 30 October 2025.

Built
2014
Last inspected
30 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 October 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9624926
1286028
Flag
MARSHALL ISLANDS
Maury page id
psix-1286028

Documentation record

Tonnage as PSIX records it102100 - Convention (Subpart B), Gross Ton
82058 - Dead Weight, Ton
30631 - Convention (Subpart B), Net Ton
102100 - Regulatory (Subpart C or D), Gross Ton
30631 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

30 October 2025 PSC B · Administrative Inspection · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8253598
11 December 2024 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8046385
26 October 2024 COC-GAS Annual · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8020660
30 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7831954
15 October 2023 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7804916
26 August 2022 PSC B · COC-GAS Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7543938
21 December 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7368025
9 August 2021 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7277345
28 September 2020 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7062882
27 September 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7066074
25 February 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6910953
16 December 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6873289
13 December 2019 COE-Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6873619
23 July 2019 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6755545
23 July 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6760353
19 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6340250
16 June 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6177864
15 June 2017 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6169439
15 June 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6175052

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 October 2024 Resolved
Except as provided in paragraph 4.2.2, two means of escape shall be provided from each machinery space of category A. PSCO observed non-functioning engine room emergency escape hatch. Compressor room and motor room emergency escape hatches were found with improper installation of security seals which inhibited proper opening. 74SOLAS(20)II-2/13.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2024
Resolved 26 October 2024
Resolution: Deficiency rectified; corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2024 Resolved
Where electrical equipment is installed in gas dangerous spaces or zones as provided in 10.1.4, it should be to the satisfaction of the administration and approved by the relevant authorities recognized by the Administration for operation in the flammable atmosphere concerned. Electrical control panel for LNG vaporizer and Heater #2 in compressor room were found with improperly sealed penetrations. IGC(93)10.1.5 74SOLAS(20)VII/11
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 October 2024
Resolved 11 December 2024
Resolution: Received satisfactory documentation.
Deck/Cargo › Cargo Condition › Other Cargo Type
Issued 15 June 2017 Resolved
Individual master gas valves that close upon leakage of gas, loss of ventilation for the duct or casing or loss of pressurization of the double-wall gas fuel piping are located on the stern and not in the cargo area.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 19 January 2018
Resolution: Received a valid International Certificate of Fitness with an equivalency issued IAW Section 1.4 of the 1993 IGC Code attesting to an equivalent level of safety regarding the Master Gas valves and the requirements of Section 16.3.7 and 16.3.8 of the code.
Deck/Cargo › Cargo Condition › Other Cargo Type
Issued 15 June 2017 Resolved
Gas detection suction sampling system is inoperable and unable to sample and analyse each sampling head location sequentially at intervals not exceeding 30 minutes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Resolution: Received class report attesting to the proper operation of the gas detection suction sampling system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.