NELSON V. BRITTIN

NELSON V. BRITTIN is a 2002 public vessel, unclassified. The Coast Guard has recorded 32 inspections since 2016, most recently in October 2025, along with 36 deficiencies and 1 casualty investigation in 2025.

Records from 2016 to 2025. Most recent: inspection, 22 October 2025.

Built
2002
Last inspected
22 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 October 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9193575
Flag
UNITED STATES
Maury page id
psix-1287

Documentation record

Registered dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
Registered tonnagegross 69,365 / net 20,809
ITC dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
ITC tonnagegross 69,365 / net 20,809
BuilderAVONDALE SHIPYARD · Avondale, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20809 - Convention (Subpart B), Net Ton
69365 - Convention (Subpart B), Gross Ton
29151 - Dead Weight, Ton
58255 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

32 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

22 October 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8255917
29 August 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8220800
27 August 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8219140
27 August 2025 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8219839
12 March 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8092410
25 September 2024 Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8010731
10 March 2023 Deficiency Check · In-Service Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7667291
10 August 2022 Administrative Inspection · ACP Drydock Oversight · ACP COI Oversight · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7530587
25 May 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7459338
7 September 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7305924
6 November 2020 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7090758
9 January 2020 Deficiency Check · ACP Additional Oversight – Risk Assessment · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6881759
15 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6834728
14 July 2019 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6747443
4 July 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6753618
24 December 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6603559
8 November 2018 Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6572164
16 October 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6562901
15 October 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6561233
10 October 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6558983
28 September 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6550526
14 September 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6540730
12 September 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6550854
7 March 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6367849
21 December 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6327547
30 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6315407
24 November 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6312196
8 November 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6304950
6 September 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6261126
31 July 2017 Re-Inspection · Administrative Inspection · ACP COI Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6226561
12 May 2017 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6148676
24 February 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821214

Deficiency record · 36

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 March 2023 Resolved
Unless expressly provided otherwise or unless, in the opinion of the Administration having regard for particular voyages on which the ship is constantly engaged, other requirements are appropriate, all life-saving appliances prescribed in this part shall: be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. Life boats were found to have faded retro-reflective material on the top side of all boats. Replace to satisfaction of ABS. 74 SOLAS (97) III/34; LSA 2/1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 18 September 2023
Resolution: Received ABS report
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 March 2023 Resolved
A fireman's outfit shall consist of: personal equipment comprising: An axe to the satisfaction of the administration. During fire drill, firefighters were not issued fire axes. One axe was presented that was not an insulated fire axe. Provide approved fire axes, such as those required by FSS 3/2.1.1.1.5, or equivalent for each fireman's outfit to the satisfaction of ABS. 74 SOLAS (97) II-2/17.1.1.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 18 September 2023
Resolution: Received ABS report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2023 Resolved
"Trouble" alarm became active during operational testing of the fire detection system and this alarm could not be cleared prior to completion of the COI Exam.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 10 February 2023
Resolution: Deficiency absorbed by ABS, finding number entered above.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 10 February 2023 Resolved
Every oil tanker of 150 gross tonnage and above and every ship of 400 gross tonnage and above other thanan oil tanker shall be provided with an oil record book part 1 (machinery space operations). MI noted in past Oil Record Book a letter from the company stating a 3rd Engineer eronously entered multiple entries into Oil Record Book that did not align with tank ullages or quantities transferred between tanks.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 February 2023
Resolution: ABS issued PR-17 and is initiating further investigation of onboard procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2022 Resolved
Vessel experienced loss of propulsion due to a cracked turbocharger on one MDE and inability to clutch-in on another MDE. A vessel enrolled in the ACP program must comply with applicable class rules for the proper operational status of propulsion machinery. VSL shall not proceed beyond the boundary line until reapirs on the 02 inoperable MDEs are effected to the satisfaction of class and a preliminary report is provided to the CG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2022
Resolved 27 May 2022
Resolution: ABS surveyor attended vessel and verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 7 September 2021 Resolved
Every lifeboat shall have food ration as described in paragraph 4.1.5.1.18 totalling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging. Inspectors found several rations to have lost their airtight packaging. Vessel to ensure each person the lifeboat is permitted has 10,000 kJ. 74SOLAS(09/14)111/34 LSA Ch. IV 4.4.8
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 28 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021 Resolved
The machinery, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended. A hose on the OWS is leaking. Replace hose IAW manufacture specifications. 78 SOLAS 04 Ch. II-1 Reg. 26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No. 1257.0
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2021 Resolved
Fire detection and alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The fire alarm panel in the engine control room is showing a trouble alarm. Correct the fault that is causing the trouble alarm. 78 SOLAS 04 CH. II-1 Reg 14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No 1258
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021 Resolved
In cargo ships, ventilation fans shall normally be run continuously whenever vehicles are on board. Where this is impracticable, they shall be operated for a limited period daily as weather permits and in any case for a reasonable period prior to discharge, after which period the ro-ro or vehicle space shall be proved gas-free. One or more portable combustible gas detecting instruments shall be carried for this purpose. The combustible gas detector in Hold #5 has a sensor fault. Repair fault to ensure proper system operation. 78 SOLAS 04 CH. II-1 Reg 20.3.1.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No 1259.0
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The refrigerant detector is showing a trouble alarm. Correct the fault that is causing the trouble alarm. 78 SOLAS 04 CH. I Reg. 11.a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No. 1260.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 November 2020 Resolved
Maintenance, testing and inspections of life-saving equipment shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of such appliances. Vessel's lifeboats on port and stbd side are making contact with steel supports on the launching davits, causing damage to the hulls.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2020
Resolved 10 February 2023
Resolution: Observed lowering of the port side AFT LB and didnt see any signs that would indicate rubbing.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 November 2020 Resolved
The record under paragraph (a) of this section must be prepared at the time of the operation, certified as correct by the master or person in charge of the ship, maintained on the ship for 2 years following the operation and made available for inspection by the Coast Guard. Vessel's garbage receipt dates for discharge to shore and log book dates, as well as categories of garbage sent ashore do not match.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2020
Resolved 10 February 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 November 2020 Resolved
(1)The minimum sound-pressure levels for the emergency-alarm tone in interior and exterior spaces must be a sound level of not less than 80 dB(A) measured at 10 feet on the axis; and (2) At least 10 dB(A) measured at 10 feet on the axis, above background noise level when the vessel is underway in moderate weather unless flashing red lights are used in accordance with 46CFR113.25-10(b). Working areas throughout the engine room were unable to hear the audible general alarm when no visual alarm indicators were present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Tested general alarm and could hear throughout engine room
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 November 2020 Resolved
Where the general emergency signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm that has sufficient intensity above the background lighting that would alert personnel in the space. Working areas throughout the engine room had missing or inoperable lights where the audible alarm is unable to be heard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Tested general alarm and was able to see operational light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2020 Resolved
A nonmetallic expansion joint must be replaced 10 years after it has been placed into service if it is located in a system which penetrates the side of the vessel and both the penetration and the nonmetallic expansion joint are located below the deepest load waterline. The vessel was unable to show proof that the raw-water expansion joints had been replaced within the previous 10 years.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Expansion joint is not in a salt water system and not applicable to 10 year service life requirement
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 January 2020 Resolved
Tested fire main and noted several fire station hydranty valves leaking by charging hoses. Overhaul valves at fire stations 10, 51, 102, 112, 136, 140, 143, 144 & 146 within 30 days to class satisfaction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 16 January 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS Surveyors.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 January 2020 Resolved
Port side rescue boat air bladders deflatted. Reinflate prior to sailing to maintain operational readiness Prior to departure.
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: Resolved during inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2020 Resolved
2 life buoy plugs on port side main deck failed. Renew plugs to restore watertight integrity.
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: Repaired during inspection
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 January 2020 Resolved
02 Engineroom forced ventilation vouvers (C5 P/S) tested inoperable. Vessel directed to repair, survey, and prove proper operation of all forced vent louvers servicing the engineroom. 74 SOLAS (2001) II-2/5.2.2.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 16 January 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS Surveyors.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 15 October 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons aboard. As noted by ABS reports there are several outstanding items have been extended and vessel is authorized to sail in support of National Defense Operations. Upon completion of Military mission and unless otherwise specified the following OSRs are to be repaired at next US port after sailing foreign to satisfaction of attending Class Surveyor. OSR 1029 Sea Strainer to be renewed w/in 6 months. OSR 1067 Main Propulsion Turbo bolts - repair w/in 6mos OSR 1106 - Gas detection in D1 Cargo Hold - 40a OSR 1109 - No2 Gen Lube Oil Pump - 40a OSR 1112 - Engine 1B Jacket Water Pump - 40a OSR 1114 - Cargo Hold Secondary Bilge System frozen valves in ballast tanks - 40a. Advise Cognizant OCMI & Local US Port Class Surveyor if mission is extended.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 October 2019
Resolved 9 January 2020
Resolution: Vessel conducted needed repairs, cleared by class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 November 2018 Resolved
Vessel Engine Room fire dampers for ventilation do not shut properly, adjust or repair fire dampers to the satisfaction of the attending ABS Surveyor prior to departure from port. 74 SOLAS 01 Cons II-2/16.3.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2018
Resolved 20 November 2018
Resolution: Linkages were repaired and all the dampeners were found satisfifactory as per ABS report NN3585600
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 November 2018 Resolved
WTD 4-113-1 did not operate in all open/close methods. Repair & test door in all modes to the satisfaction of the attending ABS Surveyor prior to departure from port. 74 SOLAS 97 Cons. II-1/25-9.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2018
Resolved 20 November 2018
Resolution: WTD track was cleaned and tested in all modes and was found satisfactory to the attending ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 8 November 2018 Resolved
Sounding Tube for ballast tank 4P has pinholes in it. Make repair proposal & make temporary repairs to the satisfaction of attending ABS Surveyor within 7 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 20 November 2018
Resolution: Sounding tube cropped and renewed to satisfaction.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 8 November 2018 Resolved
Sounding Tube in Ballast Tank 6 had no flange & was open to the tank. Make repair proposal & make temporary repairs to the satisfaction of attending ABS Surveyor within 7 days. 74 SOLAS 97 Cons. I/11
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 20 November 2018
Resolution: Sounding tube cover flange was re-installed and inspected by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2018 Resolved
Ship Service Air compressors are overheating & have temporary fans on them to keep them operating. Show proper operation of air compressors to the satisfaction of attending ABS Surveyor within 7 days. 74 SOLAS 97 Cons. I/11
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 20 November 2018
Resolution: Inlet air filters were replaced and found satisfactory to ABS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2018 Resolved
Glass on remote CO2 operation control was broken for bow thruster space. Replace glass to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: The glass was replaced as original and found satisfactory to ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2018 Resolved
Fuel Supply Solenoid Electric Junction Box cover was missing. Install cover to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 97 Cons. I/11
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: Cover was replaced and found satisfactory to ABS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 November 2018 Resolved
Two bulkhead penetrations in space 03-88-3 had two different kinds of fire retardant materials used. Prove compatibility & approval or replace with a approved material to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 01 Cons. II-2/43.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: The fire retardant material installed was cleaned out in its entirety and replaced with approved material to the satisfaction of ABS
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 8 November 2018 Resolved
Condensate drain line in Fan Room 01-85-3 appeared to be leaking and approx 2" of standing water were on the aft deck of space. Make repairs to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: Temporary repairs were made to condensate drain lines to the satisfaction of ABS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 November 2018 Resolved
Fire screen door in emergency escape hatch would not latch shut. Make repairs to the satisfaction of attending ABS Surveyor within 30 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 20 November 2018
Resolution: Doors were repaired to the satisfaction od ABS.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 November 2018 Resolved
Five ventilation dampeners in cargo holds would not close completely during shut down. Those ventilation openings SS28 F-Deck, SS15 E-deck, SS25 E-deck & SS51 are to remained closed until permanent repairs can be made to the satisfaction of attending ABS Surveyor no later than 07FEB2019. 74 SOLAS 01 Cons. II-2/16.3.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2019
Resolved 9 January 2020
Resolution: Cleared in MISLE on 9Jan2020, item was addressed before last USCG inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 October 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The raw water strainer for the port main engine was discovered to be leaking sea water. Repair the sea strainer leak to the satisfaction of the Classification Society. 74 SOLAS 14 I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2018
Resolved 16 November 2018
Resolution: Sea Strainer had temporary repairs conducted on it to the satisfaction of ABS and a outstanding recomendation issued to be due at their next survey. ABS Class report number NN3564824.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018 Resolved
Vessel had failure of their No. 1 main Circulation Pump Upper Bearing Housing. Repair or Replace & show proper operation to the satisfaction of attending class surveyor prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2018
Resolved 20 November 2018
Resolution: Repairs and parts were replaced and tested to the satisfaction of ABS Surveyor as per ABS report NN3585600
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 November 2017 Resolved
crew discovered a pinhole leak at the bottom of a piping seem weld in the 20" portside raw water cooling discharge pipe. A temporary repair in the form of a make shift jubilee patch was installed to secure the leak.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 March 2018
Resolution: Vessel provided documentation that deficiency was cleared by ABS Surveyor on 16FEB2018 in Newport News, VA.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 31 July 2017 Resolved
WTD 6-33-1 was found to be inoperable in the closed and watertight position. Hydraulic leak was noted during operation. Repair hydraulics and prove proper operation of door. Cite: Class supplement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 8 September 2017
Resolution: Verified the proper operation of WTD 6-33-1, all sat
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 July 2017 Resolved
2 smoke detectors were inoperable. Repair smoke detectors and prove proper operation. cite: class supplement
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 8 September 2017
Resolution: Verified the proper operation of the two smoke detectors, all sat

Casualty record · 1

27 August 2025Routine · role: Involved in a Marine Casualty · activity 8219839
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.