NELSON V. BRITTIN

NELSON V. BRITTIN is a 2002 public vessel, unclassified. The Coast Guard has recorded 74 inspections since 2002, most recently in October 2025, along with 46 deficiencies and 1 casualty investigation in 2025.

Records from 2002 to 2025. Most recent: inspection, 22 October 2025.

Built
2002
Last inspected
22 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9193575 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-1287

Inspections, by type

…with no type recorded18
Years with a record 21 calendar years (2002–2025)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
Registered tonnagegross 69,365 / net 20,809
ITC dimensions (L × B × D)890.3 ft × 105.8 ft × 90.3 ft
ITC tonnagegross 69,365 / net 20,809
BuilderAVONDALE SHIPYARD · Avondale, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20809 - Convention (Subpart B), Net Ton
69365 - Convention (Subpart B), Gross Ton
29151 - Dead Weight, Ton
58255 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 74

22 October 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8255917
29 August 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8220800
27 August 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8219140
27 August 2025 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8219839
12 March 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8092410
25 September 2024 Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8010731
10 March 2023 Deficiency Check · In-Service Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7667291
10 August 2022 Administrative Inspection · ACP Drydock Oversight · ACP COI Oversight · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7530587
25 May 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7459338
7 September 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7305924
6 November 2020 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7090758
9 January 2020 Deficiency Check · ACP Additional Oversight – Risk Assessment · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6881759
15 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6834728
14 July 2019 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6747443
4 July 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6753618
24 December 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6603559
8 November 2018 Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6572164
16 October 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6562901
15 October 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6561233
10 October 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6558983
28 September 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6550526
14 September 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6540730
12 September 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6550854
7 March 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6367849
21 December 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6327547
30 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6315407
24 November 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6312196
8 November 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6304950
6 September 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6261126
31 July 2017 Re-Inspection · Administrative Inspection · ACP COI Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6226561
12 May 2017 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6148676
24 February 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821214
26 August 2015 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5214666
18 August 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4958727
17 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4958775
16 August 2014 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4956730
26 September 2011 ACP Annual Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4162801
9 September 2010 ACP Annual Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3854356
1 October 2008 ACP Annual Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3337138
5 February 2008 MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3142338
1 November 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3091174
14 September 2007 MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Activities Europe · Activity 3055695
5 September 2007 Type not recorded
No type recorded · Activities Europe · Activity 3206040
12 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2993427
5 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2996908
20 April 2007 Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2911527
8 August 2006 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2740025
28 July 2006 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2728101
6 December 2005 ACP Annual Oversight
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2538739
7 September 2005 Type not recorded
No type recorded · Activities Europe · Activity 2592420
15 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2427816
19 May 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2362337
26 March 2005 Type not recorded
No type recorded · Activities Europe · Activity 2323483
2 December 2004 ACP Annual Oversight
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2251172
8 September 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2190070
24 August 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2206277
27 July 2004 Type not recorded
No type recorded · Activities Europe · Activity 2171963
22 July 2004 Damage Survey
Physical examination · Activities Europe · Activity 2141177
23 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2108052
5 May 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2059667
26 April 2004 Type not recorded
No type recorded · Activities Europe · Activity 2095151
24 February 2004 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2823878
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997055
24 December 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1969227
10 December 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2015958
9 December 2003 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1961107
24 November 2003 ACP COI Oversight · Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1953595
18 June 2003 Type not recorded
No type recorded · Activities Europe · Activity 2009774
20 March 2003 Administrative Inspection · Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1759978
1 February 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1739573
30 January 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1737796
30 January 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1804646
30 December 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1726905
11 July 2002 Internal Structural Exam · Hull Examination · Initial Certification · Construction Oversight
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1637488

Deficiency record · 46

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 March 2023 Resolved
Unless expressly provided otherwise or unless, in the opinion of the Administration having regard for particular voyages on which the ship is constantly engaged, other requirements are appropriate, all life-saving appliances prescribed in this part shall: be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. Life boats were found to have faded retro-reflective material on the top side of all boats. Replace to satisfaction of ABS. 74 SOLAS (97) III/34; LSA 2/1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 18 September 2023
Resolution: Received ABS report
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 March 2023 Resolved
A fireman's outfit shall consist of: personal equipment comprising: An axe to the satisfaction of the administration. During fire drill, firefighters were not issued fire axes. One axe was presented that was not an insulated fire axe. Provide approved fire axes, such as those required by FSS 3/2.1.1.1.5, or equivalent for each fireman's outfit to the satisfaction of ABS. 74 SOLAS (97) II-2/17.1.1.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 18 September 2023
Resolution: Received ABS report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2023 Resolved
"Trouble" alarm became active during operational testing of the fire detection system and this alarm could not be cleared prior to completion of the COI Exam.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 10 February 2023
Resolution: Deficiency absorbed by ABS, finding number entered above.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 10 February 2023 Resolved
Every oil tanker of 150 gross tonnage and above and every ship of 400 gross tonnage and above other thanan oil tanker shall be provided with an oil record book part 1 (machinery space operations). MI noted in past Oil Record Book a letter from the company stating a 3rd Engineer eronously entered multiple entries into Oil Record Book that did not align with tank ullages or quantities transferred between tanks.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 February 2023
Resolution: ABS issued PR-17 and is initiating further investigation of onboard procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2022 Resolved
Vessel experienced loss of propulsion due to a cracked turbocharger on one MDE and inability to clutch-in on another MDE. A vessel enrolled in the ACP program must comply with applicable class rules for the proper operational status of propulsion machinery. VSL shall not proceed beyond the boundary line until reapirs on the 02 inoperable MDEs are effected to the satisfaction of class and a preliminary report is provided to the CG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2022
Resolved 27 May 2022
Resolution: ABS surveyor attended vessel and verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 7 September 2021 Resolved
Every lifeboat shall have food ration as described in paragraph 4.1.5.1.18 totalling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging. Inspectors found several rations to have lost their airtight packaging. Vessel to ensure each person the lifeboat is permitted has 10,000 kJ. 74SOLAS(09/14)111/34 LSA Ch. IV 4.4.8
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 28 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021 Resolved
The machinery, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended. A hose on the OWS is leaking. Replace hose IAW manufacture specifications. 78 SOLAS 04 Ch. II-1 Reg. 26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No. 1257.0
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2021 Resolved
Fire detection and alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The fire alarm panel in the engine control room is showing a trouble alarm. Correct the fault that is causing the trouble alarm. 78 SOLAS 04 CH. II-1 Reg 14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No 1258
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021 Resolved
In cargo ships, ventilation fans shall normally be run continuously whenever vehicles are on board. Where this is impracticable, they shall be operated for a limited period daily as weather permits and in any case for a reasonable period prior to discharge, after which period the ro-ro or vehicle space shall be proved gas-free. One or more portable combustible gas detecting instruments shall be carried for this purpose. The combustible gas detector in Hold #5 has a sensor fault. Repair fault to ensure proper system operation. 78 SOLAS 04 CH. II-1 Reg 20.3.1.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No 1259.0
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The refrigerant detector is showing a trouble alarm. Correct the fault that is causing the trouble alarm. 78 SOLAS 04 CH. I Reg. 11.a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2021
Resolved 27 October 2021
Resolution: ABS finding No. 1260.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 November 2020 Resolved
Maintenance, testing and inspections of life-saving equipment shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of such appliances. Vessel's lifeboats on port and stbd side are making contact with steel supports on the launching davits, causing damage to the hulls.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2020
Resolved 10 February 2023
Resolution: Observed lowering of the port side AFT LB and didnt see any signs that would indicate rubbing.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 November 2020 Resolved
The record under paragraph (a) of this section must be prepared at the time of the operation, certified as correct by the master or person in charge of the ship, maintained on the ship for 2 years following the operation and made available for inspection by the Coast Guard. Vessel's garbage receipt dates for discharge to shore and log book dates, as well as categories of garbage sent ashore do not match.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2020
Resolved 10 February 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 November 2020 Resolved
(1)The minimum sound-pressure levels for the emergency-alarm tone in interior and exterior spaces must be a sound level of not less than 80 dB(A) measured at 10 feet on the axis; and (2) At least 10 dB(A) measured at 10 feet on the axis, above background noise level when the vessel is underway in moderate weather unless flashing red lights are used in accordance with 46CFR113.25-10(b). Working areas throughout the engine room were unable to hear the audible general alarm when no visual alarm indicators were present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Tested general alarm and could hear throughout engine room
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 November 2020 Resolved
Where the general emergency signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm that has sufficient intensity above the background lighting that would alert personnel in the space. Working areas throughout the engine room had missing or inoperable lights where the audible alarm is unable to be heard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Tested general alarm and was able to see operational light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2020 Resolved
A nonmetallic expansion joint must be replaced 10 years after it has been placed into service if it is located in a system which penetrates the side of the vessel and both the penetration and the nonmetallic expansion joint are located below the deepest load waterline. The vessel was unable to show proof that the raw-water expansion joints had been replaced within the previous 10 years.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2021
Resolution: Expansion joint is not in a salt water system and not applicable to 10 year service life requirement
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 January 2020 Resolved
Tested fire main and noted several fire station hydranty valves leaking by charging hoses. Overhaul valves at fire stations 10, 51, 102, 112, 136, 140, 143, 144 & 146 within 30 days to class satisfaction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 16 January 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS Surveyors.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 January 2020 Resolved
Port side rescue boat air bladders deflatted. Reinflate prior to sailing to maintain operational readiness Prior to departure.
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: Resolved during inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2020 Resolved
2 life buoy plugs on port side main deck failed. Renew plugs to restore watertight integrity.
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: Repaired during inspection
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 January 2020 Resolved
02 Engineroom forced ventilation vouvers (C5 P/S) tested inoperable. Vessel directed to repair, survey, and prove proper operation of all forced vent louvers servicing the engineroom. 74 SOLAS (2001) II-2/5.2.2.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 16 January 2020
Resolution: Deficiency rectified to the satisfaction of the attending ABS Surveyors.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 15 October 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons aboard. As noted by ABS reports there are several outstanding items have been extended and vessel is authorized to sail in support of National Defense Operations. Upon completion of Military mission and unless otherwise specified the following OSRs are to be repaired at next US port after sailing foreign to satisfaction of attending Class Surveyor. OSR 1029 Sea Strainer to be renewed w/in 6 months. OSR 1067 Main Propulsion Turbo bolts - repair w/in 6mos OSR 1106 - Gas detection in D1 Cargo Hold - 40a OSR 1109 - No2 Gen Lube Oil Pump - 40a OSR 1112 - Engine 1B Jacket Water Pump - 40a OSR 1114 - Cargo Hold Secondary Bilge System frozen valves in ballast tanks - 40a. Advise Cognizant OCMI & Local US Port Class Surveyor if mission is extended.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 October 2019
Resolved 9 January 2020
Resolution: Vessel conducted needed repairs, cleared by class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 November 2018 Resolved
Vessel Engine Room fire dampers for ventilation do not shut properly, adjust or repair fire dampers to the satisfaction of the attending ABS Surveyor prior to departure from port. 74 SOLAS 01 Cons II-2/16.3.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2018
Resolved 20 November 2018
Resolution: Linkages were repaired and all the dampeners were found satisfifactory as per ABS report NN3585600
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 November 2018 Resolved
WTD 4-113-1 did not operate in all open/close methods. Repair & test door in all modes to the satisfaction of the attending ABS Surveyor prior to departure from port. 74 SOLAS 97 Cons. II-1/25-9.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2018
Resolved 20 November 2018
Resolution: WTD track was cleaned and tested in all modes and was found satisfactory to the attending ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 8 November 2018 Resolved
Sounding Tube for ballast tank 4P has pinholes in it. Make repair proposal & make temporary repairs to the satisfaction of attending ABS Surveyor within 7 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 20 November 2018
Resolution: Sounding tube cropped and renewed to satisfaction.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 8 November 2018 Resolved
Sounding Tube in Ballast Tank 6 had no flange & was open to the tank. Make repair proposal & make temporary repairs to the satisfaction of attending ABS Surveyor within 7 days. 74 SOLAS 97 Cons. I/11
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 20 November 2018
Resolution: Sounding tube cover flange was re-installed and inspected by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2018 Resolved
Ship Service Air compressors are overheating & have temporary fans on them to keep them operating. Show proper operation of air compressors to the satisfaction of attending ABS Surveyor within 7 days. 74 SOLAS 97 Cons. I/11
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 20 November 2018
Resolution: Inlet air filters were replaced and found satisfactory to ABS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2018 Resolved
Glass on remote CO2 operation control was broken for bow thruster space. Replace glass to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: The glass was replaced as original and found satisfactory to ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2018 Resolved
Fuel Supply Solenoid Electric Junction Box cover was missing. Install cover to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 97 Cons. I/11
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: Cover was replaced and found satisfactory to ABS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 November 2018 Resolved
Two bulkhead penetrations in space 03-88-3 had two different kinds of fire retardant materials used. Prove compatibility & approval or replace with a approved material to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 01 Cons. II-2/43.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: The fire retardant material installed was cleaned out in its entirety and replaced with approved material to the satisfaction of ABS
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 8 November 2018 Resolved
Condensate drain line in Fan Room 01-85-3 appeared to be leaking and approx 2" of standing water were on the aft deck of space. Make repairs to the satisfaction of attending ABS Surveyor within 14 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: Temporary repairs were made to condensate drain lines to the satisfaction of ABS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 November 2018 Resolved
Fire screen door in emergency escape hatch would not latch shut. Make repairs to the satisfaction of attending ABS Surveyor within 30 days. 74 SOLAS 97 Cons. I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 20 November 2018
Resolution: Doors were repaired to the satisfaction od ABS.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 November 2018 Resolved
Five ventilation dampeners in cargo holds would not close completely during shut down. Those ventilation openings SS28 F-Deck, SS15 E-deck, SS25 E-deck & SS51 are to remained closed until permanent repairs can be made to the satisfaction of attending ABS Surveyor no later than 07FEB2019. 74 SOLAS 01 Cons. II-2/16.3.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2019
Resolved 9 January 2020
Resolution: Cleared in MISLE on 9Jan2020, item was addressed before last USCG inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 October 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The raw water strainer for the port main engine was discovered to be leaking sea water. Repair the sea strainer leak to the satisfaction of the Classification Society. 74 SOLAS 14 I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2018
Resolved 16 November 2018
Resolution: Sea Strainer had temporary repairs conducted on it to the satisfaction of ABS and a outstanding recomendation issued to be due at their next survey. ABS Class report number NN3564824.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018 Resolved
Vessel had failure of their No. 1 main Circulation Pump Upper Bearing Housing. Repair or Replace & show proper operation to the satisfaction of attending class surveyor prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2018
Resolved 20 November 2018
Resolution: Repairs and parts were replaced and tested to the satisfaction of ABS Surveyor as per ABS report NN3585600
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 November 2017 Resolved
crew discovered a pinhole leak at the bottom of a piping seem weld in the 20" portside raw water cooling discharge pipe. A temporary repair in the form of a make shift jubilee patch was installed to secure the leak.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 March 2018
Resolution: Vessel provided documentation that deficiency was cleared by ABS Surveyor on 16FEB2018 in Newport News, VA.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 31 July 2017 Resolved
WTD 6-33-1 was found to be inoperable in the closed and watertight position. Hydraulic leak was noted during operation. Repair hydraulics and prove proper operation of door. Cite: Class supplement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 8 September 2017
Resolution: Verified the proper operation of WTD 6-33-1, all sat
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 July 2017 Resolved
2 smoke detectors were inoperable. Repair smoke detectors and prove proper operation. cite: class supplement
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 8 September 2017
Resolution: Verified the proper operation of the two smoke detectors, all sat
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 August 2015 Resolved
Perform Fire, Abandon ship and boat drills with entire crew prior to activation, to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 25 February 2016
Resolution: Conducted satisfactory fire, abandon ship, and boat drills.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 9 September 2010 Resolved
A data analysis completed by DPS offsore of the vessels SVDR revealed that the vessels heading information was not being recorded by the SVDR.
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 28 September 2010
Resolution: Vessels SVDR repaired and is operating properly.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 14 September 2007 Resolved
Amend the automation test procedure to add the procedures for SSDG low lube oil, high jacket water, and overspeed test. Add the procedures to test the main diesel engine overspeeds electronically, or perform periodic tests mechanically as specified in the current procedures. Maintain a copy of the approved procedures onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2007
Resolved 18 September 2007
Resolution: Received email from Chief Engineer, [name withheld] advising of manufacturer''''''''s procedure for conducting the overspeed overspeed, lube oil, and high temp test. Which is now in the ATP, but he was unclear with.
Engineering › Steering Gear System › Rudder
Issued 28 July 2006 Resolved
Divers conducting under hull cleaning discovered a 20" x 30" hole in the bottom plate of the stbd rudder. Marine growth indicated this had existed for some time.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 October 2006
Resolution: All repairs complete.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 24 November 2003 Resolved
Replace burnt-out bulb on fixed CO2 indicator in engineroom escape trunk.
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 24 December 2003
Resolution: Burnt out bulbs have been replaced on CO2 indicator in engineroom escape trunk.
Fire Fighting › Structural Fire Protection - General
Issued 24 November 2003 Resolved
Properly repair fire stop in stair tower on "D" eck leading to engine room casing port side.
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 24 December 2003
Resolution: Fire stop has been properly repaired in the stair tower on "D" Deck leading to engine room casing port side.
Engineering › Steam System (auxiliary) › Piping
Issued 24 November 2003 Resolved
Make proper repair to steam return line, starboard side, engineroom (lower level).
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 25 March 2004
Resolution: Repairs made to satisfaction of attending classification society surveyor.
Engineering
Issued 24 November 2003 Resolved
Remove welding cable from shore tie connection room.
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 24 December 2003
Resolution: Welding cable was removed from shore tie connection room.
Engineering › Thrusters › Seal
Issued 24 November 2003 Resolved
Make proper repairs and test "sat" the # 2 bow thruster.
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 24 December 2005
Resolution: Deficiency issued by MSO Hampton Roads. ABS SafeNet documentation illustrated class recommendations. #2 Bow thruster operative. Permanent repairs to be made at dry dock by 10 Jul 2007. New deficiency will be issued corresponding with the 2007 date.
Lifesaving
Issued 11 July 2002 Resolved
Complete Satisfactory Fire and Boat Drills to the satisfaction of the attending Marine Inspector. Complete satisfactory knowledge and operational test of the automation systems. LEGACY COMPONENT DESC: Drills
Due 11 September 2002
Resolved 5 August 2002

Casualty record · 1

27 August 2025Routine · role: Involved in a Marine Casualty · activity 8219839
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.