COSCO AMERICA is a 2008 freight ship. The Coast Guard has recorded 13 inspections since 2014, most recently in December 2023, along with 2 deficiencies.
Records from 2014 to 2023. Most recent: inspection, 9 December 2023.
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for COSCO AMERICA, retrieved 18 September 2026. mauryrecords.com/v/psix-1288386.html
Documentation record
Tonnage as PSIX records it54951 - Convention (Subpart B), Net Ton 109968 - Dead Weight, Metric Ton 147723 - Displacement, Metric Ton 114394 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
9 December 2023PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7836825
9 May 2023PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7684207
9 September 2021PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7302479
20 November 2019ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6859189
7 October 2019Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6830110
30 August 2019Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6799048
19 July 2019In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6755382
6 August 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6502511
17 July 2017PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6211765
74SOLAS(04) 1/11a
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs found damage to the forward inboard container mount on Bay 50 Row 17 Tier 82.
Code 40AC
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2019
Resolved 28 August 2019
Resolution: Recieved satisfactory class report atttesting to repairs.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 21 September 2015Resolved
74 SOLAS (2009 cons ed)II-2/9.3.3.1 Where "A" class divisions are penetrated, such penetrations shall be tested in accordance with the fire test procedures code. Found multiple penetrations through "A" class divisions on the E and F deck within the pipe duct rooms. 40(a)(c)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 October 2015
Resolution: Received Class survey attesting to the repairs of penetrations in class A boundaries.