Records from 1988 to 2003. Most recent: inspection, 25 March 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
25 March 2003
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1762412
9 December 2002
Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1719201
8 December 2002
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1743874
9 May 2002
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1614714
11 February 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1486011
29 January 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1480910
27 December 2001
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1473958
26 November 2001
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1376666
23 October 2000
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361768
22 December 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1046771
3 December 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 809854
18 October 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361190
10 September 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1119590
27 July 1999
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361004
4 June 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803471
9 May 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1129098
9 November 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803267
7 October 1998
Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1375512
8 August 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 173721
5 April 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 212123
9 December 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780413
24 October 1997
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1114031
16 September 1997
Examination of Repairs
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1107644
15 August 1997
Examination of Repairs · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1371957
25 February 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 139933
2 January 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1096664
6 November 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1171904
24 October 1996
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1161192
18 January 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1184834
15 November 1995
Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1458252
17 October 1994
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1180838
18 February 1994
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 853607
14 December 1993
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1354547
15 July 1993
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 846480
27 April 1993
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 832104
26 April 1993
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 831819
26 April 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 832103
1 April 1993
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 835321
9 December 1992
Drydock Extension · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1135243
9 December 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1135244
18 November 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 933229
17 October 1991
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 941286
1 October 1991
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 941060
17 March 1991
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 916337
12 December 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1237281
16 April 1990
Drydock Extension
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1239936
17 October 1988
Initial Certification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 902248
17 October 1988
Hull Examination · Re-Inspection · Drydock Extension
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1231833
Communications › Radio Communications
Issued 27 December 2001
Resolved
Provide current FCC Safety Radiotelephoney Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 29 January 2002
Resolution: FCC certificate obtained.
Engineering › Bilge Water Management System
Issued 27 December 2001
Resolved
Demonstrate proper operation of port ama automatic bilge pump indicator light located by engine controls.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 29 January 2002
Resolution: Indicator light works.
Electrical › Lighting (emergency)
Issued 27 December 2001
Resolved
Demonstrate proper operation of two portable lights. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 29 January 2002
Resolution: Portable flashlights on board.
Engineering › Fuel Oil Service System
Issued 27 December 2001
Resolved
Replace plastic plugs on raycor fuel filter bowls with metal plugs. LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 29 January 2002
Resolution: Proper plugs installed.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 27 December 2001
Resolved
Properly secure main deck seating. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 29 January 2002
Resolution: Seats secured.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 27 December 2001
Resolved
Demonstrate proper operation of engine compartment fixed firefighting system audible and visual indicators. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2002
Resolved 29 January 2002
Resolution: Unit functions properly.
Operations/Management › Drug and Alcohol Testing
Issued 27 December 2001
Resolved
Contact USCG DAPI Program Manager at MSO Guam for an audit of company drug and alcohol program. LEGACY COMPONENT DESC: Employee Coverage
Condition: Unknown
Due 21 January 2002
Resolved 29 January 2002
Resolution: Audit conducted.
Lifesaving › Buoyant Apparatus
Issued 27 December 2001
Resolved
Replace both buoyant apparatus and existing lifefloat with new lifefloats of sufficient capacity for 50% of vessel capacity. In lieu of lifefloats, vessel may carry a 406 MHZ Class A EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Vessel has a CG approved EPIRB on board.
Unknown
Issued 23 October 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 October 2000
Resolved 24 October 2000
Lifesaving
Issued 23 October 2000
Resolved
Reattach missing pendants to buoyant apparatus beckets. Pendants to be 12 foot long, made of 1/4-inch dark colored material with a minimum breaking strength 540 lbs., and secured up in a hank. Details are available in 46 CFR 160.010-4.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Documentation
Issued 23 October 2000
Resolved
Prove compliance with FCC Radio Operators Permit. At least one crewmember must be on board with a valid FCC Radio Operator's Permit whenever the vessel is underway with passengers on board.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Lifesaving
Issued 23 October 2000
Resolved
Make approved repairs to weather "cracking" on all life floats and buoyant apparatuses.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Unknown
Issued 23 October 2000
Resolved
Vessel owners to provide MSO Guam with correct mailing address, phone numbers, and points of contact for both vessel owner and for vessel operator. This information is needed for official purpose, i.e., Certificate of Inspection, inspection notices, etc.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Documentation
Issued 23 October 2000
Resolved
Prove proper documentation of vessel. Vessel owner to initiate documentation procedures for ownership change.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Fire Fighting
Issued 23 October 2000
Resolved
Provide proof of annual servicing of vessel's engine space fixed fire- extinguishing system.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Fire Fighting
Issued 23 October 2000
Resolved
Post operating instructions at helm and at pull station for the engine space fixed fire-extinguishing system.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Electrical
Issued 23 October 2000
Resolved
Install MSD system electrical wire connections in a electrical box.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Construction/Loadline
Issued 23 October 2000
Resolved
Investigate and correct low audible sound for bilge high-level alarm indicator.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Fire Fighting
Issued 23 October 2000
Resolved
Provide proper mount for A-II/B-I portable fire extinguisher located in aftcompartment.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Lifesaving
Issued 23 October 2000
Resolved
Replace three distress flares and 6 smoke signals that have expired. Signal devices to meet CG approval numbers 160.021 (flare) and 160.037 (smoke), or acceptable substitutions, for commercial vessel service.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Navigation
Issued 23 October 2000
Resolved
Update Island of Guam Chart with new Agat Marina Entrance Buoy. - Entrance Lighted Buoy 1, position 13 21 58N, 144 38 39E, Q G characteristics, 4 milevisibility, Green in color.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Lifesaving
Issued 23 October 2000
Resolved
Prove proper operation of buoyant apparatus water light that will not light.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Fire Fighting
Issued 18 October 1999
Resolved
Prove operation of fixed fire extinguishing system to the satisfaction of attending CG marine inspector.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Engineering
Issued 18 October 1999
Resolved
Prove operation of engine lube oil pressure gauge at helm.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Lifesaving
Issued 18 October 1999
Resolved
Replace ring life buoy waterlight housing that is fractured.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Lifesaving
Issued 18 October 1999
Resolved
Provide proof that quarterly man overboard and fire drills are being conducted, along with periodic lifesaving appliance maintenance checks.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Engineering
Issued 27 July 1999
Resolved
Renew propulsion shaft cutlass bearing and shaft zinc.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Fire Fighting
Issued 27 July 1999
Resolved
Install approved fixed fire extinguishing system in engine space. System to meet requirements of 46 CFR 181.400.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Unknown
Issued 27 July 1999
Resolved
Replace missing toggle bolts in aft cabin rear window hatch.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 4 June 1999
Resolved
Install a bilge high level indicating device in each watertight compartmentin amas and main hull. This device shall provide both audible and visual alarms at the vessel operating station.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Fire Fighting
Issued 4 June 1999
Resolved
Install an approved fixed fire extinguishing system, meeting requirements of 46 CFR 181.400, for main engine space. System shall operate in both manual and automatic modes. Vessel COI will be revoked and vessel limited to not more than 6 passengers if the system is not installed by 15JUL99.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Fire Fighting
Issued 9 May 1999
Resolved
Provide proof of purchase of a fixed fire extinguishing system, meeting requirements of 46 CFR 181.400, for each space containing an internal combustion engine. Vessel COI will be revoked and vessel limited to not more than 6 passengers without proof of purchase by 28MAY99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Construction/Loadline
Issued 9 May 1999
Resolved
Provide proof of installation of bilge hi-level alarm & indicators meeting 46 CFR 182.530 for each space with a through hull fitting, machinery space,or space with a non-watertight hatch. Vessel COI will be revoked & vessel limited to nmt 6 passengers, without proof of installation by 10JUN99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Lifesaving
Issued 7 October 1998
Resolved
Obtain a new approved 1st aid kit, or restock present 1st aid kit with the required items.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Log vessel fire and man overboard drills in vessel log. Log entries to describe drill, attendees, and actions taken. Drills to be conducted at a minimum of every three months.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Replace non-approved smoke pyro signal devices with devices that are approved for commercial vessel use.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Log in a vessel log the weekly, monthly and annual inspections of all safety and lifesaving gear, including 1st aid kit.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Obtain two more adult lifejackets to bring the total count of adult pfds upto 48. Until such time the jackets are on board, the vessel shall be limited to not more than 46 total persons.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Engineering
Issued 7 October 1998
Resolved
Install 30 x 30 mesh screen in fuel oil tank vent.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Construction/Loadline
Issued 7 October 1998
Resolved
Obtain a portable bilge pump and associated hoses capable of dewatering anycompartment of the vessel.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Install retroreflective tape to the vessel's ring life buoy.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Obtain and post a lifejacket donning placard for the second style of lifejacket carried on board the vessel.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Construction/Loadline
Issued 7 October 1998
Resolved
Provide means to make forward hatch watertight.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Unknown
Issued 7 October 1998
Resolved
Provide proof of employee training on drug and alcohol abuse.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Construction/Loadline
Issued 7 October 1998
Resolved
Replace the white plastic hose on the discharge side of the "Rule" electricsubmersible bilge pumps with a heavy duty reinforced discharge hose. All hose connections to be double clamped.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Construction/Loadline
Issued 7 October 1998
Resolved
Install a positive shutoff valve in the bilge pump discharge line. Valve to be of metallic construction, and shall be located near as possible to the through hull fitting.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Mark escape hatches for fwd and aft compartments.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Provide means to open forward and aft compartment escape hatches from inside and outside the compartment.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 7 October 1998
Resolved
Install ring life buoy in an area on the main deck, and make ready for immediate use.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Documentation
Issued 24 October 1997
Resolved
Establish a Waste Management Plan for the vessel. The plan shall meet the requirements of 33 CFR 151.57.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Provide retaining mechanism for shift yoke to clutch pin in way of engine clutch.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Construction/Loadline
Issued 24 October 1997
Resolved
Relocate bilge pump run indicator lights to an area near the control station to comply with 46 CFR 182.530(c).
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Navigation
Issued 24 October 1997
Resolved
Post the Emergency Broadcast Instruction placard in accordance with 46 CFR 184.506 and 184.510.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Provide a crew to get the vessel underway to allow the CG inspector to witness a man overboard drill, along with observing the workings of the vessel structure.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Log all man overboard and firefighting drills and training in accordance with 46 CFR 185.520 and 180.524. Crew training for other emergencies and for normal duties shall also be logged in accordance with 46 CFR 185.420.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Provide proper 30 x 30 mesh flame screen for the fuel tank vent in accordance with 46 CFR 182.455(b)(6).
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Navigation
Issued 24 October 1997
Resolved
Obtain bell for vessel to bring into compliance with 33 COLREGS (Rules of the Road).
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Post a life jacket donning placard for each style of life jacket carried onboard the vessel. Requirements can be found in 46 CFR 185.516.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Mark vessel name on the paddles for the life float.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Unknown
Issued 24 October 1997
Resolved
Mark vessel name in at least 4" lettering on both sides of the bow in accordance with 46 CFR 67.123. Vessel name shall be in contrasting colors.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Provide vessel with two portable emergency lights, one near the helm, the other outside the engine space to comply with 46 CFR 183.432. Two flashlights of normal power will meet this requirement.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Mark fuel tank shut off valve in accordance with 46 CFR 185.608.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Double clamp all sea water cooling water lines to the engine and strainer.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Provide a bonding wire/cable between the fuel tank filling connection and the fuel tank proper in accordance with 46 CFR 182.450.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Double clamp fuel fill hose at both the fill connection fitting and at the tank fitting to comply with 46 CFR 182.435.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Unknown
Issued 24 October 1997
Resolved
Prove compliance with the DOT/CG mandated Drug and Alcohol Testing Program in accordance with 46 CFR 16. Vessel is to be in compliance with this program no later than 24 November 1997.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Post an Emergency Instruction List concerning actions to take during an emergency concerning the following: fire; man overboard; flooding. The list shall address the particular equipment, arrangement, and operation of the vessel. General guidlines can be found in 46 CFR 185.512
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Attach proper line to the ring buoy. Line shall be 60 feet in length, buoyant, non-kinking, 5/16" minimal diameter, and dark in color. Further requirements can be found in 46 CFR 180.70.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Engineering
Issued 24 October 1997
Resolved
Provide proper end fittings for all fuel lines, along with approved hose meeting SAE J-1942 or other Commandant approved hose, in accordance with 46CFR 182.720.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Attach water lights to buoyant apparatus and life float per 46 CFR 180.175 (c) and (d).
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 24 October 1997
Resolved
Obtain 10 more adult life jackets for the vessel to bring total up to 48 total adult jackets. Vessel shall be limited to no more than 38 total persons until such time that the jackets are on board.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 24 October 1996
Resolved
Provide Certificate of Documentation, maintain original onboard vessel.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Unknown
Issued 24 October 1996
Resolved
Show proof of compliance with DOT/CG mandated Drug and Alcohol Testing Program.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Documentation
Issued 24 October 1996
Resolved
Obtain inspection and FCC Communications Act Safety Radiotelephony Certificate.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Fire Fighting
Issued 15 November 1995
Resolved
Relocate one of the B-I portable extinguishers from the aft cabin to pilot control station.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Lifesaving
Issued 15 November 1995
Resolved
Seperate child sized lifejackets from adult lifejackets, properly lable by type and number the lifejacket locations.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Documentation
Issued 15 November 1995
Resolved
Provide FCC Safety Radiotelephone Certificate or proof of application for FCC inspection of radio gear.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
Provide portable 5 gpm portable bilge pump.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Documentation
Issued 17 October 1994
Resolved
PROVIDE PROOF OF NEGATIVE DRUG TEST RESULTS.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Fire Fighting
Issued 17 October 1994
Resolved
SERVICE OR REPLACE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Electrical
Issued 17 October 1994
Resolved
REWIRE ALL SHIPBOARD WIRE TO NO LESS THAN 14 GAUGE WIRE WITH CRIMPED OR SOLDERED CONNECTIONS.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Documentation
Issued 15 July 1993
Resolved
PROVIDE PROOF OF ORIGINAL DOCUMENTATION ONBOARD VESSEL.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Lifesaving
Issued 17 October 1991
Resolved
PLACE RETROFLECTIVE TAPE ON 13 ADULT LIFE JACKETS AND PLACE VESSEL NAME ON_x001C_2 CHILDS LIFE JACKETS.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Lifesaving
Issued 17 October 1991
Resolved
PROVIDE A WATER LIGHT FOR THE RING LIFE BUOY.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Lifesaving
Issued 17 October 1991
Resolved
PROVIDE (3) RED AND (3) ORANGE HAND HELD FLARES.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Documentation
Issued 17 October 1988
Resolved
PROVIDE PROPER DOCUMENTATION FOR THE VESSEL.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Navigation
Issued 17 October 1988
Resolved
REPAIR STERN NAVIGATION LIGHT.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Unknown
Issued 17 October 1988
Resolved
REMOVE B-B-Q ON STERN OF THE VESSEL.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Unknown
Issued 17 October 1988
Resolved
CONNECT MSD DISCHARGE PIPE TO THE HOLDING TANK.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988
Lifesaving
Issued 17 October 1988
Resolved
STOW LIFE PRESERVERS AS REQUIRED BY 46 CFR 180.25-10.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988