SHANDONG HAI WANG is a 2014 freight ship. The Coast Guard has recorded 8 inspections since 2014, most recently in September 2024, along with 2 deficiencies.
Records from 2014 to 2024. Most recent: inspection, 17 September 2024.
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for SHANDONG HAI WANG, retrieved 18 September 2026. mauryrecords.com/v/psix-1288709.html
Documentation record
Tonnage as PSIX records it26095 - Convention (Subpart B), Net Ton 61796 - Dead Weight, Ton 75446 - Displacement, Ton 41605 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
17 September 2024PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7997827
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 October 2020Resolved
74SOLAS(14)II-2/44.2 Each vessel generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three starts. The emergency generator was unable to start with the battery due to a faulty connection at the battery terminal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2020
Resolution: Crew replaced the battery terminal connection.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 October 2020Resolved
33CFR159.83 Each sewage retention device must have a means of indicating when the device is more than 3/4 full by volume. The crew was not using the level indictor and had the sewage hatch cover open to check the level.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 October 2020
Resolution: Crew closed tank hatch opening.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.