← All vessels
BLACKHAWK
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named BLACKHAWK
BLACKHAWK is a 1974 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1987, most recently in March 2026, along with 213 deficiencies, 1 operational control and 1 casualty investigation in 2004.
Records from 1987 to 2026. Most recent: inspection, 20 March 2026.
- Built
- 1974
- Last inspected
- 20 March 2026
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 213 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2004
Identity
557756
WDF4022
128989
Flag
UNITED STATES
367446980
Maury page id
psix-128989
Inspections, by type
…with no type recorded5
Years with a record
38 calendar years (1987–2026)
The 86 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.7 ft × 21.7 ft × 6.9 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNIANTIC, CT
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN7335MMSI 367446980 · active · compulsorily equipped · granted 12 April 2023, expires 12 April 2033
WDL6879MMSI 367446980 · cancelled · compulsorily equipped · granted 21 July 2020, cancelled 6 April 2023 · licensed under a name not among this hull’s recorded names (not shown)
EX249MMSI 367446980 · expired · exemption · granted 5 March 2019, cancelled 13 June 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDF4022MMSI 367446980 · expired · compulsorily equipped · granted 13 April 2010, cancelled 13 June 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCZ7516MMSI not assigned · expired · compulsorily equipped · granted 12 April 2000, cancelled 12 June 2010
WCF3330MMSI not assigned · expired · compulsorily equipped · granted 11 April 1994, cancelled 13 June 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 86
20 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327239
5 June 2025
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8153168
5 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8128781
26 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7897663
8 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7860767
8 February 2024
Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7862862
5 June 2023
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7704022
17 April 2023
Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7670260
6 February 2023
Annual Inspection
Physical examination · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7632701
1 December 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7602142
21 April 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7449845
16 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7367311
12 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7331655
22 January 2021
Construction Oversight · Deficiency Check · Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7128861
28 October 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7085655
6 July 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6998718
4 December 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6867438
16 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6835025
8 April 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6663036
17 August 2018
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6514690
20 March 2018
Deficiency Check · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6390897
26 September 2017
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6275095
5 June 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6160370
20 April 2016
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5858241
14 September 2015
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5718613
6 August 2015
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5207733
26 June 2014
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4900046
21 June 2012
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4351278
15 May 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4312178
1 February 2010
Administrative Inspection · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3658402
14 May 2009
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3475417
13 May 2008
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3204839
7 September 2007
Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3051819
14 May 2007
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2924509
9 May 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2643907
13 September 2005
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2491334
14 February 2005
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2289346
14 October 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2295037
24 June 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2113917
14 June 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2097643
26 January 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1993161
5 November 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1929624
14 April 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1774294
17 March 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1759484
15 August 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1658422
14 November 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441911
3 July 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1067041
4 June 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1070606
7 May 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1370132
20 April 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048878
6 March 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376072
8 February 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1045678
14 December 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 812820
7 December 1999
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1399283
1 December 1999
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1424842
8 March 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1411829
26 May 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 791600
13 March 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122301
13 March 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421485
16 December 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1455543
10 March 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1104079
22 July 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1092171
11 March 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886274
27 February 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886378
15 March 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 867704
9 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1150894
25 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165771
23 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855503
23 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855505
14 March 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 858978
7 March 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855328
19 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150281
31 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840198
29 May 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 958576
28 May 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 958684
24 May 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 892904
15 May 1991
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 910152
27 April 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 900220
29 August 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036363
12 May 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037993
7 April 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199786
17 June 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1205062
11 May 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040506
5 May 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030809
20 October 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017043
12 June 1987
Hull Examination · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1316120
Deficiency record · 213
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 5 May 2025
Resolved
Provide copy of valid FCC Safety Radio Telephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
An adult life jacket must be provided for each person on the vessel. The vessel was missing 02.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
Each life jacket carried on an oceans and/or coastwise route. Missing lights on all required life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
The number of life jackets must be clearly marked to indicate quantity and size of life jackets are located in stowage container. Missing marking for 03 adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2024
Resolved
Each life buoy must be clearly legible block capital letters with the vessel name. The name of the vessel needs to be re-applied to the life buoy.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Vessel has completed bow pulpit modification. Structural drawings for bow pulpit have not yet been approved by MSC. Vessel has successfully completed SST 02APR2024 after bow pulpit modification was completed. Vessel shall restrict passenger access to bow pulpit until structural drawings are approved.
46 CFR 176.700 (b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2022
Resolved
Vsl needs to be able to retrieve person in the water in
adequate time frame. Provide evidence of a device that
will aid in retrieving person in the water during
simulated emergency conditions.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2022
Resolved
Life float pendants that secure the basket is
deteriorated. Replace line with suitable line that is
referenced in Sub Q 160.010.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2022
Resolved
Vsl on Oceans route and needs light on lifejackets. Current chemical lights are not recommended for cold water and the Sector Long Island Sound cold water time frame is Memorial Day-Nov 1st. If operator doesnt want to put correct lights onboard we can reduce the route to Limited Coastwise.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 12 October 2021
Resolved
Hydrostatic installation date not marked on EPIRB release unit. O/O needs to provide receipt and pictures of HRU verifying proper installation date is captured.
46CFR185.740(b)
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 October 2021
Resolved
Belt driven fire pump lacking belt guard; presenting hazard to operator in emergency use. Ensure running machinery is covered.
46CFR177.35-15
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
Dead end wiring in main cabin bilge and in port side of lazarette bilge. Remove unused wires/cover to ensure all are aware wires are not in use. Ensure watertight integrity is maintained through watertight bulkhead.
46CFR183.200
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
Missing 32 lights on lifejackets. Vessels on ocean going route require lifejacket lights.
46CFR180.75
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
Lifejacket stowage not clearly labeled. Require clearly legible letters and numbers on each container for lifejackets.
46CFR185.604(f)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has 141 out of 147 life jackets required (extended size). Provide 6 more extended size life jackets with lights to meet requirement. - 46 CFR 180.71
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 October 2020
Resolved
Perform a simplified stability test in the presence of a marine inspector pror to 27OCT2020. 46CFR178.310
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 28 October 2020
Resolved
Provide evidence of drug testing for all crewmembers employed onboard. 46 CFR16.210(a)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 October 2019
Resolved
Replace hydrostatic release for EPIRB 46 CFR 180.64
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2019
Resolved
Remove dead end wires above STBD main engine 46 CFR 183.05-50(b)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 October 2019
Resolved
Seal holes in coaming in aft section of accomadation space under door 46 CFR 178.360(d)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 October 2019
Resolved
Install cotter pin in steering linkage to rudder 46 CFR 177.110
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019
Resolved
Acquire spanner wrench (for fire hose) 46 CFR 181.310(d)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2019
Resolved
Seal lighting box on port side fantail 46 CFR 183.10-20(k)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 October 2019
Resolved
Tighten leaking packing on port side rudder post 446 CFR 177.110
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 26 September 2018
Resolved
Perform a simplified stability test in the presence of a USCG Marine Inspector no later than 30 Nov 2018.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2018
Resolved
Vessel is restricted to 100 total people on board, 96 of which may be passengers.
Owner does not intend to repair this deficiency. He is waiting on the results of the stability test in November to determine the total passenger count.
Construction/Loadline › Hull › Weld
Issued 29 September 2017
Resolved
Many weld seams on hull where coating failure has occured has evidence of electrolysis. Welds are wasted. Gouge and recap welds. 46 CFR 177.10-1(a)
Stability › Unintentional Flooding › General
Issued 26 September 2017
Resolved
One section of hard pipe on the bilge manifold was replaced with a rubber spool piece. Replace rubber spool with spool of pipe of similar metal material as the rest of the bilge system. 46 CFR 56.50(a)(1)
Electrical › Electric Generation Source (service) › Panelboard
Issued 5 June 2017
Resolved
Required amp meter for generator was non-functioning. Prove proper operation of amp meter required by 46 CFR 183.10-5(g)
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Provide nautical charts on baord vessel. 46 CFR 184.420(a).
Communications › Radio Communications › VHF Radiotelephone
Issued 5 June 2017
Resolved
Provide GPS input to VHF radio for DSC. 46CFR184.502
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017
Resolved
Replace expired Aspirin and Ammonia Inhalants. 46 CFR 160.041
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 April 2016
Resolved
Repair cracks in starboard side weld insert to satisfaction of Marine Inspector. As per OLD T 46 CFR 177.13-1. No sail issued.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2016
Resolved
Repair exposed wire in engine room. As per OLD T 46CFR183.05-10
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 20 April 2016
Resolved
Repair lagging on Port and Starboard exhaust to satisfaction of Marine Inspector. As per Old T 46CFR182.15-20
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 September 2015
Resolved
Repair cracked weld on port longitudinal attached to the stern IAW 46 CFR176.610
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 September 2015
Resolved
Prepare starboard cutlass bearing for inspection or replace IAW 46 CFR 176.610
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 6 August 2015
Resolved
Replace 1 weak link for 2 of the buayant apparatus'. 46CFR180.130(a)(1)
Lifesaving › Buoyant Apparatus › Lifeline
Issued 6 August 2015
Resolved
Replace all non-serviceable/weathered buoyant apparatus' lifeline with approved/serviceable type. 46CFR180.175(e)(1)
Lifesaving › Buoyant Apparatus › Serviceable
Issued 6 August 2015
Resolved
Repair cracks in buoyant apparatus'. 46CFR180.175(a)
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 6 August 2015
Resolved
Replace one broken float light for buoyant apparatus. 46CFR180.175(f)(4)
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 August 2015
Resolved
Replace weathered/non-serviceable life buoy lifeline. 46CFR180.70(c)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 August 2015
Resolved
Secure starboard main propulsion engine belt guard. 46CFR177.960
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 August 2015
Resolved
Vessel must have EPIRB installed. Restricted to no more than 3 NM from land. 46CFR180.64
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 6 August 2015
Resolved
Install fire extinguisher bracket for B-II fire extinguisher. 46CFR181.520
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 June 2014
Resolved
Ensure distribution panels are completely enclosed IAW 46 CFR 183.330(b).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 June 2014
Resolved
Vessel limited to daytime ops only until expired waterlight battery on ring buoy is replaced IAW 46 CFR 176.810(c)
Navigation › Piloting/Steering › Marine Charts
Issued 26 June 2014
Resolved
Provide an up-to-date chart IAW 46 CFR 184.420.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 June 2014
Resolved
Provide ammonia inhalants for first aid kit IAW 46 CFR 184.710
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 February 2010
Resolved
Provide updated items for first aid kit that have expired.
Lifesaving › Lifefloat › Netting
Issued 1 February 2010
Resolved
Repair/replace nets (4) in lifefloats.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 February 2010
Resolved
Replace batteries (3) on lifefloat water lights.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 February 2010
Resolved
Remove / cover dead light junctions on rail in front of pilot house.
Engineering › Bilge Water Management System › Piping
Issued 1 February 2010
Resolved
Make permanent erpair to bilge pipe in #2 void space.
Stability › Watertight Integrity › General
Issued 1 February 2010
Resolved
Repair hole in the deck in way of the port toilet.
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 1 February 2010
Resolved
Make peranent repairs to stbd main propulsion engine exhaust pipe.
Engineering › Bilge Water Management System › Piping
Issued 1 February 2010
Resolved
Install valve on spool piece for fire/bilge overboard connection.
Electrical › Electric Supply System (service) › Cable
Issued 1 February 2010
Resolved
Remove dead end cable under port main propulsion engine.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2010
Resolved
Install light cover (fwd, stbd) in accommadation space.
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2010
Resolved
Remove dead wires on deck on sides of pilot house.
Construction/Loadline › Penetrations › Weld
Issued 14 May 2009
Resolved
REPAIR DECK CONNECTION IWO STBD ENGINE ROOM HATCH AND POTABLE WATER TK FILL IN LAZARET.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 May 2009
Resolved
REPAIR/REPLACE BULKHEAD CONNECTION AND REPLACE HOSE ON GENERATOR EXHAUST PIPE IN THE LAZARET COMPARTMENT.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 May 2009
Resolved
INSTALL 30 X 30 MESH FLAME SCREENS ON ALL FUEL OIL TK VENTS.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 May 2009
Resolved
SERVICE FIRE EXTINGUISHER IN GALLEY AREA.
Engineering › Steering Gear System › Pin
Issued 14 May 2009
Resolved
REPLACE PIN IN STEERING ARM CONNECTION TO THE PORT RUDDER.
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2008
Resolved
PROVIDE UP TO DATE SAFETY RADIO CERTIFICATE.
Electrical › Electric Supply System (service) › Cable
Issued 12 May 2008
Resolved
PROPERLY SUPPORT ELECTRICAL CABLES IN MIDDLE COMPARTMENT.
Electrical › Electric Supply System (service) › Cable
Issued 12 May 2008
Resolved
MAKE PROPER ELECTRICAL CONNECTION IN CABLE FOR ENGINE ROOM LIGHTS.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 May 2007
Resolved
Properly mount fire extinguisher in accommodation space.
Navigation › Piloting/Steering › Gyro Compass
Issued 14 May 2007
Resolved
Repair/replace compass light.
Lifesaving › Lifefloat › Lifeline
Issued 14 May 2007
Resolved
Replace wasted lines on lifefloats as needed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2007
Resolved
Remove wire nuts throughout the vessel.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 May 2006
Resolved
Update all nautical publications. POC had last years editions. Gave them the website to down load coast pilot and light list.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2006
Resolved
Up date first aid kit. Gave them the required CG list of items that belong in kit.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 May 2006
Resolved
Provide seperation between child size and adult size life jackets. They had them in the same container without a seperation barrier.
Construction/Loadline › Penetrations › Gasket
Issued 9 May 2006
Resolved
Replace gaskets on all outside deck hatches or make watertight. Every deck hatch was leaking water into the bilges while dogged down except for the FWD void.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 May 2006
Resolved
Repair or remove lights in after steering that are full of water. The globes for the lights are half full of water, and if energized could cause damage. POC stated that they are disconnected and they will remove fixures.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 May 2006
Resolved
Prior to the carriage of passengers, provide a work vest and safety line for crew member during person OVBD drills.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 13 September 2005
Resolved
Replace all rotton gasket material on all deck hatches as needed.
Lifesaving › Buoyant Apparatus › Approval
Issued 14 February 2005
Resolved
Prior to the carriage of passengers, replace ring life buoy IAW 46CFR180.30-5.
Engineering › Bilge Water Management System › Not Installed
Issued 14 February 2005
Resolved
Provide a bilge high level alarm for AFT steering and #3 void IAW 46CFR182.530.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 February 2005
Resolved
Provide a visual light for engine room bilge high level alarm.
Documentation › Certificates/Documents › FCC SSL
Issued 14 February 2005
Resolved
Provide a copy of a FCC Marine Radio Operator Permit for [name withheld].
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 February 2005
Resolved
Update Emergency Instructions to match vessel layout.
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2005
Resolved
Repair electrical box behind bar.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 February 2005
Resolved
Provide proper light bulbs IAW manufacturer instruction or provide proper light cover for all lights throughout vessel/voids. Several light covers, in voids, have signs of over-heating and have melted through. They are using the long-lasting light bulbs, which may be to powerful for the covers.
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2005
Resolved
Remove all un-used wires throughout vessel as discussed.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 June 2004
Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Communications › Radio Communications › EPIRB
Issued 14 June 2004
Resolved
REPAIR/PEPLACE 406MHZ EPIRB PRIOR TO CARRIAGE OF PASSENGERS.
Engineering › Bilge Water Management System › Piping
Issued 14 June 2004
Resolved
REPAIR BILGE PIPING IN FOREPEAK AND CONDUCT OPERATIONAL TEST PRIOR TO CARRIGE OF PASSENGERS. LEGACY COMPONENT DESC: Piping
Electrical › Electric Supply System (service) › Cable
Issued 14 June 2004
Resolved
REMOVE DEAD END WIRING FROM ENGINE ROOM.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 June 2004
Resolved
REPLACE DROP NETTING IN UPPER 12 MAN LIFEFLOAT. LEGACY COMPONENT DESC: Netting
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 14 June 2004
Resolved
REMOVE EXCESSIVE ABSORBANT PADS FROM ENGINE ROOM BILGE PRIOR TO CARRIAGE OF PASSENGERS.
Documentation › Certificates/Documents › FCC SSL
Issued 14 June 2004
Resolved
RE-NEW FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2004
Resolved
REMOVE SLUDGE FROM STBD MAIN AND GENSET WIRING PRIOR TO CARRIAGE 0F PASSENGERS.
Engineering › Bilge Water Management System
Issued 20 October 2003
Resolved
Prove that the hose used in you fixed bilge system meets SAE J-1942 hose. LEGACY COMPONENT DESC: Bilge piping
Electrical › Electrical Distribution System (service)
Issued 17 March 2003
Resolved
RE-MOUNT OUTLET BOX BEHIND SINK. LEGACY COMPONENT DESC: Outlet Box
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 March 2003
Resolved
REPLACE RETROFLECTIVE MATERIAL ON LIFEJACKETS AS NEEDED. LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Buoyant Apparatus
Issued 17 March 2003
Resolved
REPLACE RETROFLECTIVE MATERIAL ON PORT BOTTOM LIFEFLOAT. LEGACY COMPONENT DESC: Retroflective Material
Engineering › Bilge Water Management System
Issued 17 March 2003
Resolved
PROPERLY WIRE AFT (SECONDARY) BILGE PUMP.
Engineering › Bilge Water Management System
Issued 17 March 2003
Resolved
INSTALL POSITIVE CLOSURE DEVICES ON SECONDARY BILGE PUMP HULL PENETRATIONS. LEGACY COMPONENT DESC: Valve
Engineering › Bilge Water Management System
Issued 17 March 2003
Resolved
REPAIR FWD BILGE SUCTION REACH ROD. LEGACY COMPONENT DESC: Valve
Electrical › Lighting (emergency)
Issued 17 March 2003
Resolved
REPLACE BULBS AND GLOBES ON 32V EMERGENCY LIGHTING. LEGACY COMPONENT DESC: Lighting Fixture
Construction/Loadline › Structures
Issued 17 March 2003
Resolved
INSTALL CAPTIVE DEVICE ON STBD ENGINE ROOM DECK HATCH. LEGACY COMPONENT DESC: Scuttle
Engineering › Bilge Water Management System
Issued 17 March 2003
Resolved
INSTALL VALVE HANDLE ON LAZARETTE BILGE SUCTION LINE AT MANIFOLD. LEGACY COMPONENT DESC: Valve
Communications › Radio Communications
Issued 17 March 2003
Resolved
UPDATED FCC SAFETY RADIOTELEPHONE CERTIFICATE. LEGACY COMPONENT DESC: FCC Safety Certificate
Navigation › Collision/Grounding Avoidance
Issued 15 August 2002
Resolved
REPAIR/REPLACE FWD MASTHEAD LIGHT AND STERN LIGHT PRIOR TO NIGHT OPERATION. LEGACY COMPONENT DESC: Navigation Lights
Lifesaving › Buoyant Apparatus
Issued 15 August 2002
Resolved
PROPERLY INSTALL LIFEFLOATS PRIOR TO CARRIAGE OF PASSENGERS.
Engineering › Bilge Water Management System
Issued 15 August 2002
Resolved
INSTALL HIGH LEVEL BILGE ALARM IN ENGINE ROOM PRIOR TO CARRIAGE OF PASSENGERS.
Electrical › Lighting (emergency)
Issued 15 August 2002
Resolved
REPAIR 32 VOLT EMERGENCY LIGHTING.
Electrical › Electrical Distribution System (service)
Issued 15 August 2002
Resolved
REPAIR CORRODED SWITCH IN 3RD VOID. LEGACY COMPONENT DESC: Outlet Box
Electrical › Electrical Distribution System (service)
Issued 15 August 2002
Resolved
ENSURE EACH BREAKER IN EACH DISTRIBUTION PANEL IS PROPERLY LABELED. LEGACY COMPONENT DESC: Distribution Panel Bus
Fire Fighting › Miscellaneous Items
Issued 15 August 2002
Resolved
INSTALL 30 X 30 MESH FLAME SCREENS IN STARBOARD FUEL VENT AND SEWAGE VENT. LEGACY COMPONENT DESC: Flame Screens
Construction/Loadline
Issued 14 November 2001
Resolved
MAKE PERMANENT REPAIRS TO DOUBLER PLATE OVER INSET IN STBD PORT ENGINE ROOMAND PAD WELDS IN WAY OF PORT FUEL TANK.
Lifesaving
Issued 7 May 2001
Resolved
REPLACE 406 MHZ EPIRB HYDROSTATIC RELEASE PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving
Issued 7 May 2001
Resolved
REPLACE DROP NET IN PORT TOP LIFEFLOAT.
Lifesaving
Issued 7 May 2001
Resolved
UPDATE 406 MHZ EPIRB REGISTRATION.
Lifesaving
Issued 7 May 2001
Resolved
ENSURE PROPER STENCILING OF LIFEFLOATS.
Navigation
Issued 7 May 2001
Resolved
REPLACE ANCHOR LIGHT WITH UL APPROVED ANCHOR LIGHT.
Electrical
Issued 7 May 2001
Resolved
REPAIR DEAD COVER ON BRIDGE DISTRIBUTION PANEL.
Electrical
Issued 7 May 2001
Resolved
INSTALL WET OUTLET COVER IN GALLEY.
Lifesaving
Issued 7 May 2001
Resolved
CONDUCT MAN OVERBOARD DRILL.
Electrical
Issued 6 March 2000
Resolved
INSTALL BLANK IN BRIDGE DISTRIBUTION PANEL.
Lifesaving
Issued 6 March 2000
Resolved
PROPERLY CONFIGURE LIFEFLOATS PRIOR TO CARRIAGE OF PASSENGERS.
Fire Fighting
Issued 6 March 2000
Resolved
CONDUCT ANNUAL SERVICING OF PORTABLE FIRE EXTINGUISHERS.
Documentation
Issued 6 March 2000
Resolved
PROVIDE FCC STATION LICENSE.
Unknown
Issued 6 March 2000
Resolved
INSTALL OVERBOARD DISCHARGE VALVE ON MSD. EITHER ONE OF 3 OPTIONS TO BE MET WHEN VESSEL OPERATING WITHIN 3 MILES OF LAND, (1) CLOSE VALVE AND REMOVE HANDLE, (2) PADLOCK VALVE CLOSED, (3) WIRE TIE CLOSED.
Electrical
Issued 6 March 2000
Resolved
INSTALL COVER ON AFT PILOT HOUSE ELECTRICAL OUTLET (WET LOCATION).
Lifesaving
Issued 6 March 2000
Resolved
REPLACE DETACHABLE HOOK ON LIFERING.
Lifesaving
Issued 6 March 2000
Resolved
PROPERLY STENCIL VESSEL NAME ON LIFERING.
Unknown
Issued 6 March 2000
Resolved
INSTALL PLACARD STATING NO MORE THAN 29 PASSENGERS ALLOWED ON UPPER DECK.
Documentation
Issued 14 December 1999
Resolved
RESOLVE DISCREPANCY BETWEEN STABILITY LETTER AND OPERATING DETAILS IN REGARDS TO USE OF UPPER DECK FOR CARRIAGE OF PASSENGERS. OWNER TO PROVIDE COMPARISON DETAILS OF GULF CRAFT HULL #305 (M/V [name withheld]) AND GULF CRAFT HULL #185 (M/V FLYING FISH II) TO PROVE SISTER SHIP STATUS.
Lifesaving
Issued 1 December 1999
Resolved
REPAIR OR REPLACE 22 PERSON LIFE FLOAT.
Lifesaving
Issued 1 December 1999
Resolved
REPAIR WORN DROP BASKET ON LIFE FLOAT SER #2F6948.
Documentation
Issued 1 December 1999
Resolved
RESOLVE APPARENT DISCREPANCY BETWEEN THE STABILITY LETTER INFORMATION AND THE OPERATING DETAILS AS PER COI WITH REGUARDS TO THE USE OF THE UPPER DECKFOR THE CARRIAGE OF PASSENGERS AND THE PRESENCE OF THE CANOPY OVER THE UPPER DECK. NO PASSENGERS ON UPPER DECK NOR RIG THE CANOPY UNTIL RESOLVED.
Electrical
Issued 8 March 1999
Resolved
FORE PEAK: INSTALL METAL CABLE SUPPORTS FOR CABLE ON PORT SIDE
Electrical
Issued 8 March 1999
Resolved
VOID #1, AFT OF FORE PEAK: REPLACE PLASTIC WIRE TIES WITH METAL STRAP FOR THE OVERHEAD LIGHT CABLES IN VOID #1, AFT OF FORE PEAK.
Engineering
Issued 8 March 1999
Resolved
REPLACE PVC PIPE ON DISCHARGE SIDE OF HEAT EXCHANGER TO EXHAUST PIPE WITH METAL, ALUM., BRASS/COPPER PIPE.
Engineering
Issued 8 March 1999
Resolved
WELD SUPPORT BRACKET FOR RAW WATER LINE ABOVE STBD ENGINE. LINE IS THE INBOARD 1" HOSE GOING INTO THE PORT EXHAUST
Electrical
Issued 8 March 1999
Resolved
MAIN POWER PANEL: REPLACE FREQ. GAUGE OR REMOVE AND INSTALL A BLANK COVER,AN OPERATIONAL GAUGE IS LOCATED ON THE BRIDGE.
Engineering
Issued 8 March 1999
Resolved
ENGINE ROOM: INSTALL A PLUG IN THE F/O FILTER LOCATED ON THE FWD BULKHEAD LEFT OF CENTER LINE. FILTER HAS NO PIPE/LINE CONNECTED TO IT, AFTER THE VALVE, OPEN TO THE ENGINE ROOM
Accommodation/Occupational Safety
Issued 8 March 1999
Resolved
LAZ: INSTALL DOUBLE CLAMPS TO MSD DISCHARGE HOSE LOCATED ON BOTTOM OF TANK, AND REPLACE 15" SECTION LOCATED ON FWD BULKHEAD STBD SIDE, AND DOUBLECLAMP.
Lifesaving
Issued 8 March 1999
Resolved
STENCIL "NUMBER AND SIZE OF LIFE JACKET" ON PFD STOWAGE LOCKERS.
Accommodation/Occupational Safety
Issued 8 March 1999
Resolved
PROPERLY INSTALL CABLE INTO OUTLET BOX LOCATED ON THE STBD SIDE BULKHEAD OFTHE MAIN ACCOMS SPACE IWO GALLEY, UNDER SHELF BY ENTRANCE INTO SINK AREA
Electrical
Issued 8 March 1999
Resolved
REMOVE OLD INTERCOM SYSTEM WIRES LOCATED IN MAIN ACCOMS BY SINK
Navigation
Issued 8 March 1999
Resolved
PROVIDE CHARTS, 46CFR SUBPART T, RULES OF THE ROAD, COAST PILOT, NOTICE TO MARINERS, LIGHT LIST, CURRENT TABLES, TIDE TABLES AS PER 46CFR 184.420
Lifesaving
Issued 8 March 1999
Resolved
PROVIDE LOG BOOK FOR EMERG. DRILLS. NO DRILLS HAVE BEEN LOGGED SINCE FEB 98.
Navigation
Issued 8 March 1999
Resolved
REPLACE CRACKED ANCHOR LIGHT GLOBE ON MAST.
Electrical
Issued 8 March 1999
Resolved
INSTALL A BLANK IN THE 12V POWER PANEL ON BRIDGE
Electrical
Issued 8 March 1999
Resolved
PROVIDE A FIRST AID KIT, CURRENT KIT IS OUTDATED AND MISSING SEVERAL ITEMS
Lifesaving
Issued 8 March 1999
Resolved
PROPERLY LABEL ALL 3 BOUYANT APPARATUS TOP AND BOTTOM WITH VESSEL NAME AND CAPACITY. STOW ALL SEA PAINTERS NEATLY. CURRENTLY SEA PAINTERS ARE WRAPEDAROUND ANTENNAS
Lifesaving
Issued 8 March 1999
Resolved
PROPERLY LABEL RING BOUY, BOTH SIDES, AND INSTALL TYPE II RETRO REFELCTIVE TAPE TO BOTH SIDES
Lifesaving
Issued 8 March 1999
Resolved
PRIVIDE 6 ADULT LIFE PRESERVERS. UNTIL THIS REQUIREMENT IS CLEARED THE VESSEL MAY CARRY TOTAL NUMBER OF PERSONS ON OCEANS ROUTE: 86; AND ON LIMITED COASTWISE ROUTE 143.
Engineering
Issued 8 March 1999
Resolved
LABEL DIRECTION FOR CLOSING FUEL SHUT OFFS VALVES.
Electrical
Issued 8 March 1999
Resolved
REPLACE MISSING LIGHT GLOBE IN MEN'S HEAD.
Deck/Cargo
Issued 8 March 1999
Resolved
REPAIR HATCH COVERS IN MAIN ACCOMS. MISSING BOLTS ON HINGES. TOTAL OF 2 HATCHES.
Lifesaving
Issued 8 March 1999
Resolved
PROPERLY SECURE LIGHT TO RING BOUY. INSTALL A 3' LINE WITH A CLASP. CURRENTLY LIGHT IS FASTEN TO ONE END OF THE LINE (60') AND THE RING BOUY TOTHE OTHER.
Fire Fighting
Issued 8 March 1999
Resolved
PROVIDE PROOF OF SERVICE FOR ALL PORTABLE FIRE EXTINGUISHERS. EXP 02/99. ONE BII GAUGE READ DISCHARGE (ARROW OUT OF THE GREEN ZONE). _x001C_ _x001C_ ISSUED NO SAIL
Construction/Loadline
Issued 8 March 1999
Resolved
BILGE PIPING: REMOVE ALL RUBBER HOSES FROM BILGE PIPE SYSTEM AND HARD PIPESYSTEM MAY HAVE A SMALL SECTION TO CONNECT THE STRAINER TO THE MAIN PIPE
Electrical
Issued 8 March 1999
Resolved
ENGINE ROOM: REMOVE 1" PVC PIPE FROM ENGINE ROOM, AFT STBD SIDE FROM VALVEAND PLUG/CAP VALVE. LINE RUNS BEHIND GENERATOR AND IS OPEN, NOT CONNECTED TO ANYTHING
Construction/Loadline
Issued 8 March 1999
Resolved
VOID #2 AFT OF FOREPEAK: REPLACE MISSSING CONDUIT SUPPORT ON PORT SIDE VOID#2 AFT OF FORE PEAK.
Documentation
Issued 13 March 1998
Resolved
PROVIDE PROOF OF CURRENT FCC SAFETY CERTIFICATE (VSL HAS APPLICATION AND CANCELLED CHECK FOR FEE, AND HAS ALREADY COMPLETED FCC INSPECTION - JUST NEEDS UPDATED HARD-COPY CERTIFICATE
Lifesaving
Issued 13 March 1998
Resolved
PROVIDE 3 CURRENT ORANGE DISTRESS SIGNALS
Unknown
Issued 13 March 1998
Resolved
LABEL MAXIMUM CAPACITY OF UPPER DECK
Fire Fighting
Issued 13 March 1998
Resolved
REPAIR/REINSTALL LEAKY FIRE PUMP SEAL.
Electrical
Issued 13 March 1998
Resolved
REMOVE/CRIMP DEAD-ENDED WIRING UNDER BRIDGE CONSUL
Engineering
Issued 13 March 1998
Resolved
DOUBLE NUT/COTTER PIN/NILOCK ALL THROTTLE/CLUTCH LINKEAGES - SSDG & MDE'S
Electrical
Issued 13 March 1998
Resolved
REMOVE/CRIMP DEAD-ENDED WIRING OVER SWITCHBOARD IN ENGINE ROOM
Construction/Loadline
Issued 13 March 1998
Resolved
CAP OFF/REMOVE UBUSED POTABLE WATER LINE - LAZARETTE.
Fire Fighting
Issued 13 March 1998
Resolved
INSTALL MACHINERY GUARD FOR FIRE PUMP
Documentation
Issued 13 March 1998
Resolved
PROVIDE DECK LOG - LOG QUARTERLY DRILLS
Lifesaving
Issued 13 March 1998
Resolved
INSTALL PFD STOWAGE LABELS
Lifesaving
Issued 13 March 1998
Resolved
INSTALL UV RESISTANT LANYARDS FOR BA LIGHTS
Construction/Loadline
Issued 13 March 1998
Resolved
REMOVE UNUSED SODA SYSTEM O MIDSHIP STORAGE COMPT.
Electrical
Issued 13 March 1998
Resolved
SECURE ELECTRICAL CABLES TO OVHD/BLKHD W/ METALLIC CLAMPS AT APPROX. 24" INTERVALS
Construction/Loadline
Issued 13 March 1998
Resolved
LABEL BILGE MANIFOLD
Electrical
Issued 13 March 1998
Resolved
SECURE ELECTRIC CABLE TO OVHD - ENG ROOM
Construction/Loadline
Issued 16 December 1997
Resolved
RECONFIGURE UPPER DECK RAIL IAW 46 CFR 177.900 FOR VESSELS ENGAGED IN EXCURSION TRIPS.
Engineering
Issued 16 December 1997
Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS.
Lifesaving
Issued 11 March 1996
Resolved
PROVIDE 3 ADDITIONAL ORANGE SMOKE FLARES AND 6 RED FLARES.
Lifesaving
Issued 11 March 1996
Resolved
PROVIDE 4 ADDITIONAL ADULT LIFE PRESERVERS. WHEN VESSEL IS ON LAKE, BAYS AND SOUNDS VESSEL IS LIMITED TO 146 PASSENGERS.
Unknown
Issued 11 March 1996
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH DRUG PROGRAM REQUIREMENTS.
Construction/Loadline
Issued 27 February 1996
Resolved
REWELD STBD MDE FORWARD OUTBOARD MOUNT.
Construction/Loadline
Issued 27 February 1996
Resolved
REWELD PORT MDE FORWARD OUTBOARD MOUNT.
Construction/Loadline
Issued 27 February 1996
Resolved
REWELD 4TH SIDELONG ATTACHED TO THE COLLISION BULKHEAD STBD SIDE IN THE VOID SPACE.
Navigation
Issued 23 March 1994
Resolved
PROVIDE TIDE CURRENT TABLES.
Navigation
Issued 7 March 1994
Resolved
PROVIDE TIDE/ CURRENT TABLES.
Unknown
Issued 7 March 1994
Resolved
PROVIDE PROOF OF CHEMICAL TESTING PROGRAM.
Lifesaving
Issued 31 March 1993
Resolved
PROVIDE (PFD) LIFE VEST INSTRUCTIONS FOR TYPE ON BOARD.
Construction/Loadline
Issued 31 March 1993
Resolved
STENCIL BILGE MANIFOLD VALVES.
Fire Fighting
Issued 31 March 1993
Resolved
PROVIDE ONE BILGE/FIRE HAND PUMP.
Navigation
Issued 31 March 1993
Resolved
PROVE PROPER OPERATION OF MAGNETIC COMPASS LIGHT.
Construction/Loadline
Issued 31 March 1993
Resolved
PLUG HOLES IN ALL WATERTIGHT BULKHEADS WHERE OLD HYDRAULIC LINE FOR ANCHOR WINCH WAS REMOVED.
Lifesaving
Issued 31 March 1993
Resolved
REPAIR 22 MAN LIFE FLOAT OR PROVIDE A SUITABLE CG APPROVED (BA) BUOYANT APPARATUS FOR 22 MAN. TOTAL PERSONS ALLOWED TO BE CARRIED REDUCED TO 92 TILL THIS REQUIREMENT IS CLEARED.
Navigation
Issued 31 March 1993
Resolved
PROVIDE UP TO DATE CHARTS FOR OPERATING AREA, LIGHT LIST AND COAST PILOT.
Lifesaving
Issued 31 March 1993
Resolved
PROVIDE AND STENCIL SEPARATE CHILD LIVE VEST STORAGE.
Navigation
Issued 29 May 1992
Resolved
PROVIDE AN UPDATED COPY OF INLAND RULES OF THE ROAD._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 29 May 1992
Resolved
PROVIDE A POSTED COPY OF WASTE MANAGEMENT PLAN.
Navigation
Issued 24 May 1991
Resolved
PROVIDE THE MOST RECENT EDITION OF THE FOLLOWING CHARTS,#12211,#12318,#_x001C_ 12323,AND #12214,PRESENT EDITIONS ARE OUTDATED.
Navigation
Issued 24 May 1991
Resolved
PROVIDE THE MOST RECENT EDITION OF THE LIGHT LIST VOLUME 1. PRESENT COPY_x001C_ ONBOARD DATED 1987.
Documentation
Issued 27 April 1990
Resolved
POST STABILITY LETTER
Accommodation/Occupational Safety
Issued 27 April 1990
Resolved
DEMONSTRATE OPERATION OF WATER TO THE HEADS. DUE PRIOR TO CARRYING PASS.
Accommodation/Occupational Safety
Issued 27 April 1990
Resolved
REMOVE HOT WATER HEATER FROM THE VESSEL OR DEMONSTRATE OPERATION OF HOT WATER HEATER.
Lifesaving
Issued 27 April 1990
Resolved
PROVIDE LIGHTS ON ALL PFD'S PRIOR TO SAILING OCEANS.
Electrical
Issued 27 April 1990
Resolved
PROPERLY WIRE THE GALLEY RECEPTACLES WITH APPROVED CABLE.
Navigation
Issued 27 April 1990
Resolved
DEMONSTRATE THE OPERATION OF THE EPIRB. MUST BE COMPLETED PRIOR TO SAILING OCEANS.
Electrical
Issued 12 May 1989
Resolved
REMOVE WIRE NUTS AND MOUNT SPLICE IN A JUNCTION BOX IN THE FWD LIGHT CIRCUIT FOR THE 3RD COMPARTMENT. ORIGINAL COMPLIANCE DATE IS 26 MAY 89.
Navigation
Issued 12 May 1989
Resolved
DEMONSTRATE OPERATION OF SSB RADIO PRIOR TO SAILING ON AN OCEANS ROUTE. ORIGINAL COMPLIANCE DATE IS 26 MAY 89.
Unknown
Issued 11 May 1988
Resolved
POST COI AND FCC CERTIFICATES IN PILOT HOUSE.
Lifesaving
Issued 11 May 1988
Resolved
PROVIDE REQUIRED SIGNAL DEVICES.
Electrical
Issued 11 May 1988
Resolved
IN PILOT HOUSE, REMOVE UNUSED WIRING AND BLANK OFF OPEN AND UNUSED CIRCUIT BREAKER OPENINGS.
Unknown
Issued 11 May 1988
Resolved
PROPERLY MARK EPIRB, LIFE FLOATS, RING BUOY, CHILD'S LIFE JACKET STORAGE CONTAINER, CIRCUIT BREAKERS IN DISTRIBUTION PANELS.
Lifesaving
Issued 12 June 1987
Resolved
PROVIDE ONE ADDITIONAL CHILD'S LIFE PRESERVER AND WATER LIGHT FOR A TOTAL OF 16 CHILD'S LIFE PRESERVERS. VESSEL IS RESTRICTED TO CARRYING 15 CHILDREN UNTIL COMPLETED.
Casualty record · 1
14 October 2004Routine · role: Involved in a Marine Casualty · 1 dead · activity 2295037
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
FLYING FISH II (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.