Records from 2004 to 2026. Most recent: inspection, 20 March 2026.
Inspection history · 24
20 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327239
5 June 2025
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8153168
5 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8128781
26 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7897663
8 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7860767
8 February 2024
Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7862862
5 June 2023
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7704022
17 April 2023
Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7670260
6 February 2023
Annual Inspection
Physical examination · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7632701
1 December 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7602142
21 April 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7449845
16 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7367311
12 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7331655
22 January 2021
Construction Oversight · Deficiency Check · Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7128861
28 October 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7085655
6 July 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6998718
4 December 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6867438
16 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6835025
8 April 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6663036
17 August 2018
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6514690
20 March 2018
Deficiency Check · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6390897
26 September 2017
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6275095
5 June 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6160370
20 April 2016
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5858241
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 5 May 2025
Resolved
Provide copy of valid FCC Safety Radio Telephony Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 30 May 2025
Resolution: Recieved email of valid FCC safety radio cert.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
An adult life jacket must be provided for each person on the vessel. The vessel was missing 02.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 7 May 2024
Resolution: Vessel has total amount of life jackets onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
Each life jacket carried on an oceans and/or coastwise route. Missing lights on all required life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 7 May 2024
Resolution: All lifejackets have required lights attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
The number of life jackets must be clearly marked to indicate quantity and size of life jackets are located in stowage container. Missing marking for 03 adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 7 May 2024
Resolution: Stowage containers are clearly marked with amount.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2024
Resolved
Each life buoy must be clearly legible block capital letters with the vessel name. The name of the vessel needs to be re-applied to the life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 7 May 2024
Resolution: Life buoy has been re labeled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Vessel has completed bow pulpit modification. Structural drawings for bow pulpit have not yet been approved by MSC. Vessel has successfully completed SST 02APR2024 after bow pulpit modification was completed. Vessel shall restrict passenger access to bow pulpit until structural drawings are approved.
46 CFR 176.700 (b)
Action required: 705 - Other - as specified
Due 13 May 2024
Resolved 8 May 2024
Resolution: MSC has approved structural drawings for modification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2022
Resolved
Vsl needs to be able to retrieve person in the water in
adequate time frame. Provide evidence of a device that
will aid in retrieving person in the water during
simulated emergency conditions.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2022
Resolved
Life float pendants that secure the basket is
deteriorated. Replace line with suitable line that is
referenced in Sub Q 160.010.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2022
Resolved
Vsl on Oceans route and needs light on lifejackets. Current chemical lights are not recommended for cold water and the Sector Long Island Sound cold water time frame is Memorial Day-Nov 1st. If operator doesnt want to put correct lights onboard we can reduce the route to Limited Coastwise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 22 June 2022
Resolution: proper lights provided
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 12 October 2021
Resolved
Hydrostatic installation date not marked on EPIRB release unit. O/O needs to provide receipt and pictures of HRU verifying proper installation date is captured.
46CFR185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2021
Resolved 14 October 2021
Resolution: Owner provided proof of receipt and marked EPIRD accordingly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 October 2021
Resolved
Belt driven fire pump lacking belt guard; presenting hazard to operator in emergency use. Ensure running machinery is covered.
46CFR177.35-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2021
Resolved 27 October 2021
Resolution: O/O manufactured a cover for belt.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
Dead end wiring in main cabin bilge and in port side of lazarette bilge. Remove unused wires/cover to ensure all are aware wires are not in use. Ensure watertight integrity is maintained through watertight bulkhead.
46CFR183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2021
Resolved 14 October 2021
Resolution: O/O provided picture of removed dead end wire from compartment 3.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
Missing 32 lights on lifejackets. Vessels on ocean going route require lifejacket lights.
46CFR180.75
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2021
Resolved 14 October 2021
Resolution: O/O provided evidence of new waterlights for all 141 extended size life jackets and 12 child PFDs on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
Lifejacket stowage not clearly labeled. Require clearly legible letters and numbers on each container for lifejackets.
46CFR185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2021
Resolved 14 October 2021
Resolution: O/O provided picture of new life jacket labeling and number clearly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has 141 out of 147 life jackets required (extended size). Provide 6 more extended size life jackets with lights to meet requirement. - 46 CFR 180.71
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2021
Resolved 18 October 2021
Resolution: O/O provided receipt showing proof of purchase of additional lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 October 2020
Resolved
Perform a simplified stability test in the presence of a marine inspector pror to 27OCT2020. 46CFR178.310
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2020
Resolved 6 May 2021
Resolution: performed SST and final stability letter signed on this date and uploaded to file.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 28 October 2020
Resolved
Provide evidence of drug testing for all crewmembers employed onboard. 46 CFR16.210(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2020
Resolved 3 June 2021
Resolution: Owner submitted evidence for drug testing of all employees.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 October 2019
Resolved
Replace hydrostatic release for EPIRB 46 CFR 180.64
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing new hydro
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2019
Resolved
Remove dead end wires above STBD main engine 46 CFR 183.05-50(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing wires removed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 October 2019
Resolved
Seal holes in coaming in aft section of accomadation space under door 46 CFR 178.360(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing holes welded over
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 October 2019
Resolved
Install cotter pin in steering linkage to rudder 46 CFR 177.110
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing 'key' type pins installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019
Resolved
Acquire spanner wrench (for fire hose) 46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing new wrench
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2019
Resolved
Seal lighting box on port side fantail 46 CFR 183.10-20(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing pvc plug installed
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 October 2019
Resolved
Tighten leaking packing on port side rudder post 446 CFR 177.110
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 18 October 2019
Resolution: Owner provided photos showing rudder post was tightened
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 26 September 2018
Resolved
Perform a simplified stability test in the presence of a USCG Marine Inspector no later than 30 Nov 2018.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 28 October 2020
Resolution: Re-issued deficiency for same requirement with a 30 day requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2018
Resolved
Vessel is restricted to 100 total people on board, 96 of which may be passengers.
Owner does not intend to repair this deficiency. He is waiting on the results of the stability test in November to determine the total passenger count.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2018
Resolved 28 October 2020
Resolution: Vessel had all PFDs and primary lifesaving required to carry its original passenger/crew count of 103.
Construction/Loadline › Hull › Weld
Issued 29 September 2017
Resolved
Many weld seams on hull where coating failure has occured has evidence of electrolysis. Welds are wasted. Gouge and recap welds. 46 CFR 177.10-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 December 2017
Stability › Unintentional Flooding › General
Issued 26 September 2017
Resolved
One section of hard pipe on the bilge manifold was replaced with a rubber spool piece. Replace rubber spool with spool of pipe of similar metal material as the rest of the bilge system. 46 CFR 56.50(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 December 2017
Resolution: Bilge pipe repaired utilizing similar metallic material as bilge system.
Electrical › Electric Generation Source (service) › Panelboard
Issued 5 June 2017
Resolved
Required amp meter for generator was non-functioning. Prove proper operation of amp meter required by 46 CFR 183.10-5(g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 9 August 2017
Resolution: Verified AMP Meter is working properly.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Provide nautical charts on baord vessel. 46 CFR 184.420(a).
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 9 August 2017
Resolution: New navigation charts provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 June 2017
Resolved
Provide GPS input to VHF radio for DSC. 46CFR184.502
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 9 August 2017
Resolution: Verified GPS input to VHF radio.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017
Resolved
Replace expired Aspirin and Ammonia Inhalants. 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 9 August 2017
Resolution: Verified operator replaced expired aspirin and ammonia inhalants.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 April 2016
Resolved
Repair cracks in starboard side weld insert to satisfaction of Marine Inspector. As per OLD T 46 CFR 177.13-1. No sail issued.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2016
Resolved 5 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2016
Resolved
Repair exposed wire in engine room. As per OLD T 46CFR183.05-10
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 25 April 2016
Resolution: Exposed wire in engine room repaired.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 20 April 2016
Resolved
Repair lagging on Port and Starboard exhaust to satisfaction of Marine Inspector. As per Old T 46CFR182.15-20
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 5 May 2016