MAURY USCG vessel records
← All vessels

ZOURVA

ZOURVA is a 2014 tank ship. The Coast Guard has recorded 8 inspections since 2017, most recently in August 2025, along with 2 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 27 August 2025.

Built
2014
Last inspected
27 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 August 2025
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9679593
9HA3434
1290137
Flag
MALTA
Maury page id
psix-1290137

Documentation record

Tonnage as PSIX records it108429 - Convention (Subpart B), Net Ton
318514 - Dead Weight, Metric Ton
366534 - Displacement, Metric Ton
164756 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

27 August 2025 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8215025
17 June 2024 COC-TVE Renew · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7932153
26 January 2023 Deficiency Check · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7624452
28 April 2021 COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7181337
22 February 2020 COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6908325
13 February 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6908362
22 July 2018 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6481511
3 February 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6074296

Deficiency record · 2

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 January 2023 Resolved
Where cables are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areass, special precautions against such risks shall be taken to the satisfaction of the administration. PSCO observed several improperly installed temperature sensors in the cargo pump room, as well as two COP Junction boxes missing their grounding straps and an improperly installed o2 sensor for the vessels fixed gas detection system all within the cargo pump room. 74 SOLAS 20 Ch. II-1 / Reg. 45.5.4
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2023
Resolved 27 January 2023
Resolution: Received Class Report attesting to the repairs of the cable glands. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Cargo pumproom
Issued 26 January 2023 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards shall be ensured. PSCO observed 01 explosion proof light fixture in the cargo pump room missing one of six clasps. 74 SOLAS 20 Ch. II-1 / Reg. 40.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 January 2023
Resolved 26 January 2023

Ownership record