MAURY USCG vessel records Sign in
← All vessels

PLEASURE MERCHANT

PLEASURE MERCHANT is a 1974 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1993, most recently in September 2008, along with 49 deficiencies — 1 with no resolution recorded —.

Records from 1993 to 2008. Most recent: inspection, 11 September 2008.

Built
1974
Last inspected
11 September 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYT2533
129080
Flag
UNITED STATES
366703880 (licence lapsed)
Maury page id
psix-129080

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 16 calendar years (1993–2008)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCV5612MMSI 366703880 · expired · compulsorily equipped · granted 29 November 1995, cancelled 4 February 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

11 September 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3330983
13 September 2007 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3057503
1 May 2007 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2920535
14 July 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2716107
4 May 2005 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2384482
19 April 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2347679
12 April 2004 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2042169
16 July 2003 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1922894
24 June 2003 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1922803
10 June 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1635994
27 June 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362426
7 June 2001 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362425
26 April 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441712
13 September 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 784073
24 June 1999 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1099359
29 April 1999 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 794260
13 October 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 806742
23 July 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 797134
21 May 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1126269
2 September 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 786193
30 April 1997 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1402460
11 April 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1368223
8 September 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 97832
8 September 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 214754
8 September 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 214908
15 May 1996 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1419609
22 April 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1081655
30 January 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1192650
7 June 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1449837
4 May 1994 Plan Review "T" Boat · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173816
15 April 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1174035
25 October 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 660828

Deficiency record · 49

Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 11 September 2008 No resolution recorded
Vessel currently has a non UL approved fire suppression system. The heat sensor is not UL listed and/or approved. Vessel owner will be given until next season to install a type approved fixed fire fighting system that is in line w/ current NFPA and USCG standards.
Action required: 705 - Other - as specified
Due 11 September 2009 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 September 2007 Resolved
Levin Harrisson failed to make vessel available for inspection within anniversay date 04May2007.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 17 April 2008
Resolution: Deficiency has been corrected after a consultation w/ Levin Harrisson about the scheduling conflict from last annual exam. The marine inspector had to re-schedule exam and therefor Levin passed his COI due date, but Levin was given guidance.
Construction/Loadline › Hull › Transverse Frame
Issued 1 May 2007 Resolved
Replace wasted backing for steering hydraulic piping junction box fwd of steering ram along transverse frame.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 5 July 2007
Resolution: Backing replaced and verified by O/Op.
Construction/Loadline › Hull › Keel
Issued 1 May 2007 Resolved
Provide repair proposal for wasted section of keel fwd of steering ram.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2007
Resolved 5 July 2007
Resolution: Repair proposal submitted and excepted. Repairs completed and verified with O/Op.
Electrical › Electric Supply System (service) › Cable
Issued 14 July 2006 Resolved
Remove wire nuts and provide a soderless crimp style connection for all wires using the wire nuts.
Due 21 July 2006
Resolved 26 July 2006
Resolution: Nuts removed and proper connections installed.
Electrical › Electric Supply System (service) › Cable
Issued 14 July 2006 Resolved
Replace chaffed and damaged starter cable on port engine.
Due 21 July 2006
Resolved 26 July 2006
Resolution: Chaffed cable replaced.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 14 July 2006 Resolved
Reconnect ground conductor for the port fuel tank.
Due 21 July 2006
Resolved 26 July 2006
Resolution: Ground reconnected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 July 2006 Resolved
Make repairs to high water alarm.
Due 21 July 2006
Resolved 26 July 2006
Resolution: repaired.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 14 July 2006 Resolved
Replace faded retro tape on BA.
Due 21 July 2006
Resolved 26 July 2006
Resolution: New tape installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 July 2006 Resolved
Provide current Inland Nav rules.
Due 21 July 2006
Resolved 26 July 2006
Resolution: Provided.
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Repair leak from stbd and port longitudinal planks just above chine log
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2003
Construction/Loadline › Hull
Issued 16 July 2003 Resolved
Repair leak from butt of longitudinal plank on stbd side just aft of engine LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2003
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Repair leak from shaft log on stbd side
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2003
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Repair leak from port rudder flange
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2003
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Examine all fastenings for tightness.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2003
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Examine all seams and recaulk as necessary
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2003
Construction/Loadline › Structures › Deck Plating
Issued 24 June 2003 Resolved
Renew port & stbd stanchions for deck beams outboard of shaft log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2003
Construction/Loadline › Structures › Deck Plating
Issued 24 June 2003 Resolved
Renew stbd deck beam outboard of engine
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2003
Fire Fighting
Issued 24 June 1999 Resolved
ENSURE ENGINE SPACE BULKHEADS ARE COMPLETED AND PROVIDE MEANS TO SECURE VENTS.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Documentation
Issued 24 June 1999 Resolved
PROVIDE FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Engineering
Issued 24 June 1999 Resolved
ENSURE EMERGENCY FUEL SHUTOFF VALVES OPERATE PROPERLY.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 24 June 1999 Resolved
MAKE FIXED FIREFIGHTING CO2 BOTTLE PERMANENT INSTALLATION.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Lifesaving
Issued 24 June 1999 Resolved
REPLACE BUOYANT APPARATUS GRABLINES, PENDANTS AND SEAPAINTER.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Accommodation/Occupational Safety
Issued 24 June 1999 Resolved
ENSURE HANDRAIL IS CONTINUOUS AT STERN.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
PROVIDE VISUAL AND AUDIBLE INDICATOR FOR HIGH LEVEL BILGE ALARM.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 29 April 1999 Resolved
PROVIDE FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 21 May 1998 Resolved
DOUBLE HOSE CLAMP BILGE PUMP AND SANITARY HOSES.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Engineering
Issued 21 May 1998 Resolved
REPAIR WASTED EMER FUEL SHUT OFF VALVE HANDLES.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 May 1998 Resolved
PROVIDE EYE WASH SOLUTION FOR FIRST AID KIT.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 21 May 1998 Resolved
PROVIDE CURRENT FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Engineering
Issued 30 April 1997 Resolved
Replace hoses at keel/oil cooler both MDE's prior to carrying passengers.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Engineering
Issued 30 April 1997 Resolved
Repair leak to port MDE jabsco pump.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 30 April 1997 Resolved
Caulk as necessary at chine, port and starboard sides, prior to carrying passengers.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Engineering
Issued 30 April 1997 Resolved
Provide sensors for exhaust coolant flow.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 30 April 1997 Resolved
Repair forward port engine mount on port MDE prior to carrying passengers.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Navigation
Issued 30 April 1997 Resolved
Repair compass light.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Lifesaving
Issued 30 April 1997 Resolved
Provide and post emergency broadcast placard.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Lifesaving
Issued 30 April 1997 Resolved
Provide properly marked watertight box for VDS.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Lifesaving
Issued 30 April 1997 Resolved
Replace pendants on buoyant apparatus.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Lifesaving
Issued 30 April 1997 Resolved
Conduct satisfactory man overboard drill in the presence of a marine inspector.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 30 April 1997 Resolved
Attach grounding strap to fuel fill pipe prior to carrying passengers.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 30 April 1997 Resolved
Address as necessary rot in plank port quarter.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Documentation
Issued 30 April 1997 Resolved
Provide proof of current certificate of documentation.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Navigation
Issued 30 April 1997 Resolved
Provide current tide tables.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Documentation
Issued 30 April 1997 Resolved
Provide copy of subchapter T regulations.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Lifesaving
Issued 30 April 1997 Resolved
Provide logbook with proper entries.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Lifesaving
Issued 30 April 1997 Resolved
Provide proper first aid kit.
Condition: Unknown
Due 14 May 1997
Resolved 27 May 1997
Documentation
Issued 7 June 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Construction/Loadline
Issued 7 June 1995 Resolved
PORTABLE HAND BILGE/FIRE PUMP MISSING. REPLACE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995

Ownership record