MAURY USCG vessel records
← All vessels

HL GLADSTONE

HL GLADSTONE is a 2011 freight ship. The Coast Guard has recorded 5 inspections since 2020, most recently in June 2024, along with 3 deficiencies.

Records from 2020 to 2024. Most recent: inspection, 14 June 2024.

Built
2011
Last inspected
14 June 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9581174
1291278
Flag
PANAMA
Maury page id
psix-1291278

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2020–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it93872 - Convention (Subpart B), Gross Ton
179850 - Dead Weight, Ton
205791 - Displacement, Ton
59292 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

14 June 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7934816
9 April 2024 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7885571
25 March 2024 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7884464
25 July 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7515812
12 October 2020 PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7075644

Deficiency record · 3

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024 Resolved
The safety of passengers, crew and ship from electrical hazards will be ensured. PSCO overserved exposed electrical wiring on the excess steam dumping control box for the cascade tank. 74SOLAS(09)II-1/40.1.3 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 June 2024
Resolution: Received Survey Statement from KR attesting to rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024 Resolved
A fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. PSCO observed the hydraulic level below the required oil quantity for the steering gear storage tank. 74SOLAS(09)II-1/29.12.3 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 June 2024
Resolution: Received Survey Statement from KR attesting to rectification.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 July 2022 Resolved
Fire extinguishing appliances shall be readily available. PSCO observed that all five sprinkler heads in the paint locker were covered with a five gallon bucket. 74 SOLAS (20)/II-2/10.1.1.2 17c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 July 2022
Resolved 25 July 2022
Resolution: PSCO witnessed the removal of buckets on sprinkler heads.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.