COLUMBIANA

COLUMBIANA is a 2014 towing vessel. The Coast Guard has recorded 17 inspections since 2015, most recently in June 2026, along with 19 deficiencies.

Records from 2015 to 2026. Most recent: inspection, 24 June 2026.

Built
2014
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 June 2026
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2015–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7311
1291868
Flag
UNITED STATES
Maury page id
psix-1291868

Documentation record

Registered dimensions (L × B × D)55.0 ft × 18.0 ft × 7.0 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTELL CITY BOAT WORKS INC · TELL CITY · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Net Ton
46 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

24 June 2026 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8347230
1 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8109097
25 April 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7900764
19 July 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7745900
4 May 2023 Administrative Inspection · Internal Structural Exam · Damage Survey · Drydock Exam · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7680613
11 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7448642
28 October 2021 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7355771
13 May 2021 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7188469
23 March 2021 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7168761
29 July 2020 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7018057
3 October 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6827738
13 March 2019 Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6641936
4 May 2018 Administration · Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6417865
29 March 2017 Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6114400
29 March 2016 Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5843675
28 January 2016 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5805360
27 March 2015 Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5070110

Deficiency record · 19

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 June 2026 Resolved
Fire-detection systems. Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. The fire detection panel was found to be inoperable. Repair or install a fire detection system in accordance with 46 CFR 142.330. Per your request the vessel may operate with an additional trained crew member to assume a fire watch in the engine room at all times while the vessel is operating. The additional crew member shall be equipped with a radio in case of an emergency. An alternate crew shall be provided when the vessel is away from the dock for a period exceeding twelve (12) hours in any twenty-four (24) hour period. The vessel may operate under these terms until 01 JULY 2026 or until the fire detection panel is back restored to full operational status, whichever occurs first.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 30 June 2026
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 July 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5) High bilge levels. Bilge aft alarm inop. Prior to rectification, crew shall conduct hourly rounds of aft bilge during vessel operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 July 2023
Resolution: Vessel rectified bilge aft alarm audible and visual to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2023 Resolved
A fixed fire pump must be capable of: (1) a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)). Vessel's fire main had a gauge installed, but was inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 19 July 2023
Resolution: Vessel installed a new gauge on the fire main to satisfaction of Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2023 Resolved
Verification of compliance with the construction and arrangement design standards of this part [Part 144] must be performed before the new installation is performed. A new generator was installed on the vessel, which was not a replacement-in-kind, prior to completion of the verification of compliance. To show compliance and IAW 46 CFR 144.145 provide a copy of the verified plan to Sector UMR, OCMI and make vessel available for examination of new installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 2 August 2023
Resolution: Received objective evidence from PE that electrical modification plan and installation IAW approved standard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 June 2022 Resolved
The owner or managing operator must ensure the fire-detection system is maintained in accordance with the manufacturer's design manual. The horn/strobe indicator in the engine room does not strobe when the heat detection probes are activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 13 June 2022
Resolution: Received objective evidence from POC showing fire detection horn/strobe operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 June 2022 Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine RPM. No RPM gauge was present for the generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 14 June 2022
Resolution: Recieved objective evidence from POC showing installation of generator RPM gauge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2021 Resolved
Vessel required to be fitted with navigation lights to display when aground and not under command. Vessel not fitted with lights to display when around (nor "not under command" (Rule 27)) which are used to meet display requirements for meeting aground display requirements).
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 28 October 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2021 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Inspection found 160B semi-portable fire extinguisher is not permanently secured. Prove to the attending Coast Guard marine inspector that the extinguisher is properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 24 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 July 2020 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Whistle inoperable at time of inspection. Whistle required to be made operational.
Action required: 10 - Deficiency Rectified
Due 29 July 2020
Resolved 29 July 2020
Resolution: Whistle repaired; crew demonstrated proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 July 2020 Resolved
Work vest storage container not required to be marked with the words "Work Vest". Storage container not marked with the words "Work Vest". Required storage container to be properly marked, or, work vest removed from container.
Action required: 10 - Deficiency Rectified
Due 29 July 2020
Resolved 29 July 2020
Resolution: Work vest removed from storage container.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 May 2019 Resolved
Currently installed emergency lights failed to energize automatically as required. Install emergency lighting for all internal crew working areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Approved lighting installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 May 2019 Resolved
Portable, battery powered, light not installed at the access to the engine room. Install portable light at engine room access.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Portable lighting installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 May 2019 Resolved
Fire alarm horn/strobe (high decibel audio & visual strobe light) located at operating station is not able to be silenced or extinguished and has potential to significantly distract master's ability to operate vessel in a safe manner during an emergency. Remove horn/strobe from operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Fire alarm horn/strobe disabled.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 May 2019 Resolved
Fire detection system failed to actuate during testing of engine room heat detector. Repair system to ensure proper function from sensor in engine room.
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 May 2019
Resolution: Crew removed sensor, replaced with another sensor, and proved proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 May 2019 Resolved
Vessel's two lifebuoys were fitted with lifelines attached. Vessel required to have at least one lifebuoy without a lifeline attached. Ensure one lifebuoy does not have a lifeline attached.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: One PFD on board without lifeline.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 May 2019 Resolved
Records not available for lifesaving equipment testing and maintenance (as required by 46 CFR 199.190) to include date, name of person, and any receipts. Make records available for exam.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Records made available.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 May 2019 Resolved
Magnetic compass required to be illuminated. Wiring was not connected to illuminate compass. Connect wiring to properly illuminate compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Magnetic compass properly illuminated.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 May 2019 Resolved
Records not available for Safety Orientation Training (46 CFR 140.410), Navigation Safety Training (46 CFR 140.645), & Emergency Drills & Instruction for abandon vessel and response to threats to the environment (46 CFR 140.420(a)). Provide records with required entries to include training/drill date(s), description of training/drills, names of training/drill providers, names of training/drill participants. (Safety Orientation Training record required to include signature of individuals providing training.)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Records made available.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2019 Resolved
Fall overboard prevention procedures did not include use of personal protective equipment (if any), line handling safety, and safety moving to/from the vessel. Update procedures to include these items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 11 July 2019
Resolution: Procedures properly updated.