Records in 2023. Most recent: inspection, 21 April 2023.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)42.1 ft × 14.4 ft × 8.2 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKCS INTERNATIONAL · OCONTO, WI, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionUNSPECIFIED
Hull shapeShip
Hull configurationMonohull
Hailing portMIRAMAR BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 17 September 2014
Service, as the file records itPassenger (Uninspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
1 inspection, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2023
No resolution recorded
Official number not affixed perminently to interior as per 46CFR67.121.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2023
No resolution recorded
Employer & crew members not in chemical testing program as per 46CFR16.113.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2023
No resolution recorded
Employer & crew members not in random drug testing program as per 46CFR16.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2023
No resolution recorded
No alcohol testing kits on board as per 46CFR4.06-15.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 April 2023
No resolution recorded
No charts or nautical publications on board as per 46CFR26.03-4.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2023
No resolution recorded
Port side navigation light inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2023
No resolution recorded
Type 1 PFD, whistle, light for all on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2023
No resolution recorded
No Ring buoy on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 April 2023
No resolution recorded
Fire system in the engine room not inspected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023 — due date passed with no resolution recorded