DRUMMOND ISLANDER IV

DRUMMOND ISLANDER IV is a 2000 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in February 2026, along with 38 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 19 February 2026.

Built
2000
Last inspected
19 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE4153
Flag
UNITED STATES
Maury page id
psix-12967

Documentation record

Registered dimensions (L × B × D)142.1 ft × 40.0 ft × 12.0 ft
Registered tonnagegross 97 / net 65
ITC dimensions (L × B × D)142.1 ft × 40.0 ft × 12.0 ft
ITC tonnagegross 377 / net 113
BuilderBASIC MAINE INC · ESCANABA MICHIGAN · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDRUMMOND ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
113 - Convention (Subpart B), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
377 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 24

19 February 2026 In-Service Inspection · Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8313263
24 June 2025 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8126597
26 March 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8100436
17 July 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7969407
20 February 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7868074
2 December 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7832655
13 September 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7796065
31 October 2022 Hull Examination · Internal Structural Exam · Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7603110
17 October 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7583286
12 September 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7582734
25 October 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7338999
15 September 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7313438
5 June 2020 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6968676
14 October 2019 Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6836016
16 September 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6812684
1 July 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6742228
23 October 2018 Explosive Handling Operation-Commercial
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6566650
5 September 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6534818
17 January 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6339255
28 September 2017 Hull Examination · Annual Inspection · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277207
6 June 2017 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6168624
20 December 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6072506
6 December 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6053189
1 September 2016 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5989930

Deficiency record · 38

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 February 2026 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port engine coolant temperature gauge is not operating as intended. Make repairs to the satisfaction of attending CG Marine Inspectors. 46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 4 March 2026
Resolution: Received attestation and photos depicting port MDE coolant temp sensor replacement & properly operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. To address the rudder issue, the crew replaced the two missing bolts and used an impact gun to torque the nuts. As a temporary measure, since welding underwater was not feasible, an air hammer chisel was used to bend and distort the bolt threads behind the nut to prevent it from falling off if it were to become loose. Make permanent repairs to the satisfaction of attending CG Marine Inspectors prior to 01JUN2026. 46CFR182.100
Action required: 705 - Other - as specified
Due 1 June 2026
Resolved 28 February 2026
Resolution: Long term temp repairs (with the possibility of being determined permanent after regular inspections via camera, and close visual inspection at next vessel hull exam, due NLT Oct 2027) were completed by underwater dive/repair experts, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2025 Resolved
Void below pilothouse: Battery box requires chocks; Steering motor must be monitored for leaks. 46 CFR 175-185
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 10 July 2025
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2025 Resolved
PFD's must be cleaned and stowed to be readily donned. 46 CFR 175-185
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 10 July 2025
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2025 Resolved
Both shaft packings must be monitored for excessive fresh water intusion into the engineroom bilge. Engineroom bilge must be kept free of excessive water in accordance with the vessels issued stability letter. 46 CFR 175-185
Action required: 10 - Deficiency Rectified
Due 24 June 2025
Resolved 24 June 2025
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2025 Resolved
Stbd MDE supply fuel line is chafed, must be replace. 46 CFR 175-185
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 10 July 2025
Resolution: replaced
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 24 June 2025 Resolved
Engineroom flammables and combustibles must minimized/removed from the main space. Alternatively, flammables may be stored in a properly secured UL approved flammable locker. 46 CFR 175-185
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 10 July 2025
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. While getting underway from the pier the vessel experienced a failure of one of the main diesel engines. It was determined silicone had fallen into the fuel tank during dry dock, resulting in the clogging of the fuel filter and the engine failure. Fuel filters were cleaned and engine resumed operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 December 2023
Resolved 2 December 2023
Resolution: Crew was able to clean fuel filters. Company will continue to monitor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2022 Resolved
Red hazmat light inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 13 September 2022
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 September 2022 Resolved
Rudder room bilge alarm inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 13 September 2022
Resolution: corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 September 2022 Resolved
emergency fuel shut-off break glass is broken, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 13 September 2022
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 15 September 2021 Resolved
Stern portside ramp cable frayed, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2021
Resolved 6 October 2021
Resolution: replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 September 2021 Resolved
Camera and computer equipment must be properly secured or removed from closet in pax accom. space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 25 October 2021
Resolution: Received photos depicting correction.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 September 2021 Resolved
FFE system flexible loop piping hydro-static testing required. Subject piping to hydro-static testing or replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 6 October 2021
Resolution: replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 September 2019 Resolved
Provide technician report attesting to satisfactory inspection and testing of fixed gas fire extinguishing system. 46 CFR 176.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2019
Resolved 11 October 2019
Resolution: report recieved, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 September 2019 Resolved
Both main deck life ring buoys deteriorated, must be replaced. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 21 October 2019
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 September 2019 Resolved
Main deck must be appropriately marked to ensure vehicles do not block engine room emergency exit hatch. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 21 October 2019
Resolution: marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2019 Resolved
Remove "dead end" wire from electrical space below the pilot house. 46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 21 October 2019
Resolution: Wiring purposely left for possible future use. Confirmed safe, coiled/properly stored and tagged for future indentification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2019 Resolved
Secure battery box and chock battery inside box in electrical space below the pilot house. 46 CFR 350(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 21 October 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2019 Resolved
Steering gear hydraulic fluid lines to steering rams show signs of small leaks. Repair and make available to in-service inspection NLT 30 Sept. 46 CFR 176.814
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 21 October 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2018 Resolved
The weather deck screw down valve for the collision bulkhead bilge pipe was seized. Maintenance personnel modified the valve reach rod to make valve operational. Valve can only be operated by removing the fwd compartment access cover which does not specifically meet the regulation, meets the intent.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 September 2018
Resolved 5 September 2018
Resolution: Corrected on the spot.
Documentation › Markings/Placards › Warning Signs
Issued 21 December 2017 Resolved
Reduction gear manual controls must be labeled appropriately.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 17 January 2018
Resolution: Labeled.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 December 2017 Resolved
Remount broken steering compartment lighting fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 17 January 2018
Resolution: Mounted.
Engineering › Bilge Water Management System › Strainer
Issued 21 December 2017 Resolved
Remove all rags and housekeeping items from lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 17 January 2018
Resolution: Laz cleaned and items removed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 December 2017 Resolved
Provide detailed fire fighting equipment servicing report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 17 January 2018
Resolution: Received report and confirmed proper servicing on board vessel.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 September 2017 Resolved
Replace missing windows in Fire Detection Control Panel cover as to prevent accidental contact with electrical components.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 17 January 2018
Resolution: Replaced.
Communications › Internal Communications System › Sound-powered Telephone
Issued 28 September 2017 Resolved
Repair and prove proper operation of sound-powered telephone as primary communication between wheelhouse and engineroom propulsion control station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 17 January 2018
Resolution: Proper operation proved.
Fire Fighting › Fire Hoses › Material
Issued 20 December 2016 Resolved
Fire hose in passenger cabin is not UL Listed, is not lined cotton hose, to be corrected. Existing hose is resilient material, USMHSA approved with aluminum end fittings.
Condition: Improper Installation
Due 12 January 2017
Resolved 12 January 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 December 2016 Resolved
Demonstrate audible alarms for bilge alarms in pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 12 January 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 December 2016 Resolved
Retroreflective tape applied incorrectly on all ring buoys. Re-mark all ring buoys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 20 December 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 December 2016 Resolved
Provide blocks in all battery boxes to prevent battery movement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 20 December 2016
Fire Fighting › Combustible Materials › Insulation
Issued 6 December 2016 Resolved
Install oil resistant insulation on exposed hot areas of exhaust turbocharger inlets on both main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 12 January 2017
Documentation › Markings/Placards › Oil Discharge Placard
Issued 6 December 2016 Resolved
Post oil pollution discharge placard in engineroom near bilge pump controller.
Condition: Improper/Lack of Maintenance
Due 6 January 2017
Resolved 20 December 2016
Fire Fighting › Fire Hoses › Condition
Issued 6 December 2016 Resolved
Fire hose on upper deck leaked excessively at connection to hydrant, replaced during inspection.
Condition: Improper/Lack of Maintenance
Due 6 December 2016
Resolved 6 December 2016
Engineering › Fuel Oil Service System › Suction Strainer
Issued 6 December 2016 Resolved
Main fuel oil suction strainer was clogged, (not cleaned periodically), resulting in short term electrcial power failure during inspection, corrected prior to loading passengers.
Due 6 December 2016
Resolved 6 December 2016
Documentation › Certificates/Documents › Stability Letter
Issued 6 December 2016 Resolved
Stability letter improperly posted, not in view of operating station, not all pages visible. Corrected during inspection.
Condition: Improper Installation
Due 6 December 2016
Resolved 6 December 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2016 Resolved
Provide record of training for responsibilities of crew members in an emergency.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 2 September 2016
Resolution: proper entries recorded in log book.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2016 Resolved
Provide record of fire, abandon ship, and man overboard training.
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 2 September 2016
Resolution: proper entries recorded in log book.