Records from 2017 to 2025. Most recent: inspection, 22 August 2025.
Inspection history · 7
22 August 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8215752
16 August 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8211085
12 July 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8183265
17 April 2023
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670160
8 October 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7329094
27 July 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6492322
4 January 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6065500
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2018
Resolved
Means shall be provided to control leak of flammable liquids. MDE is leaking excessively from cylinder heads at o-rings and fuel supply lines from fuel pumps.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2018
Resolved 31 July 2018
Resolution: New o-rings were installed to stop leaks.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2018
Resolved
Means shall be provided to control leak of flammable liquids. Excess oil is present in bilge iwo MDE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2018
Resolved 31 July 2018
Resolution: Excessive oil was pumped out of the bildge.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 July 2018
Resolved
Fire proectection systems and fire fighting systems shall be maintained ready for use. UV flame detector tubes over the #1 SSDG and Boiler on main deck of engine room are missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2018
Resolved 31 July 2018
Resolution: Replaced UV flame detector tubes.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 29 July 2018
Resolved
Enclosed space entry drill shall be held on board the ship at least every two months. Records for drill are unable to be provided.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2018
Resolved 31 July 2018
Resolution: Crew conducted enclosed space entry drill.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 July 2018
Resolved
Fire protection systems and fire fighting systems shall be maintained ready for use. Smoke detector oin the EDG space is ziptied to frame beacuse it randomly sounds alarm due to vibrations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2018
Resolution: tech report
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 July 2018
Resolved
Fire fighting systems shall be maintained ready for use. Fire main on both sides of main deck have soft patches for temporary repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2018
Resolution: tech report
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 July 2018
Resolved
Master or c/o must provide written records for ballast water reporting iaw 33CFR 151.2070 either in writing or electronically to the National Ballast Information Clearinghouse on the Ballast Water Reporting Form. Master was unaware of this requirement and no report was submitted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2018
Resolved 31 July 2018
Resolution: Master submitted ballast water report to NBIC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 July 2018
Resolved
Vessel is required to have a Vessel General Permit and submit a Notice of Intent to operate in US waters. Master had no knowledge of the requirement that vessel have a VGP and no VGP or NOI are available for vsl.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2018
Resolution: tech report