← All vessels
MISS MARGY
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Great Lakes District (CGD-GL) · Other hulls named MISS MARGY
MISS MARGY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2016, most recently in August 2025, along with 34 deficiencies and 1 casualty investigation in 2023.
Records from 2016 to 2025. Most recent: inspection, 20 August 2025.
- Built
- 2015
- Last inspected
- 20 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
1263723
WCY2616
1297305
Flag
UNITED STATES
367721890
Maury page id
psix-1297305
Inspections, by type
…with no type recorded3
Years with a record
10 calendar years (2016–2025)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)79.1 ft × 21.5 ft × 8.8 ft
Registered tonnagegross 83 / net 57
ITC dimensions (L × B × D)79.1 ft × 21.5 ft × 8.8 ft
ITC tonnagegross 128 / net 66
BuilderMORAN IRON WORKS INC · ONAWAY, MI, UNITED STATES · built 2015
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAW CITY, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it128 - Convention (Subpart B), Gross Ton
83 - Regulatory (Subpart C or D), Gross Ton
91 - Displacement, Ton
66 - Convention (Subpart B), Net Ton
57 - Regulatory (Subpart C or D), Net Ton
83 - Regulatory (Subpart C or D), Gross Ton
91 - Displacement, Ton
66 - Convention (Subpart B), Net Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI6756MMSI 367721890 · active · compulsorily equipped · granted 10 April 2026, expires 18 March 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 33
20 August 2025
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8215599
5 May 2025
MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8113859
4 March 2025
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8098567
22 October 2024
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8037802
9 July 2024
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7954179
26 September 2023
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7827731
23 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7757050
12 July 2023
Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7746940
6 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7742301
15 April 2023
Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7688870
19 December 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7610999
3 October 2022
Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7572999
19 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7434874
14 February 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7396094
27 September 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7339201
25 June 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6986259
15 June 2020
MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6976968
11 December 2019
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6873517
9 December 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6869775
28 October 2019
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6860592
13 August 2019
Type not recorded
No type recorded · Station St Ignace · USCG Great Lakes District (CGD-GL) · Activity 6782848
11 April 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6667725
17 January 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6612233
7 December 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619799
27 September 2018
Annual Inspection · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6561229
18 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6543255
3 April 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599831
3 April 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619612
29 September 2017
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277747
1 May 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6142777
26 October 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6036670
23 September 2016
Plan Review (Other than "T")
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6011415
20 September 2016
DAPI Audit
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6046081
Deficiency record · 34
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2023
Resolved
Found one blade of the center prop gone and broke clean off with no damage to the hull. Upon removal of the prop mechanics found a hairline fracture with the help of dye penetrant. Shaft was run out and a replacement was ordered. Company had a replacement prop on hand and replaced all three. Vessel was given permission to run on the two outboard engines until replacement shaft comes in from the CID.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2022
Resolved
A/C "chiller" void (void #2) smoke/heat detector is sounding an error alarm at the panel, so not reliable. Vendor has been notified. Crew must make hourly rounds of that space. Detector must be corrected and tested, report must be submitted to CG inspections office SSM.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 October 2022
Resolved
Sighted multiple cracked welds in #2 void. Stress cracks initiated at certain welds and have traveled into primary structural plate - 3rd primary transverse structure from WTB at the chine on both sides of vessel. Engage Naval Architect, submit repair proposal and effect permanent repairs after approval of plan.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 3 October 2022
Resolved
Sighted 10-12 upper deck seats broken making them a hazard to passengers. Remove and replace, cordon off seats and limit passenger count until corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 27 September 2021
Resolved
10-12 seats are cracked and require replacement.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 September 2021
Resolved
EPIRB batgtery is expired. Replace battery or EPIRB.
** Vessel is limited to NMT 3 NM from land until corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2021
Resolved
RLB lights inop, corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 September 2021
Resolved
simple instructions must be posted at the fire bottles.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2021
Resolved
fantain junction box broken, must be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2020
Resolved
Vessel's visual distress signals are expired MAY 2020. Replace expired flares.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 October 2019
Resolved
Make permanent repairs to multiple cracked welds in #2 & #3 voids.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 September 2018
Resolved
Repair forepeak and #1 void weld fractures.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 September 2018
Resolved
Properly re-install fuel tank void overhead insulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 September 2018
Resolved
Metallic sections of fuel fill piping must be bonded by a conductor.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 September 2018
Resolved
Replace 4 expired distress signals. Properly label watertight container with "DISTRESS SIGNALS"
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 September 2018
Resolved
Correct steering system linkage adjustment and demonstrate proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2018
Resolved
Properly mark ring life buoys with vessel name (missing letters).
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 September 2018
Resolved
Electrical compartment batteries must be properly chocked to prevent shifting.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 September 2018
Resolved
EPIRB hydrostatic release is expired. Replace hydrostatic release prior to operating beyond 3 NM from shore.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018
Resolved
The vessel is currently broadcasting (1) Improper Call Sign, (2) Zero Length and Beam, (3) Zero Draft.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 September 2017
Resolved
Discharge hoses were loose at cylinder heads, not tightened after recent servicing, corrected.
Lifesaving › Lifebuoys › Immediately Available
Issued 29 September 2017
Resolved
Ring Buoy on fantail obstructed by improper housekeeping, corrected during inspection.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 29 September 2017
Resolved
Terminals loose on main engine cranking batteries, corrected immediately
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 September 2017
Resolved
P/S F/O Tank mounting/securing bolts loose, corrected on spot.
Fire Fighting › Fire Hydrants › Condition
Issued 29 September 2017
Resolved
Spanner wrenches not located at each fire hydrant, corrected on spot.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 29 September 2017
Resolved
Box missing for distress signals, corrected on spot.
Documentation › Certificates/Documents › Stability Letter
Issued 26 October 2016
Resolved
Post stability letter at operating station.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 26 October 2016
Resolved
Provide Sr. deckhand personnel list on board vessel.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 October 2016
Resolved
Test EPIRB and log monthly tests.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 October 2016
Resolved
All hatch covers exposed to weather must have a securing device to vessel per 46CFR116.1160.
Engineering › Steering Gear System › Piping
Issued 26 October 2016
Resolved
Replace/repair cheffed steering gear hydraulic line on port rudder and properly support unsupported main hydraulic line running between rudders.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 26 October 2016
Resolved
Demonstrate understanding and functionality of newly approved and delivered PTSP's.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 September 2016
Resolved
Only had pre-employment records back to 2013
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 September 2016
Resolved
Supervisors do not have one hour training required to do reasonable cause testing.
Casualty record · 1
6 July 2023Routine · role: Involved in a Marine Casualty · activity 7742301
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.