Records from 2016 to 2025. Most recent: inspection, 20 August 2025.
Inspection history · 33
20 August 2025
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8215599
5 May 2025
MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8113859
4 March 2025
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8098567
22 October 2024
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8037802
9 July 2024
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7954179
26 September 2023
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7827731
23 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7757050
12 July 2023
Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7746940
6 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7742301
15 April 2023
Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7688870
19 December 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7610999
3 October 2022
Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7572999
19 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7434874
14 February 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7396094
27 September 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7339201
25 June 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6986259
15 June 2020
MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6976968
11 December 2019
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6873517
9 December 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6869775
28 October 2019
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6860592
13 August 2019
Type not recorded
No type recorded · Station St Ignace · USCG Great Lakes District (CGD-GL) · Activity 6782848
11 April 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6667725
17 January 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6612233
7 December 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619799
27 September 2018
Annual Inspection · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6561229
18 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6543255
3 April 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599831
3 April 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619612
29 September 2017
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277747
1 May 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6142777
26 October 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6036670
23 September 2016
Plan Review (Other than "T")
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6011415
20 September 2016
DAPI Audit
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6046081
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2023
Resolved
Found one blade of the center prop gone and broke clean off with no damage to the hull. Upon removal of the prop mechanics found a hairline fracture with the help of dye penetrant. Shaft was run out and a replacement was ordered. Company had a replacement prop on hand and replaced all three. Vessel was given permission to run on the two outboard engines until replacement shaft comes in from the CID.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 17 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2022
Resolved
A/C "chiller" void (void #2) smoke/heat detector is sounding an error alarm at the panel, so not reliable. Vendor has been notified. Crew must make hourly rounds of that space. Detector must be corrected and tested, report must be submitted to CG inspections office SSM.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 6 October 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 October 2022
Resolved
Sighted multiple cracked welds in #2 void. Stress cracks initiated at certain welds and have traveled into primary structural plate - 3rd primary transverse structure from WTB at the chine on both sides of vessel. Engage Naval Architect, submit repair proposal and effect permanent repairs after approval of plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2022
Resolved 15 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 3 October 2022
Resolved
Sighted 10-12 upper deck seats broken making them a hazard to passengers. Remove and replace, cordon off seats and limit passenger count until corrected.
Action required: 10 - Deficiency Rectified
Due 3 October 2022
Resolved 3 October 2022
Resolution: Corrected prior to my departure.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 27 September 2021
Resolved
10-12 seats are cracked and require replacement.
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 19 April 2022
Resolution: replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 September 2021
Resolved
EPIRB batgtery is expired. Replace battery or EPIRB.
** Vessel is limited to NMT 3 NM from land until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 20 December 2021
Resolution: received information from the company POC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2021
Resolved
RLB lights inop, corrected.
Action required: 10 - Deficiency Rectified
Due 27 September 2021
Resolved 27 September 2021
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 September 2021
Resolved
simple instructions must be posted at the fire bottles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 19 April 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2021
Resolved
fantain junction box broken, must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 26 October 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2020
Resolved
Vessel's visual distress signals are expired MAY 2020. Replace expired flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 25 June 2020
Resolution: Replaced
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 October 2019
Resolved
Make permanent repairs to multiple cracked welds in #2 & #3 voids.
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 11 December 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 September 2018
Resolved
Repair forepeak and #1 void weld fractures.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2019
Resolved 11 April 2019
Resolution: repaired.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 September 2018
Resolved
Properly re-install fuel tank void overhead insulation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2019
Resolved 11 April 2019
Resolution: re-installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 September 2018
Resolved
Metallic sections of fuel fill piping must be bonded by a conductor.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: bonding material installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 September 2018
Resolved
Replace 4 expired distress signals. Properly label watertight container with "DISTRESS SIGNALS"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 17 January 2019
Resolution: replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 September 2018
Resolved
Correct steering system linkage adjustment and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: linkage adjusted, operational chack completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2018
Resolved
Properly mark ring life buoys with vessel name (missing letters).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 September 2018
Resolved
Electrical compartment batteries must be properly chocked to prevent shifting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 17 January 2019
Resolution: corrected.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 September 2018
Resolved
EPIRB hydrostatic release is expired. Replace hydrostatic release prior to operating beyond 3 NM from shore.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: replaced and properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018
Resolved
The vessel is currently broadcasting (1) Improper Call Sign, (2) Zero Length and Beam, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 1 May 2019
Resolution: Received notification of AIS broadcasting correction from vessel owner. Verified no errors in VIVS.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 September 2017
Resolved
Discharge hoses were loose at cylinder heads, not tightened after recent servicing, corrected.
Condition: Improper/Lack of Maintenance
Due 29 September 2017
Resolved 29 September 2017
Resolution: corrected during inspection.
Lifesaving › Lifebuoys › Immediately Available
Issued 29 September 2017
Resolved
Ring Buoy on fantail obstructed by improper housekeeping, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 29 September 2017
Resolved 29 September 2017
Resolution: corrected.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 29 September 2017
Resolved
Terminals loose on main engine cranking batteries, corrected immediately
Condition: Improper/Lack of Maintenance
Due 29 September 2017
Resolved 29 September 2017
Resolution: corrected on spot
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 September 2017
Resolved
P/S F/O Tank mounting/securing bolts loose, corrected on spot.
Condition: Improper/Lack of Maintenance
Due 29 September 2017
Resolved 29 September 2017
Fire Fighting › Fire Hydrants › Condition
Issued 29 September 2017
Resolved
Spanner wrenches not located at each fire hydrant, corrected on spot.
Condition: Improper Installation
Due 29 September 2017
Resolved 29 September 2017
Lifesaving › Visual Distress Signals (General) › Storage
Issued 29 September 2017
Resolved
Box missing for distress signals, corrected on spot.
Condition: Improper Installation
Due 29 September 2017
Resolved 29 September 2017
Documentation › Certificates/Documents › Stability Letter
Issued 26 October 2016
Resolved
Post stability letter at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Posted.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 26 October 2016
Resolved
Provide Sr. deckhand personnel list on board vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Sighted.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 October 2016
Resolved
Test EPIRB and log monthly tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Sighted.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 October 2016
Resolved
All hatch covers exposed to weather must have a securing device to vessel per 46CFR116.1160.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Secured.
Engineering › Steering Gear System › Piping
Issued 26 October 2016
Resolved
Replace/repair cheffed steering gear hydraulic line on port rudder and properly support unsupported main hydraulic line running between rudders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Corrected.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 26 October 2016
Resolved
Demonstrate understanding and functionality of newly approved and delivered PTSP's.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 29 September 2017
Resolution: No revision necessary, requirment is cancelled, see narrative this date.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 September 2016
Resolved
Only had pre-employment records back to 2013
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 20 September 2016
Resolution: Told them to add notes to files for employees that do not have pre-employment test records and to save oldest available random test.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 September 2016
Resolved
Supervisors do not have one hour training required to do reasonable cause testing.
Condition: Invalid
Due 20 September 2016
Resolved 20 September 2016
Resolution: Company will provide neccessary training.