MAURY USCG vessel records
← All vessels

BELMONTE

BELMONTE is a 2014 freight ship. The Coast Guard has recorded 7 inspections since 2017, most recently in December 2024, along with 3 deficiencies.

Records from 2017 to 2024. Most recent: inspection, 16 December 2024.

Built
2014
Last inspected
16 December 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 December 2024
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9687124
1297426
Flag
LIBERIA
Maury page id
psix-1297426

Documentation record

Tonnage as PSIX records it43068 - Convention (Subpart B), Gross Ton
26784 - Convention (Subpart B), Net Ton
81344 - Dead Weight, Metric Ton
94002 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

7 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

16 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048137
29 September 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7786701
7 August 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7272863
25 November 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6586134
13 June 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6442914
24 November 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6312085
18 May 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6140574

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 September 2023 Resolved
The machinery and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed exhaust gas leaking from A/E No. 2. 74SOLAS(20)II-1/26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2023
Resolved 30 September 2023
Resolution: Crew replaced by OEM original parts and engine tested, class report attached attesting to repairs.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 September 2023 Resolved
The jacketed piping system shall include a means for collecting of leakages and arrangements shall be provided with an alarm in case of a fuel line failure. PSCO observed F/O leak alarm on A/E No. 3 inoperable. 74SOLAS(09)II-2/4.2.2.5.2 50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2023
Resolved 30 September 2023
Resolution: FO leak alarm on A/E no. 3 repaired and tested satisfactory, class report attests to repairs.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Approved method
Issued 7 August 2021 Resolved
The company and the ship shall comply with the requirements of the ISM Code. Every company should designate a person ashore. the responsibility of the designated person should include monitoring the pollution-prevention aspects of the operation of each ship. PSCO witnessed lack of understanding and familiarization surrounding use of exhaust gas scrubber system and United States regulations allowing use of alternative means. 74SOLAS(20)IX/3.1 ISM Code reg 4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2021
Resolved 7 August 2021

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.