MAURY USCG vessel records
← All vessels

TRADEWIND LEGEND

TRADEWIND LEGEND is a 2008 tank ship. The Coast Guard has recorded 1 inspection in 2019, along with 2 deficiencies — 2 with no resolution recorded —.

Records in 2019. Most recent: inspection, 6 May 2019.

Built
2008
Last inspected
6 May 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2019
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9503940
1300011
Flag
PANAMA
Maury page id
psix-1300011

Documentation record

Tonnage as PSIX records it5001 - Convention (Subpart B), Gross Ton
2411 - Convention (Subpart B), Net Ton
7732 - Dead Weight, Metric Ton
10687 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

6 May 2019 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6676544

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2019 No resolution recorded
The fixed fire detection and fire alarm system shall be so designed and the detectors so positioned as to rapidly detect the onset of fire in any part of those spaces. The fire detectors in Zones 2 & 3 (Generator Area), Zone 4 (Incinerator Area) and Zone 6 (Boiler Area) were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 May 2019 No resolution recorded
The company should establish procedures for the implementation of corrective action, including measures to prevent recurrence. No corrective action from company has been established since April 8, 2019.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.