Records from 2015 to 2026. Most recent: inspection, 2 July 2026.
Inspection history · 19
2 July 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8426342
1 July 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8421543
27 June 2026
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8416929
28 May 2025
PSC B · COC-CHEM Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8145833
28 May 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8145884
27 May 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8146380
14 April 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7894814
11 January 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7620313
17 October 2022
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7573665
17 September 2021
COC-CHEM Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7314247
8 February 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7137254
4 September 2020
PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7044640
26 December 2019
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6878991
6 August 2019
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6774862
1 July 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6731859
6 December 2017
COC-CHEM & TVE Annual · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6315398
12 April 2017
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6122859
26 November 2016
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6047630
24 July 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5194207
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 17 October 2022
Resolved
74 SOLAS (2020) II-2/4.5.7.3.1, FSS CODE (2015) 16.2.2.2.1.4. In addition to the requirements in paragraphs 5.7.1 and 5.7.2, oil tankers of 20,000 tonnes deadweight and above, constructed on or after 1 January 2012, shall be provided with a fixed hydrocarbon gas detection system complying with the Fire Safety Systems Code. The hydrocarbon gas detection equipment including sample piping, sample pumps, solenoids, analysis units, etc., shall be located in a reasonably, gas tight cabinet which is to be monitored by its own sampling point. PSCO observed sample point 00 which serves the cabinet provides flow alarm. Crew stated the flow was too high and therefore giving the flow alarm. Provide class report prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2022
Resolved 18 October 2022
Resolution: Received and accepted class report from DNV stating the deficiency was rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 17 October 2022
Resolved
No direct access shall be permitted between the machinery space and the space containing the emergency fire pump and its source of power. When this is impracticable, the administration may accept an arrangement where the access is by means of an airlock with both doors being at least steel, both reasonably gas tight, self-closing, and without any hold back arrangements. PSCO noticed the door adjacent to the steering gear room to not be self closing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2022
Resolution: Received and accepted class report from DNV stating the deficiency was rectified.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 6 December 2017
Resolved
Personal equipment shall consist of the following: protective clothing to material to protect the skin from heat radiating from the fire and from burns and scalding. One of the fire fighter's outfits has significant wear on the jacket and pants, where the metallic material has rubbed off exposing the jacket's underlying material affecting the integrity of the fire fighter's outfit. 74SOLAS(2014) II-2/10.10.1.1 FSS 3.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2017
Resolution: Received Class Report allowing vessel to sail.