MAURY USCG vessel records
← All vessels

BLUE AKIHABARA

BLUE AKIHABARA is a 2014 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in July 2026, along with 7 deficiencies and 2 operational controls.

Records from 2017 to 2026. Most recent: inspection, 29 July 2026.

Built
2014
Last inspected
29 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9696785
1300348
Flag
PANAMA
Maury page id
psix-1300348

Documentation record

Tonnage as PSIX records it34617 - Convention (Subpart B), Gross Ton
61630 - Dead Weight, Metric Ton
72397 - Displacement, Metric Ton
20170 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

11 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

29 July 2026 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8449938
14 July 2026 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8431373
6 March 2023 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7645868
4 March 2023 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7657998
17 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610431
16 December 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610196
14 December 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7600287
26 September 2018 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6540451
22 July 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6217234
10 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6191618
8 July 2017 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 6201624

Deficiency record · 7

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 July 2026 Resolved
The opening below the lowest course of the guard rails shall not exceed 230mm. PSCO observed broken rung on stbd side near cargo hold two. ILLC 25.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2026
Resolution: Vessel Cut and removed broken lower guard rails and welded with new round solid bar.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2026 Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed damaged cable run for emergency light near free fall lifeboat 74SOLAS(24)11-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2026
Resolution: Vessel Pulled-out and renewed Damaged Electrical Cable with new spare electrical wire.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 July 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed deteriorated SOLAS tape on free fall lifeboat 74SOLAS(24)111/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 July 2026
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 July 2026 Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by the crew shall be supplied from the main source of electrical power. PSCO observed 09 lights out in engine room
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 July 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 December 2022 Resolved
Alleyways, stairways, and exits, giving access to the muster and embarkation stations shall be lighted. PSCO observed 06 emergency lights surrounding the pilothouse missing or non-functional. 74SOLAS(20) III/11.5 Action Taken: 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 15 December 2022
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Crew replaced and tested all emergency lights surrounding the Pilot house.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 December 2022 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting. PSCO observed embarkation lights on port and starboard side non-functional. 74SOLAS(20) III/11.4 Action Taken: 10c
Action required: 10 - Deficiency Rectified
Due 14 December 2022
Resolved 14 December 2022
Resolution: Vessel replaced lightbulbs on port and starboard embarkation lights prior to PSCO departing from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2022 Resolved
The machinery, boilers, and other pressure vessels, associated piping, systems, and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed lube oil leak on connections coming from stern tube gravity tank. 74SOLAS(14) II-1/26.1 Action Taken: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 15 December 2022
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Crew removed and inspected hydraulic line and also properly tightened all fittings with no further leakage.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.