This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it17019 - Simplified, Gross Ton 10108 - Simplified, Net Ton 17019 - Convention (Subpart B), Gross Ton 28340 - Dead Weight, Metric Ton 34767 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
15 April 2021PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7163813
27 June 2019Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6721185
24 April 2019Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6650543
6 January 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6606147
22 March 2018PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6375556
23 January 2017ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6075052
11 January 2016ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5787987
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 January 2017Resolved
0715: The function of the fixed fire detection system shall be periodically tested by means of equipment producing phenomena associated with incipient fires to which the detector is designed to respond. Crew is using a cigarette lighter to test flame detectors, 74 SOLAS (14) II-2/7.3.2, 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2017
Resolution: Vessel's Captain purchased a heat detector test kit.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 23 January 2017Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible to understand and follow it. Vessel currently is not following the Ballast Water Management Plan including the Bio-Fouling, 33CFR151.2050(g), 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Discussed Ballast and Bio-Fouling Plans with the [name withheld] and Chief Engineer.
Operations/Management › Drills/Instruction › Fire
Issued 23 January 2017Resolved
3032: Drills shall as far a practicable, be conducted as if there were an actual emergency. Vessel's crew failed the first fire drill due to lack of boundary cooling and conflict between security and safety. After a brief discussion the crew passed the second drill, 74 SOLAS (14) III/19.3.1, 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Discussed items with the Entire Crew, Reviewed SOLAS Fire Fighting and Training Manuals.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.