CLOUDIA is a 1934 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2017, most recently in February 2026, along with 15 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 23 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)49.1 ft × 16.7 ft × 8.5 ft
Registered tonnagegross 34 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAGWAG, NORWAY · built 1934
Hull materialWood
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, restricted
DocumentationValid · issued 15 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton 31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
23 February 2026COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8314375
6 March 2025Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8089600
16 August 2024In-Service Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7982699
11 September 2023Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789736
29 March 2023Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646221
21 July 2022Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489974
5 May 2021Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188227
14 September 2020Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7057654
7 October 2019Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6831038
2 October 2019Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6826883
Vessel failed to complete an annual inspection in 2024, and is over 3 months past its anniversary date. Vessel is prohibited from carrying passengers until the annual inspection is complete.
Action required: 705 - Other - as specified
Resolved 11 September 2024
Resolution: Annual Inspection completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 August 2024Resolved
Provide labeling at fuel valve shutoff pull handles to indicate port tank / stbd tank / aft tank. Recommend labeling "test the functionality of remote shut off valves prior to starting engines"
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 14 September 2024
Resolution: Received photos of posted signage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 August 2024Resolved
Flammable liquids were found stored in the forward compartment. Remove all flammable liquids from the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 14 September 2024
Resolution: Received photos of flammables removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 August 2024Resolved
The forward emergency escape was found to be blocked by the storage of gear. Make escape ladder accessible prior to carriage of passengers.
46 CFR 177.500
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 14 September 2024
Resolution: Received photos of area cleared out.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 September 2023Resolved
Vessel rep was not comfortable getting underway due to windy conditions. Conduct underway drills with attending MI.
Action required: 705 - Other - as specified
Due 11 October 2023
Resolved 15 September 2023
Resolution: Witnessed satisfactory drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2023Resolved
The main engine raw water pump was found loose and not properly fastened to the engine block.
Action required: 10 - Deficiency Rectified
Resolved 11 September 2023
Resolution: Bolts were tightened and correct on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2022Resolved
One portable fire extinguisher was more than six months past due for servicing. Complete servicing on identified fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: Fire extinguisher was serviced by Johnson Controls on 01 August 2022.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2022Resolved
Sail rigging preventative maintenance plan (PMP) did not have an examination/maintenance schedule. Vessel must expand its rigging PMP to include an examination/maintenance schedule as described in the USCG Sail Rigging NVIC (02-16).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 3 August 2022
Resolution: Vessel drafted a rigging inspection schedule.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 September 2020Resolved
Engine compartment bilge alarm did not alarm at operator station when tested.
Action required: 10 - Deficiency Rectified
Resolved 14 September 2020
Resolution: Crew troubleshot and repaired bilge alarm.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 September 2020Resolved
Provide DSC VHF radio with vessel's GPS input. 47 CFR 13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2020
Resolved 19 October 2020
Resolution: Vessel rep emailed photo with new radio installed and GPS coordinates displayed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2020Resolved
Replace warned grab line on vessel's life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2020
Resolved 19 October 2020
Resolution: Vessel rep emailed photo of new life ring, with vessel name and retroreflective tape.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 October 2019Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 by the vessel owner or a third party. Vessel did not complete required annual inspections on portable fire extinguishing equipment and pre engineered fire fighting equipment. Vessel operator must complete required maintenance and inspection and provide proof to CG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 24 October 2019
All inspected small passenger vessels must undergo an annual inspection within the three months before or after each anniversary date on their Certificate of Inspection (COI). As of September 17, 2019, your vessel is past due on their COI annual inspection. Vessel is restricted from operating until a COI annual inspection has been completed by CG Marine Inspectors.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 7 October 2019
Resolution: COI annual conducted on 7 OCT 2019
Documentation › Markings/Placards › Official Number (US)
Issued 10 August 2017Resolved
Permanetly affix the official number IAW 46 CFR 67.121
Condition: Placed in Improper Service
Due 10 September 2017
Resolved 31 August 2017
Resolution: The Official number is now affixed.
Provide FCC form 824; Communications act safety radio telephony certificate onboard.
Condition: Placed in Improper Service
Due 10 September 2017
Resolved 31 August 2017
Resolution: FCC form is now valid and onboard
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.