Records from 2004 to 2025. Most recent: inspection, 16 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
16 December 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8279178
9 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8277033
24 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8098524
31 January 2024
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7858702
29 November 2023
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7832433
18 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7670760
3 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7443408
8 March 2022
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7407516
22 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7180405
28 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6944888
23 April 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6942746
8 March 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6641281
22 January 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6613081
23 April 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6397234
22 February 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6360137
20 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6127771
19 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5857770
23 March 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5837738
28 October 2014
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5012835
20 June 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4350129
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200324
7 January 2011
Annual Inspection · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3922544
25 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3439720
20 January 2009
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3397557
8 January 2009
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3391002
1 May 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3196385
16 November 2007
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3126679
25 October 2007
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3091450
23 January 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2863299
1 February 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2628459
16 January 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2575859
6 December 2005
Re-Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2546662
5 May 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2350230
12 February 2004
COI Inspection · Simplified Stability Test · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1946158
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 March 2025
Resolved
Main propulsion machinery shall be installed in a manner to protect against fire. Oil pressure sensor on starboard main diesel engine had steady drip of fuel, presenting potential fire hazard.
Cite not listed in MISLE, below is cite for deficiency
Cite: 46 CFR 182.01-5 OLD "T"
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2025
Resolution: Vessel owner procured new oil pressure sensor and replaced the leaking sensor on the port MDE. Verified that the sensor no longer leaks fuel at reattendance.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 March 2025
Resolved
At each inspection, marine inspector shall examine all accessible parts of the exterior and interior of the hull. Pinhole leak was found forward of check valve on the AC drain line.
Cite not listed in MISLE, below is cite for deficiency
Cite: 46CFR 176.25-1 (a) OLD "T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 27 March 2025
Resolution: Third-party technician arrived the following day to repair pin hole leak. Vessel owner submitted photo evidence of repairs; weld is satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 March 2025
Resolved
Vessels that operate beyond three miles from the coastline must have an approved EPIRB installed in a float free arrangement. Hydrostatic release unit and EPIRB battery were found to be expired. Renew EPIRB and hydrostatic release prior to moving beyond 3 miles from coastline.
Until deficiency is resolved, routes are restricted to within 3 nautical miles of shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2025
Resolved 26 March 2025
Resolution: Batteries in EPIRB were replaced and a new hydrostatic release was installed. See attached tech report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2025
Resolved
Ring life buoys shall be marked with vessel's name. Ring life buoy on aft weather deck was missing vessel's name.
Cite not in MISLE, below is cite for deficiency.
Cite: 46 CFR 185.30-5 (c) OLD "T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 26 March 2025
Resolution: Vessel owner stenciled the life ring.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 March 2025
Resolved
A vessel must comply with applicable requirements issued by the FCC set forth in 47 CFR Part 80. Vessel's required FCC Safety Radiotelephony certificate was expired.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 26 March 2025
Resolved 26 March 2025
Resolution: Third party technician arrived and issues certificate during MI attendance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in charge Marine Inspection.
During the 31 JAN 2024 Dry Dock / Internal Structural Exam Marine Inspectors observed an open HVAC electrical panel and required operator to install a backing plate on the electrical panel.
Marine Inspectors received notification on 22 MAR 2024 that a temporary plastic bin had been installed to satisfy the above requirement. The material was deemed not suitable for continued usage by Marine Inspectors.
Provide a permanent backing plate to remove the electrical shock hazard for crew members and/or passengers.
46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 12 April 2024
Resolution: Operator provided photo evidence of installed backing plate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2024
Resolved
Remove fuel oil, engine oil, and steering hydraulic fluid buildup from all vessel bilges.
Repair leaking fuel oil valve on STBD main engine and inspect other fuel oil lines for leaks and / or excessive wear.
Install chaffing gear in machinery space as necessary to prevent excessive wear or line punctures.
Relocate survey hoisting gear stowed in rudder compartment.
Repair machinery space watertight bulkhead fittings.
Install backing plate on accommodation space void HVAC electrical panel.
*All Work list items are to be rectified prior to
receiving Dry Dock credit.*
46 CFR 176.15-5 (OLD T)
Action required: 705 - Other - as specified
Resolved 5 February 2024
Resolution: Cleared worklist items 1-5. HVAC backing plate worklist item has been re-issued as a non-worklist CG-835V form requirement within this same activity.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 27 December 2023
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Coast Guard marine inspector found expired alcohol test strips on vessel.
Action required: 705 - Other - as specified
Due 3 January 2024
Resolved 29 December 2023
Resolution: Vessel rep aquired new unexpired alcohol test strips and has placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 April 2023
Resolved
Life floats shall be conspicuously marked with vessels name, marking shall be 1 ½” letters and numbers and shall include number of personal allowed. Vessel’s life-float did not have marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 20 April 2023
Resolution: Labeled properly
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 April 2023
Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use. Water-lights on both life-float and life-ring buoy were not working.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2023
Resolved 20 April 2023
Resolution: Vessel replaced batteries in lights, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2022
Resolved
A vessel must have one or more ring life buoy. Found ring life buoy on board to require new line, proper markings and an operable light.
CITE: 46 CFR 180.70
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2022
Resolution: Vessel rep sent photo of corrected deficiency showing proper markings and light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 March 2022
Resolved
Each life float must be secured to the vessel by a painter and a float free link. The life float was found to have improper painter line, weak link was not attached and not secured to the vessel. Paddles missing. Water light inoperable.
CITE: 46CFR 180.20-1(a), 180.15(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2022
Resolution: Vessel master purchased paddle and replaced painter line.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 April 2020
Resolved
Bilge Alarm in rudder room was OOC. Bilge alarms should have visual and audible functionality from the bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2020
Resolved 28 April 2020
Resolution: All vsl Bildge alarms are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2020
Resolved
Life float is missing paddle and needs serviced due to fraying lines and worn tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2020
Resolved 6 May 2020
Resolution: Life Float Serviced, all SAT.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 23 April 2018
Resolved
Replace hose on fire extinguisher located on the port side of the aft deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 27 April 2018
Resolution: Verified compliance via image.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 April 2018
Resolved
Replace broken waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 27 April 2018
Resolution: Verified compliance via image.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 April 2018
Resolved
Provide updated charts.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 27 April 2018
Resolution: Verified compliance via image.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 April 2018
Resolved
Replace missing clamp for flexible hose located on the port engine exhaust.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 27 April 2018
Resolution: Verified compliance via image.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 January 2007
Resolved
Demonstrate proper operation of bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 January 2007
Resolved
Port aft extinguisher missing service tag.
Due 23 February 2007
Resolved 23 January 2007
Resolution: Replaced with serviced extinguisher.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 January 2007
Resolved
Forward navigation light extinguished.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2007
Resolution: Bulb replaced.
Engineering › Bilge Water Management System › Piping
Issued 23 January 2007
Resolved
double hose clamp required on discharge piping.
Due 23 February 2007
Resolved 16 November 2007
Lifesaving › Lifefloat › Float-free Link
Issued 1 February 2006
Resolved
Provide proper weak link for lifefloat.
Condition: Improper Installation
Due 28 February 2006
Resolved 23 January 2007
Engineering › Fuel Oil Service System › Hose
Issued 1 February 2006
Resolved
Replace fuel hoses on generator.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 January 2007
Engineering › Bilge Water Management System › Piping
Issued 1 February 2006
Resolved
Repair bilge piping.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 January 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 February 2006
Resolved
Replace flame screen on fuel vent.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 January 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2006
Resolved
Provide metal wire supports where indicated in engine room.
Condition: Improper Installation
Due 28 February 2006
Resolved 23 January 2007
Construction/Loadline › Hull › Weld
Issued 6 December 2005
Resolved
Make proper repairs to marked pick-up welds in stern compartment/under crew compartment/forepeak.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Engineering › Fuel Oil Service System › Piping
Issued 6 December 2005
Resolved
Renew leaking fuel piping in stern compartment.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Stability › Watertight Integrity › General
Issued 6 December 2005
Resolved
Properly seal all watertight bulkhead penetrations.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 6 December 2005
Resolved
Properly wire bilge alarm float switch under crew compartment. Make proper wiring connections on port and starboard propulsion engine wiring harness.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Engineering › Steering Gear System › Linkage
Issued 6 December 2005
Resolved
Make repairs to jockey bar in way of loose ball joint. Repair steering gear hydraulic leak under console.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Construction/Loadline › Hull › Bracket
Issued 6 December 2005
Resolved
Renew stern tire/fender cables and clamps.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 December 2005
Resolved
Repair fuel leak on generator injector line.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Lifesaving › Lifebuoys
Issued 12 November 2003
Resolved
Provide additional life float for route used. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2003
Resolved 13 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003
Resolved
Speaker wire exposed with unconnected ends. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 12 December 2003
Resolved 13 November 2003
Resolution: Properly wired speaker.
Engineering › Bilge Water Management System › Eductor
Issued 12 November 2003
Resolved
Forepeak reach rod frozen in place. Newly installed, but improper.
Condition: Improper Installation
Due 12 December 2003
Resolved 13 November 2003
Accommodation/Occupational Safety › Ventilation
Issued 12 November 2003
Resolved
Free up engine room vent covers and show proper operation LEGACY COMPONENT DESC: Engine room vent covers frozen.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 13 November 2003
Lifesaving › Lifebuoys
Issued 12 November 2003
Resolved
Renew retro reflective tape on life ring. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Unknown
Due 12 December 2003
Resolved 13 November 2003
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 November 2003
Resolved
Renew port fuel tank vent plug. Missing.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 13 November 2003