FRANCIS CABOT LOWELL is a 2014 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in June 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 9 June 2026.

Built
2014
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1307793
Flag
UNITED STATES
Maury page id
psix-1307793

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2014
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portLOWELL, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

9 June 2026 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8368576
11 June 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8120100
29 October 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8024540
5 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887015
12 June 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7694682
12 May 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7419745
18 August 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036170
22 October 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6838609
13 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6712127
19 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6448231
13 June 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6174254
15 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5907937
27 April 2016 Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5864408

Deficiency record · 14

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2026 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel's ring bouy was missing most of the vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: O/o submitted photograph of lettering on ring life buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025 Resolved
Each ring life buoy must be approved by the Commandant. The grab line on the ring life buoy was deteriorated. Replace grab line to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Objective evidence sent for life buoy, entire life buoy replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Correct stenciling for child-size lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Operator correct actual count of life-jackets to match stenciling.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 June 2025 Resolved
A vessel on a rivers route must carry three hand red flare and three hand orange smoke distress signals. One orange smoke distress signal was missing. Replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Operator sent objective evidence of additional flares.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. A loose wire was found on a battery terminal. Correct to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Objective evidence for dead end wire received.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 02 fire buckets and their associated lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 13 June 2024
Resolution: Vessel representative sent picture of 03 fire buckets for vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 June 2019 Resolved
A vessel of not more than 65 feet in length is not required to carry a rescue boat unless the OCMI determines that the vessel is designed so that the vessel cannot serve as an adequate rescue craft. The freeboard on the vessel does not allow for the recovery of a helpless person. A rescue platform will be an acceptable substitute.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 14 August 2019
Resolution: Received pictures of rescue ladder with platform installed on the vessel.
Lifesaving › Hand Flares › Expired
Issued 19 June 2018 Resolved
Provide 03 red hand flares and 03 orange smoke distress signals OR 06 red hand flares.
Action required: 705 - Other - as specified
Due 26 June 2018
Resolved 28 June 2018
Resolution: Received e-mail from vsl rep showing picture of 6 red flares expiring in 2021.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 June 2018 Resolved
Total persons on board limited to 38. Provide 04 life jackets.
Action required: 705 - Other - as specified
Due 26 June 2018
Resolved 26 June 2018
Resolution: Vessel representative placed additional adult life jackets onboard for a total of 42 adult life jackts.
Lifesaving › Hand Flares › Not on Board
Issued 15 June 2016 Resolved
Provide distress signals as required by 46CFR180.68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 18 July 2016
Resolution: Recieved photo's of new flares on board the vessel.
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 15 June 2016 Resolved
Properly lable and mark life jacket stowage markings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 18 July 2016
Resolution: Recieved photos showing ubdated life jacket stowage markings.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2016 Resolved
Submit a written repair proposal with weld procedures for cropping and renewing, and clad-welding damaged areas on port and starboard pontoons.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 12 May 2016
Resolution: Received and approved written proposal for 6" inserts.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2016 Resolved
Crop and renew and clad weld areas as marked on port and starboard pontoons.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 1 June 2016
Resolution: Verified completed repairs - sat.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2016 Resolved
Complete air pressure test of each affected buoyancy chamber.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 1 June 2016
Resolution: Conducted satisfactory air pressure/soapy water tests of all welded repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.