MAURY USCG vessel records
← All vessels

LUCIA

LUCIA is a 2015 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in March 2026, along with 3 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 18 March 2026.

Built
2015
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7517
1308785
Flag
UNITED STATES
Maury page id
psix-1308785

Documentation record

Registered dimensions (L × B × D)85.4 ft × 30.1 ft × 7.1 ft
Registered tonnagegross 80 / net 54
ITC dimensions (L × B × D)85.4 ft × 30.1 ft × 7.1 ft
ITC tonnagegross 145 / net 79
BuilderSHIPBUILDERS OF WI INC · Manitowoc, WI, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it145 - Convention (Subpart B), Gross Ton
80 - Regulatory (Subpart C or D), Gross Ton
79 - Convention (Subpart B), Net Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

18 March 2026 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8327880
11 March 2025 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8087213
12 December 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8066823
15 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7941908
22 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7916973
30 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7700557
7 March 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7646757
30 March 2022 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7420480
3 March 2021 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7150072
16 April 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6940129
5 December 2019 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6873459
14 March 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6643353
23 September 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6546605
13 June 2018 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6444401
10 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6388499
29 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6381069
1 March 2017 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088596
25 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6077259
9 March 2016 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5831245
19 February 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5820718

Deficiency record · 3

09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 23 September 2018 Resolved
Capacitor on cabin air handling unit control board failed. Make repairs.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2018
Resolved 28 December 2018
Resolution: New board installed, tested and wired properly.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 March 2017 Resolved
Provide alcohol testing strips on board the vessel. Testing strips on board have expired.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 1 March 2017
Resolution: Ordered on the spot to arrive on 07March17 when Coast Guard Marine Inspectors come out to the vessel to conduct MOB and Fire Drills.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 March 2016 Resolved
Prove proper operation of Bilge high level alarm in the tank space per 46 CFR 119.530
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 9 March 2016
Resolution: Float switch was renewed and tested sat. cleared requirement.

Ownership record