MAURY USCG vessel records
← All vessels

TORM DAMINI

TORM DAMINI is a 2014 tank ship. The Coast Guard has recorded 10 inspections since 2016, most recently in July 2025, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: operational control imposed, 25 July 2025.

Built
2014
Last inspected
25 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 July 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9682370
1309422
Flag
DENMARK
Maury page id
psix-1309422

Documentation record

Tonnage as PSIX records it29460 - Convention (Subpart B), Gross Ton
13632 - Convention (Subpart B), Net Ton
60315 - Displacement, Ton
49746 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

25 July 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8194113
8 June 2025 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8180920
14 November 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8031662
13 November 2024 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8033989
30 November 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7831613
3 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7680494
12 October 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7575590
3 July 2020 PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6994398
26 September 2016 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6009458
16 March 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5831188

Deficiency record · 4

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 16 March 2016 Resolved
Protection of the cargo tanks shall be achieved by a fixed IGG system in accordance with FSS Code. IGG shall be capable of maintaining atmosphere in cargo tanks with oxygen content not exceeding 8%. #2 stbd cargo tank found at 8.2%. 74 SOLAS (14) II-2 Reg 4 5.5.1.1; FSS Code Chap 15 2.1.3.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Resolution: Oxygen content brought to within acceptable parameter
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 16 March 2016 Resolved
The IGG shall be designed, constructed and tested in accordance with FSS Code. Required alarms shall be fitted in such a position that they are immediately received by a responsible member of the crew. A tooth pick was used to continuously hold the “acknowledge alarm” button in, so that no alarm would be received. 74 SOLAS (14) II-2 Reg 4 5.5.3.2; FSS Code Chap 15 2.4.3.3.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Resolution: Toothpick removed and crew instructed on importance of receiving alarms
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 16 March 2016 Resolved
Where the emergency source of electrical power is a generator, it shall be provided with an additional source of emergency electrical power and capable of being automatically started in a maximum of 45 seconds. Accumulator batteries were dead and inoperable. 74 SOLAS (14) II-1 Reg 43 3.1.3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Resolution: Dead accumulator batteries replaced with new batteries. Egen tested sat
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 16 March 2016 Resolved
Protection of the cargo tanks shall be achieved by a fixed IGG in accordance with requirements of the FSS Code. The IGG system shall be capable of maintaining a positive pressure at all times. #2 and #3 wing cargo tanks were observed at a dangerously low pressure of 3mbar. 74 SOLAS (14) II-2 Reg 4 5.5.1.1; FSS Code Chap 15 2.1.3.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Resolution: Cargo tanks brought back to within acceptable pressure.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.